I want to search for...

Permit #2006040017

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-00580-0110
CONDITIONED SPACE: 2604 sqft
GARAGE: 630 sqft
OPENED PORCH (WITH ROOF) : 211 sqft
OPENED PORCH (WITH ROOF) : 76 sqft
Total Square Footage: 3521 sqft
Block: 00580
Subdivision: -
Job Phone: (386)437-1270
Location Address: 82 LANCELOT DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/16/2006
NOC: RECORDED
Applicant name: DARREN MORRIS THOMAS
Owner: ROBERT COBB AND DOREEN D DUNCAN

Address

19 WINFIELD DR.

PALM COAST, FL 32165

Lot: 0110
Contracted Stated Job Value: ¤350,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

CANTERBURY ESTATE HOMES INC.
Status Location Address State License Number Phone Fax
CANCEL

3222 NW 136TH ST

GAINSVILLE, FL 32606

CBC1250201 (Exp: 09/30/2008) (386)437-1270 (386)437-9667

Sub Contractors

DAVID FRANKLIN POWELL
Status Location Address State License Number Phone Fax
INACTIVE

2610 Dobbs Road

St. Augustine, FL 32086

CAC053851 (Exp: 08/31/2026) 904-794-2665 904-794-2329
ALFERD MITCHUM FUTCH
Status Location Address State License Number Phone Fax
CANCEL

1218 San Jose Blvd

Holly Hill, FL 32117

CFC044175 (Exp: 08/31/2012) (386) 672-3576 (386)672-0107
STEPHEN M RENDE
Status Location Address State License Number Phone
CANCEL

22 ALAMANDA DRIVE

ORMOND, FL 32176

CCC058058 (Exp: 08/31/2020) 386-439-7156
RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 1963

Bunnell, FL 32110

ER0011613 (Exp: 08/31/2008) (386) 437-0607 (386)437-1847
BOB BELL
Status Location Address State License Number Phone Fax
CANCEL

20 UTILITY DRIVE

PALM COAST, FL 32137

13878 (Exp: 08/31/2012) (386)437-4404 (386)446-2191

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 06/18/2007 FINAL APPROVED MMOORE
Note: called in by Rugina
GAS FINAL 06/14/2007 APPROVED MMOORE
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 06/08/2007 APPROVED - AS NOTED DRANDALL
Note: 44 sf road damage...$452
UTILITY COMPANY FINAL 05/31/2007 APPROVED TSCHWEERS
GAS FINAL 04/24/2007 CANCELLED BY APPLICANT MMOORE
GAS ROUGH 04/11/2007 Disapproved - NO FEE MMOORE
Note: this inspection is not required...no visible sign of gasline/tank installation...attempted to call Heritage at 11:10 am and no one answers the phone
DRIVEWAY 02/16/2007 APPROVED DRANDALL
INSULATION INSPECTION 01/11/2007 APPROVED MMOORE
LATH /BRICK FLASHING 01/03/2007 APPROVED MMOORE
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 12/29/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. 2 LAYERS OF VAPOR BARRIER REQUIRED UNDER LATH 2. DO NOT STUCCO 3. MUST PASS INSPECTION 4. $ 40.00 FEE
ALL ROUGH 12/21/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
ALL ROUGH 12/20/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. GAS LINE REQUIRES A GAUGE AND PRESSURIZED 2. GAS LINE MOUNTING IN KITCHEN ABOVE THE FLOOR IS NOT STRONG ENOUGH.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/14/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/12/2006 Disapproved -FEE REQUIRED MMOORE
Note: THIS IS A REINSPECTION 1. AGAIN; TAPCON EACH LOOKOUT WITH 2 TAPCONS EACH 2. BLOCKS ADDED FOR STRAP BACKING AT GABLE ENDS TO HAVE GUSSET PLATES (TOP AND BOTTOM)...CHECK TRUSS REPAIR PLANS 3. ADDED BLOCKS FOR GABLE END STRAPPING AT BATHROOM GABLE TO BE FULL LENGTH AND REQUIRE GUSSETS OR...TAPCON STRAPS AND NAIL INTO TRUSS VERTICAL WEBS
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/07/2006 CANCELLED BY APPLICANT MMOORE
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 11/21/2006 Disapproved -FEE REQUIRED MMOORE
Note: THIS IS A REINSPECTION 1. STRAPPING USED AT GABLES STILL NOT NAILED INTO 2X4 FRAMING BUT ONLY INTO PLYWOOD 1. LOOKOUTS / EYEBROWS REQUIRED 2 TAPCONS EACH
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 11/06/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. HGT-3-PLY IN GARAGE AT RIGHT AND LEFT ENDS HAVE A BROKEN ANCHORAGE BLOCK ( ONE IS OBVIOUS ), NEED REVISION 2. GARAGE DORMER STRAPS NOT NAILED INTO FRAMING 3. GARAGE ENTRY DOOR TO HOUSE NEEDS STRAPPING FROM THE HEADER TO THE STUDS 4. 3-PLY-B-5 , EPOXY NOT MIXED IN THE DRILLED HOLE/ LOOSE BOLTS/ NOT EMBEDDED DEEP ENOUGH 5. GROUT TRUSSES WITH STONELESS GROUT 6. FILL CELLS, 1 CELL AT REAR SLIDER 7. FILL CELLS AT TRUSS C1-3-PLY LEFT SIDE OF GARAGE OUTSIDE 8. TAPCON P.T. AT EYEBROWS, MIN. 2 TAPCONS EACH 9. NAIL BUCKETS ABOVE JACUZZI 10. TRUSSES A-5 THRU A-7 NOT ATTACHED AT ENTRY 11. ALL GABLE STRAPS TO NAIL INTO FRAMING NOT OSB 12. ALL EMBEDDED BOLTS AT THE HGT's ARE NOT DRILLED DEEP ENOUGH I CAN TELL THIS BY THE BOLTS BECOMING LOOSE, BOLTS TO BE DRILLED STRAIGHT-IN CHECK SIMPSON CATALOGUE FOR PROPER DEPTH AND BOLT DIAMETER
LINTEL 09/28/2006 APPROVED MMOORE
FOUNDATION SURVEY APPROVED BY STORMWATER 09/27/2006 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 08/18/2006 APPROVED MMOORE
FIRST ROUGH PLUMBING INSPECTION 08/15/2006 APPROVED MMOORE

