I want to search for...
Permit #2006030535
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-01060-0140 |
| CONDITIONED SPACE: 2325 sqft |
| GARAGE: 426 sqft |
| OPENED PORCH (WITH ROOF) : 158 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| Total Square Footage: 2959 sqft |
| Block: 01060 |
| Subdivision: - |
| Job Phone: (386) 672-8285 |
| Location Address: 64 BICKFORD DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/10/2006 |
| NOC: RECORDED |
| Applicant name: JOSEPH TODD VANACORE |
| Owner: MCLEISH LEASA |
|
Address 135-05 234TH PL ROSEDALE, NY 11422 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
VANACORE CONSTRUCTION INC.
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
1451 N US HIGHWAY 1 Ormond Beach, FL 32174 |
SUITE 13 Ormond Beach, FL 32174 |
CBC058991 (Exp: 08/31/2024) | (386) 672-8285 |
Sub Contractors
TRENT MIHALIC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P.O. BOX 606 ZELWOOD, FL 32798 |
EC0003150 (Exp: 08/31/2012) | (321) 229-1241 | (386)698-2956 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
NORMAN LEE HUGHES
| Status | Location Address | State License Number | Phone |
| CANCEL |
6429 Fruit Ave Bunnell, FL 32110 |
CFC057334 (Exp: 09/30/2008) | (386) 437-2702 |
GREGORY A HAGEMAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
545 Parque Drive Ormond Beach, FL 32174 |
CCC021394 (Exp: 08/31/2026) | (386) 672-2821 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/31/2006 | FINAL APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/30/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. 90 degree elbow at end of condensate line at condensor to point downward 2. arc sheild at m. bath mirror outlet missing 3. safe-t-switch (garage) not wired 4. jacuzzi motor outlet not mounted 5. check exterior (outlets), gfci's | |||
| STORMWATER FINAL INSPECTION | 08/28/2006 | APPROVED - AS NOTED | DRANDALL |
| Note: THIS IS A REINSPECTION 54 sf road damage...$532 | |||
| STORMWATER FINAL INSPECTION | 08/24/2006 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: remove concrete washout from right adj. property.....remove concrete rocks, as marked, right adj. property.....fix crack in driveway by deck drain.....54 sf road damage | |||
| UTILITY COMPANY FINAL | 08/18/2006 | APPROVED | MMOORE |
| RESIDENTIAL EARLY POWER | 08/17/2006 | APPROVED | MMOORE |
| DRIVEWAY | 07/27/2006 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 06/12/2006 | APPROVED | MMOORE |
| LATH /BRICK FLASHING | 06/07/2006 | APPROVED | PGALLMANN |
| ALL ROUGH | 06/07/2006 | APPROVED | PGALLMANN |
| TEMPORARY POLE | 05/31/2006 | APPROVED | RMARVEL |
| Note: called fpl on 6/1/2006 at 8:30am Damaris | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/30/2006 | APPROVED | ARITTER |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/25/2006 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: INSTALL HEADER STRAPS ON BOTH SIDES OF HEADERS PER PLANS. TAPCON FRONT ENTRANCE ARCH. TIGHTEN ALL THREAD RODS. TAPCON DOOR BUCS 16" ON CENTER AND OFFSET. COMPLETELY NAIL PORCH HANGERS. NAIL HANGER AT MG-7. | |||
| LINTEL | 05/12/2006 | APPROVED | JLEVRAULT |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 05/08/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 05/02/2006 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 04/28/2006 | APPROVED | MMOORE |
Review History
| Department | Status | Date In | Date Out |
| SW1 | HOLD | 07/14/2006 | 07/14/2006 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy. Please submit revised sealed surveys for this property. We check the surveys by comparison to the city's as-built drawings. The elevations at the centerlines of the road perpendicular to the property lines are interpolated in reference to the NATIONAL GEODETIC VERTIVAL DATUM of 1929 (NGVD 1929). By applying the datum shift supplied by the VERTCON utility program for this location, expected elevations are derived relative to the NORTH AMERICAN VERTICAL DATUM of 1988 (NAVD 1988). (Note: VERTCON data is in meters and must be converted to feet by dividing by 0.3048). The derived elevations are in substantial disagreement with the data supplied on the surveys. We take into account that actual elevations may be higher than originally designed by a margin of several inches due to subsequent road paving operations but are not expected to be lower. | |||
| BLD | COMPLETE | 05/23/2006 | 05/25/2006 |
| Note: Released By: LWOODROME Revision: Truss repair | |||
| BLD | COMPLETE | 03/30/2006 | 04/06/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| ZON | COMPLETE | 03/30/2006 | 03/30/2006 |
| Note: Released By: HHERKERT | |||
| ZON | HOLD | 03/24/2006 | 03/24/2006 |
| Note: Held By: HHERKERT landscape plan and tree survey is required | |||
| SW1 | COMPLETE | 03/15/2006 | 03/28/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | HOLD | 03/15/2006 | 03/20/2006 |
| Note: Held By: HHERKERT 1. hold for ARC meeting 3-24-06 2. landscape plan is required 3. tree survey is required | |||
| SW1 | CANCEL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤532.00 | 09/05/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 09/05/2006 |
| REINSPECTION FEE | ¤40.00 | 09/05/2006 |
| REINSPECTION FEE | ¤40.00 | 09/05/2006 |
| REVISION | ¤40.00 | 09/05/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 09/05/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 04/10/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 04/10/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/10/2006 |
| ADMIN FEE | ¤20.00 | 04/10/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 04/10/2006 |
| BUILDING CODE ADMIN FUND | ¤14.80 | 04/10/2006 |
| ELECTRIC FEE | ¤163.20 | 04/10/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 04/10/2006 |
| MECHANICAL FEE | ¤163.20 | 04/10/2006 |
| PERMIT FEE | ¤865.80 | 04/10/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 04/10/2006 |
| PLAN CHECK FEE | ¤88.80 | 04/10/2006 |
| PLUMBING FEE | ¤163.20 | 04/10/2006 |
| RADON FEE | ¤14.80 | 04/10/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,568.69 |