I want to search for...

Permit #2006030479

Permit Details

Status: COED

Parcel Id: 07-11-31-7025-00650-0030
CONDITIONED SPACE: 1959 sqft
GARAGE: 491 sqft
OPENED PORCH (WITH ROOF) : 300 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
Total Square Footage: 2800 sqft
Block: 00650
Subdivision: 1228 - SOUTHWEST QUADRANT
Job Phone: (904)363-7626
Location Address: 44 PATRIC DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/28/2006
NOC: RECORDED
Owner: WEEKLEY HOMES

Address

DELAWARE LIMITED PARTNERSHIP

HOUSTON, TX 77055

Address

1111 N POST OAK ROAD

HOUSTON, TX 77055

Lot: 0030
Contracted Stated Job Value: ¤185,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

WEEKLEY HOMES,L.P.
Status Location Address State License Number Phone Fax
CANCEL

448 VICTORIA HILLS DRIVE

DELAND, FL 32724

CBC053082 (Exp: 08/31/2012) (386)775-7206 (386)775-1709

Sub Contractors

CHRISTIAN MASARIK
Status Location Address State License Number Phone Fax
CANCEL

6321 GOMEZ ROAD

ST. AUGUSTINE, FL 32084

EC13001175 (Exp: 08/31/2010) (904)829-2700 (904)829-2751
TYRENE SCOTT
Status Location Address State License Number
CANCEL

9556 HISTORIC KINGS RD ST #306

JACKSONVILLE, FL 32206

CAC035526 (Exp: 09/30/2008)
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918
JEFFREY LUIS CARRASCO
Status Location Address State License Number Phone Fax
CANCEL

665 W. COUNTY ROAD 2006

BUNNELL, FL 32110

CCC1325557 (Exp: 08/31/2010) 904-674-4730 904-268-0471

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 10/03/2006 FINAL APPROVED JMCGOWEN
STORMWATER FINAL INSPECTION 09/29/2006 APPROVED - AS NOTED DRANDALL
Note: 24 sf road damage
RESIDENTIAL EARLY POWER 09/13/2006 APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
RESIDENTIAL EARLY POWER 09/12/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: NEED TO TIGHTEN ACORN NUT ON GROUND ROD.NEED TO CAP PANCAKE IN MTR.BTH.
UTILITY COMPANY FINAL 09/11/2006 APPROVED MBACON
DRIVEWAY 08/28/2006 APPROVED DRANDALL
INSULATION INSPECTION 08/04/2006 APPROVED JHINDMAN
Note: THIS IS A REINSPECTION
INSULATION INSPECTION 08/03/2006 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Missing firestop in multiple locations. Strap nmc every 4.5 ft. where not supported. remove nmc from housing of recessed cans. Do not staple nmc on edge if has to be stapled flat. Use approved straps for nmc on exterior walls. Recheck nail plates.
INSULATION INSPECTION 08/02/2006 Disapproved -FEE REQUIRED KSAMPICO
Note: No pressure on plumbing. Firestop double wall at entry closet/master bath.
INSULATION INSPECTION 07/28/2006 CANCELLED BY APPLICANT CMINI
ALL ROUGH 07/26/2006 APPROVED - AS NOTED ARITTER
Note: NO PRESSURE ON PLUMBING, CHECK AT INSULATION
LATH /BRICK FLASHING 07/26/2006 APPROVED ARITTER
Note:
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/17/2006 APPROVED ARITTER
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/27/2006 Disapproved -FEE REQUIRED RMARVEL
Note: missing strap and tapcons in trusses c-1 thru c-10. strap need tapcons at lanai. no tie down on double truss d-2. need revision or correct on built up post that plan indicates use of syp. no tie down on truss b-7. and the jack next to it needs to be strapped to the bearing wall. not the built out wall. missing 2 2x8 raised beam per plan.
LINTEL 05/25/2006 APPROVED CMINI
Note: THIS IS A REINSPECTION
LINTEL 05/24/2006 Disapproved -FEE REQUIRED ARITTER
Note: No plans in box
FOUNDATION SURVEY APPROVED BY STORMWATER 05/09/2006 APPROVED WKINELL
FIRST ROUGH PLUMBING INSPECTION 04/21/2006 CANCELLED BY APPLICANT PGALLMANN
MONOLITHIC SLAB INSPECTION/SLAB 04/21/2006 APPROVED - AS NOTED PGALLMANN
Note: FURNISH COMPACTION REPORT FOR FOOTINGS AS NOTED SUBSEQUENT TO THE INSPECTION OF 4-19-06.
MONOLITHIC SLAB INSPECTION/SLAB 04/19/2006 Disapproved -FEE REQUIRED ARITTER
Note: no termite notice or compaction test
FIRST ROUGH PLUMBING INSPECTION 04/17/2006 APPROVED ARITTER

Review History

Department Status Date In Date Out
BLD COMPLETE 03/17/2006 03/21/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R.
SW1 COMPLETE 03/14/2006 03/23/2006
Note: Released By: LAPTEKAR
ZON COMPLETE 03/14/2006 03/17/2006
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤292.00 10/11/2006
EARLY POWER INSPECTION ¤40.00 10/11/2006
EARLY POWER INSPECTION ¤40.00 10/11/2006
REINSPECTION FEE ¤40.00 10/11/2006
REINSPECTION FEE ¤40.00 10/11/2006
REINSPECTION FEE ¤40.00 10/11/2006
REINSPECTION FEE ¤40.00 10/11/2006
REINSPECTION FEE ¤40.00 10/11/2006
REINSPECTION FEE ¤40.00 10/11/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 03/28/2006
STORM WATER PERMIT FEES ¤80.00 03/28/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 03/28/2006
FIRE RES IMPACT FEE 4-1-05 ¤173.47 03/28/2006
MECHANICAL FEE ¤148.20 03/28/2006
PERMIT FEE ¤768.30 03/28/2006
PARKS IMPACT FEE 11-2-04 ¤1,120.91 03/28/2006
PLAN CHECK FEE ¤78.80 03/28/2006
PLUMBING FEE ¤148.20 03/28/2006
RADON FEE ¤14.00 03/28/2006
ADMIN FEE ¤20.00 03/28/2006
ARC HOUSE REVIEW ¤125.00 03/28/2006
BUILDING CODE ADMIN FUND ¤14.00 03/28/2006
ELECTRIC FEE ¤148.20 03/28/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,299.59