Review History

Department Status Date In Date Out
ZON HOLD 03/23/2007 03/23/2007
Note: Held By: ECOYNE Need to show setback information on survey for above ground tank
ZON COMPLETE 03/20/2007 03/26/2007
Note: Released By: JGONZALEZ
ZON REJECT 03/15/2007 03/15/2007
Note: Rejected By: ECOYNE REVISION REJECTED - NEED GAS PERMIT - GIVE BACK TO PERMITTING ECOYNE 03/15/07
SW1 HOLD 01/29/2007 01/29/2007
Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are different than we expected. Appears to be referenced to NGVD 1929. Also missing the elevation of a drainage structure at the corner. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised.
SW1 COMPLETE 12/29/2006 12/29/2006
Note: Released By: WKINELL Review plans for addition of circular dw.\\wk
BLD COMPLETE 12/18/2006 12/20/2006
Note: Released By: CCOTE Approved for Release. REVISION: Truss Repair J1, J2.
BLD COMPLETE 05/03/2006 05/04/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R.
BLD HOLD 04/27/2006 04/28/2006
Note: Held By: FREODICA 1. Lintel type/size is not properly addressed from previous comments.
BLD HOLD 04/24/2006 04/24/2006
Note: Held By: FREODICA 1. Provide truss connectors schedule signed & sealed by FL. Registered Design Professional. 2. Indicate on floor plan the specific type/size of lintel over windows/doors, including lanai, entry & garage. 3. Indicate on drawing the construction methods to be used to meet the required separation of garage from house and attic per FRC 2004 section R309.2. 4. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC 204 section 309.1.1. 5. Indicate how attic access will be constructed to comply with FRC 2004 section R309.2.
ZON COMPLETE 04/21/2006 04/24/2006
Note: Released By: HHERKERT
ZON HOLD 04/18/2006 04/19/2006
Note: Held By: HHERKERT 1. rec'd landscape plan 4-18-06. 2. additional plantings are required along the whole side of the structure facing Larkspur Way 3. the elevations are to show banding around the windows and doors and the banding continueing along the whole side of the structure facing Larkspur Way.
SW1 HOLD 04/03/2006 05/04/2006
Note: Held By: LAPTEKAR driveway flair is too close to intersection....
ZON HOLD 04/03/2006 04/05/2006
Note: Held By: ECOYNE 1.Need landscaping on house facing Larkspur Way 2.the banding is to continue along the side of the structure facing Larkspur Way and the windows and door facing Larkspur Way are to be banded also
SW1 COMPLETE 05/09/2006
Note: Released By: LAPTEKAR Received driveway revision from zoning 5/9....will release

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤452.00 06/26/2007
REINSPECTION FEE ¤40.00 06/26/2007
REINSPECTION FEE ¤40.00 06/26/2007
REINSPECTION FEE ¤40.00 06/26/2007
REINSPECTION FEE ¤40.00 06/26/2007
REINSPECTION FEE ¤40.00 06/26/2007
REVISION ¤40.00 06/26/2007
ADDITIONAL FEE ¤40.00 06/26/2007
SW REVISION ¤40.00 06/26/2007
SW REVISION ¤40.00 06/26/2007
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 05/16/2006
ADMIN FEE ¤20.00 05/16/2006
ARC HOUSE REVIEW ¤125.00 05/16/2006
BUILDING CODE ADMIN FUND ¤17.61 05/16/2006
ELECTRIC FEE ¤240.00 05/16/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 05/16/2006
STORM WATER PERMIT FEES ¤80.00 05/16/2006
FIRE IMPACT FEE 4-1-06 ¤179.37 05/16/2006
MECHANICAL FEE ¤240.00 05/16/2006
PERMIT FEE ¤1,365.00 05/16/2006
PARKS IMPACT FEE 4/1/06 ¤1,159.02 05/16/2006
PLAN CHECK FEE ¤140.00 05/16/2006
PLUMBING FEE ¤240.00 05/16/2006
RADON FEE ¤17.61 05/16/2006
Fees Total Due: ¤0.00 Total Paid: ¤11,484.12