I want to search for...
Permit #2006030882
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7058-00630-0140 |
| CONDITIONED SPACE: 2293 sqft |
| GARAGE: 455 sqft |
| OPENED PORCH (WITH ROOF) : 128 sqft |
| OPENED PORCH (WITH ROOF) : 66 sqft |
| Total Square Footage: 2942 sqft |
| Block: 00630 |
| Subdivision: - |
| Location Address: 13 SELWYN PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/15/2006 |
| NOC: Unknown |
| Applicant name: NO CONTRACTOR OF RECORD |
| Owner: CONNIE L. RAPOLTI |
|
Address PO BOX 9864 DAYTONA BEACH 32120 PALM COAST, FL 32164 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤175,000.00 |
| Job Description: RESIDENTIAL SINGLE FAMILY HOME |
| Type: CN |
Contractor
NO CONTRACTOR OF RECORD
| Status | State License Number |
| CANCEL | CGC1111111 (Exp: 05/20/2016) |
Sub Contractors
STEVE P CONSTANTINO
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
515 HERBERT STREET PORT ORANGE, FL 32129 |
UNIT 1-A PORT ORANGE, FL 32129 |
EC13002346 (Exp: 08/31/2022) | (386)763-9006 | 386-763-5584 |
HOWARD M CARLTON
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1835 B. SOUTH RIDGEWOOD AVE SOUTH DAYTONA, FL 32119 |
CAC058658 (Exp: 09/30/2008) | (386)761-5216 | (386)761-6557 |
ALFERD MITCHUM FUTCH
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1218 San Jose Blvd Holly Hill, FL 32117 |
CFC044175 (Exp: 08/31/2012) | (386) 672-3576 | (386)672-0107 |
DAVID JAMES HART
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1845 JAMES STREET S. DAYTONA, FL 32119 |
CCC1325652 (Exp: 09/30/2008) | (386)767-5800 | (386)767-5695 |
BOB BELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
20 UTILITY DRIVE PALM COAST, FL 32137 |
13878 (Exp: 08/31/2012) | (386)437-4404 | (386)446-2191 |
Inspection History
| Type | Request Date | Result | Inspector |
| GAS ROUGH | 06/29/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: CHECK FOR BOND WIRE @ FINAL | |||
| INSULATION INSPECTION | 06/28/2007 | APPROVED | DROCKWELL |
| Note: | |||
| LATH /BRICK FLASHING | 06/22/2007 | APPROVED | DROCKWELL |
| ALL ROUGH | 06/21/2007 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 06/15/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Item missed at rough but seen at insulation-Insulation board cannot be used as a firestop.Remove insulation behind 1x4.at top perimeter | |||
| ALL ROUGH | 06/08/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Spa tub plumbing not completed/Check cord length to outlet at spa/Check wire bundling throughout | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/12/2006 | APPROVED - AS NOTED | DROCKWELL |
| Note: Letter for truss repair/Strap all trusses not anchored | |||
| LINTEL | 06/16/2006 | APPROVED | DROCKWELL |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 06/15/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 05/22/2006 | APPROVED | DROCKWELL |
| FIRST ROUGH PLUMBING INSPECTION | 05/17/2006 | APPROVED | DROCKWELL |
| PRE DRIVEWAY | |||
| STORMWATER FINAL INSPECTION | |||
| UTILITY COMPANY FINAL | |||
| FINAL COMPLETE BUILDING INSPECTION |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 06/12/2007 | 06/14/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Gas riser diagram submitted. | |||
| BLD | COMPLETE | 08/23/2006 | 08/24/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Truss Repairs 3B, 1MA, 1NA. | |||
| SW1 | COMPLETE | 06/06/2006 | 06/06/2006 |
| Note: Released By: LAPTEKAR received new benchmark | |||
| BLD | COMPLETE | 04/05/2006 | 04/06/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| BLD | HOLD | 03/27/2006 | 03/29/2006 |
| Note: Held By: JJOSEPH 1- PROVIDE DETAILS REGARDING MANUFACTURES SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR FIREPLACE AND CHIMENEY. 2. ALL WORK ASSOCIATED WITH THE INSTALLATION OF GAS PIPING AND EQUIPMENT SHALL BE COMPLETED UNDER A SEPARATE BUILDING PERMIT AND SHALL INCLUDE THE SUBMISSION OF A GAS RISER DIAGRAM INDICATING PIPE SIZES, MATERIAL AND LENGTHS AS WELL AS GAS EQUIPMENT BTU CAPACITIES, TANK SIZE AND LOCATION. | |||
| SW1 | COMPLETE | 03/23/2006 | 04/06/2006 |
| Note: Released By: LAPTEKAR Retrieved topo from the main file | |||
| ZON | COMPLETE | 03/23/2006 | 03/23/2006 |
| Note: Released By: ECOYNE | |||
| URB | COMPLETE | 03/23/2006 | 03/27/2006 |
| Note: Released By: CBENNETT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RENEW PERMIT FEES | ¤40.00 | 01/05/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 05/15/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/15/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 05/15/2006 |
| ADMIN FEE | ¤20.00 | 05/15/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 05/15/2006 |
| BUILDING CODE ADMIN FUND | ¤14.71 | 05/15/2006 |
| ELECTRIC FEE | ¤162.00 | 05/15/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 05/15/2006 |
| MECHANICAL FEE | ¤162.00 | 05/15/2006 |
| PERMIT FEE | ¤858.00 | 05/15/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 05/15/2006 |
| PLAN CHECK FEE | ¤88.00 | 05/15/2006 |
| PLUMBING FEE | ¤162.00 | 05/15/2006 |
| RADON FEE | ¤14.71 | 05/15/2006 |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| RENEW PERMIT FEES | ¤40.00 | |
| REVISION | ¤40.00 | |
| REVISION | ¤40.00 | |
| Fees | Total Due: ¤200.00 | Total Paid: ¤9,869.31 |