I want to search for...
Permit #2006031046
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-00150-0140 |
| CONDITIONED SPACE: 2048 sqft |
| GARAGE: 610 sqft |
| OPENED PORCH (WITH ROOF) : 236 sqft |
| OPENED PORCH (WITH ROOF) : 83 sqft |
| Total Square Footage: 2977 sqft |
| Block: 00150 |
| Subdivision: - |
| Job Phone: (386) 445-7001 |
| Location Address: 29 LYNBROOK DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/20/2006 |
| NOC: RECORDED |
| Applicant name: RICHARD M. ANDERSON |
| Owner: BROWN ALVIN |
|
Address 17 BUD FIELD DRIVE PALM COAST, FL 32137 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤208,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
PALM WEST HOME BUILDERS, INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 Florida Park Drive North Palm Coast, FL 32137 |
CRC054633 (Exp: 08/31/2026) | (386) 445-7001 | (386)446-5941 |
Sub Contractors
JOHN S SMITH
| Status | Location Address | State License Number |
| CANCEL |
P. O. BOX 1160 Bunnell, FL 32110 |
ER0007785 (Exp: 08/31/2015) |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 05/18/2007 | FINAL APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 05/16/2007 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. AT DISCONNECT/ CONDENSOR UNIT / WHITE CONDUCTORS USED AS HOT TO BE MARKED AS SUCH / NO BOX CONNECTOR AT WATER HEATER AND AIR HANDLER 2. MISSING 3 ANCHORS AT BOTTON OF AC UNIT 3. FRONT LEFT OUTLET BOX WITH BLANK COVER / STRAP TO WALL 4. M. BEDROOM CLOSET ON RIGHT / LIGHT GLOCE TO BE 12" TO EDGE OF SHELF 5. NEED SHOWER TRIM OVER TUB 6. GOOF RING / ARC RINGS NEEDED AT ALL OUTLETS AT KITCHEN COUNTER TOPS | |||
| UTILITY COMPANY FINAL | 05/10/2007 | APPROVED | TSCHWEERS |
| Note: Richie called in inspection | |||
| STORMWATER FINAL INSPECTION | 05/01/2007 | APPROVED - AS NOTED | DRANDALL |
| Note: 90 sf road $820 | |||
| RESIDENTIAL EARLY POWER | 04/24/2007 | APPROVED | LHITES |
| Note: CALLED FPL 4/24 | |||
| DRIVEWAY | 03/28/2007 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 11/16/2006 | APPROVED | MMOORE |
| ALL ROUGH | 11/02/2006 | APPROVED | MMOORE |
| LATH /BRICK FLASHING | 10/06/2006 | APPROVED | MMOORE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/28/2006 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/26/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION.....1. PLYWOOD FOR ARCHES IN NON-PRESSURE TREATED AND THEREFORE CANNOT BE IN CONTACT WITH CONCRETE BLOCK 2. ENTRY FRAMING/ SHEATHING NOT COMPLETED FOR INSPECTION #354 AS PER LAST NON-COMPLIANCE DATED 9-22-06 | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/22/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. FRAME TOPS OF WINDOW ARCHES 2. FRAME COLUMN BOXES/ ATTACH AT TOP WITH CONNECTORS | |||
| TEMPORARY POLE | 09/07/2006 | APPROVED | PGALLMANN |
| Note: called fpl at 8:29 | |||
| LINTEL | 08/07/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 08/04/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: SEE FLOOR PLAN/ MISSING DOWNCELL (SEE YELLOW) | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 08/03/2006 | APPROVED - AS NOTED | LAPTEKAR |
| Note: change of FFE okay with lot grading plan | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 07/18/2006 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 07/13/2006 | APPROVED | MMOORE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/13/2006 | 04/19/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| ZON | COMPLETE | 04/11/2006 | 04/13/2006 |
| Note: Released By: HHERKERT | |||
| SW1 | COMPLETE | 03/28/2006 | 04/06/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | HOLD | 03/28/2006 | 03/30/2006 |
| Note: Held By: ECOYNE Need landscaping on side facing side street |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤820.00 | 05/18/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 05/18/2007 |
| REINSPECTION FEE | ¤40.00 | 05/18/2007 |
| REINSPECTION FEE | ¤40.00 | 05/18/2007 |
| REINSPECTION FEE | ¤40.00 | 05/18/2007 |
| REINSPECTION FEE | ¤40.00 | 05/18/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 04/20/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/20/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 04/20/2006 |
| ADMIN FEE | ¤20.00 | 04/20/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 04/20/2006 |
| BUILDING CODE ADMIN FUND | ¤14.89 | 04/20/2006 |
| ELECTRIC FEE | ¤155.40 | 04/20/2006 |
| FIRE RES IMPACT FEE 4-1-05 | ¤173.47 | 04/20/2006 |
| MECHANICAL FEE | ¤155.40 | 04/20/2006 |
| PERMIT FEE | ¤815.10 | 04/20/2006 |
| PARKS IMPACT FEE 11-2-04 | ¤1,120.91 | 04/20/2006 |
| PLAN CHECK FEE | ¤83.60 | 04/20/2006 |
| PLUMBING FEE | ¤155.40 | 04/20/2006 |
| RADON FEE | ¤14.89 | 04/20/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,782.57 |