I want to search for...
Permit #2006040017
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-00580-0110 |
| CONDITIONED SPACE: 2604 sqft |
| GARAGE: 630 sqft |
| OPENED PORCH (WITH ROOF) : 211 sqft |
| OPENED PORCH (WITH ROOF) : 76 sqft |
| Total Square Footage: 3521 sqft |
| Block: 00580 |
| Subdivision: - |
| Job Phone: (386)437-1270 |
| Location Address: 82 LANCELOT DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/16/2006 |
| NOC: RECORDED |
| Applicant name: DARREN MORRIS THOMAS |
| Owner: ROBERT COBB AND DOREEN D DUNCAN |
|
Address 19 WINFIELD DR. PALM COAST, FL 32165 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
CANTERBURY ESTATE HOMES INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
3222 NW 136TH ST GAINSVILLE, FL 32606 |
CBC1250201 (Exp: 09/30/2008) | (386)437-1270 | (386)437-9667 |
Sub Contractors
DAVID FRANKLIN POWELL
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
2610 Dobbs Road St. Augustine, FL 32086 |
CAC053851 (Exp: 08/31/2026) | 904-794-2665 | 904-794-2329 |
ALFERD MITCHUM FUTCH
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1218 San Jose Blvd Holly Hill, FL 32117 |
CFC044175 (Exp: 08/31/2012) | (386) 672-3576 | (386)672-0107 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P. O. Box 1963 Bunnell, FL 32110 |
ER0011613 (Exp: 08/31/2008) | (386) 437-0607 | (386)437-1847 |
BOB BELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
20 UTILITY DRIVE PALM COAST, FL 32137 |
13878 (Exp: 08/31/2012) | (386)437-4404 | (386)446-2191 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 06/18/2007 | FINAL APPROVED | MMOORE |
| Note: called in by Rugina | |||
| GAS FINAL | 06/14/2007 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 06/08/2007 | APPROVED - AS NOTED | DRANDALL |
| Note: 44 sf road damage...$452 | |||
| UTILITY COMPANY FINAL | 05/31/2007 | APPROVED | TSCHWEERS |
| GAS FINAL | 04/24/2007 | CANCELLED BY APPLICANT | MMOORE |
| GAS ROUGH | 04/11/2007 | Disapproved - NO FEE | MMOORE |
| Note: this inspection is not required...no visible sign of gasline/tank installation...attempted to call Heritage at 11:10 am and no one answers the phone | |||
| DRIVEWAY | 02/16/2007 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 01/11/2007 | APPROVED | MMOORE |
| LATH /BRICK FLASHING | 01/03/2007 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 12/29/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. 2 LAYERS OF VAPOR BARRIER REQUIRED UNDER LATH 2. DO NOT STUCCO 3. MUST PASS INSPECTION 4. $ 40.00 FEE | |||
| ALL ROUGH | 12/21/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 12/20/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. GAS LINE REQUIRES A GAUGE AND PRESSURIZED 2. GAS LINE MOUNTING IN KITCHEN ABOVE THE FLOOR IS NOT STRONG ENOUGH. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/14/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/12/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION 1. AGAIN; TAPCON EACH LOOKOUT WITH 2 TAPCONS EACH 2. BLOCKS ADDED FOR STRAP BACKING AT GABLE ENDS TO HAVE GUSSET PLATES (TOP AND BOTTOM)...CHECK TRUSS REPAIR PLANS 3. ADDED BLOCKS FOR GABLE END STRAPPING AT BATHROOM GABLE TO BE FULL LENGTH AND REQUIRE GUSSETS OR...TAPCON STRAPS AND NAIL INTO TRUSS VERTICAL WEBS | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/07/2006 | CANCELLED BY APPLICANT | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/21/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: THIS IS A REINSPECTION 1. STRAPPING USED AT GABLES STILL NOT NAILED INTO 2X4 FRAMING BUT ONLY INTO PLYWOOD 1. LOOKOUTS / EYEBROWS REQUIRED 2 TAPCONS EACH | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 11/06/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. HGT-3-PLY IN GARAGE AT RIGHT AND LEFT ENDS HAVE A BROKEN ANCHORAGE BLOCK ( ONE IS OBVIOUS ), NEED REVISION 2. GARAGE DORMER STRAPS NOT NAILED INTO FRAMING 3. GARAGE ENTRY DOOR TO HOUSE NEEDS STRAPPING FROM THE HEADER TO THE STUDS 4. 3-PLY-B-5 , EPOXY NOT MIXED IN THE DRILLED HOLE/ LOOSE BOLTS/ NOT EMBEDDED DEEP ENOUGH 5. GROUT TRUSSES WITH STONELESS GROUT 6. FILL CELLS, 1 CELL AT REAR SLIDER 7. FILL CELLS AT TRUSS C1-3-PLY LEFT SIDE OF GARAGE OUTSIDE 8. TAPCON P.T. AT EYEBROWS, MIN. 2 TAPCONS EACH 9. NAIL BUCKETS ABOVE JACUZZI 10. TRUSSES A-5 THRU A-7 NOT ATTACHED AT ENTRY 11. ALL GABLE STRAPS TO NAIL INTO FRAMING NOT OSB 12. ALL EMBEDDED BOLTS AT THE HGT's ARE NOT DRILLED DEEP ENOUGH I CAN TELL THIS BY THE BOLTS BECOMING LOOSE, BOLTS TO BE DRILLED STRAIGHT-IN CHECK SIMPSON CATALOGUE FOR PROPER DEPTH AND BOLT DIAMETER | |||
| LINTEL | 09/28/2006 | APPROVED | MMOORE |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 09/27/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 08/18/2006 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 08/15/2006 | APPROVED | MMOORE |
Review History
| Department | Status | Date In | Date Out |
| ZON | HOLD | 03/23/2007 | 03/23/2007 |
| Note: Held By: ECOYNE Need to show setback information on survey for above ground tank | |||
| ZON | COMPLETE | 03/20/2007 | 03/26/2007 |
| Note: Released By: JGONZALEZ | |||
| ZON | REJECT | 03/15/2007 | 03/15/2007 |
| Note: Rejected By: ECOYNE REVISION REJECTED - NEED GAS PERMIT - GIVE BACK TO PERMITTING ECOYNE 03/15/07 | |||
| SW1 | HOLD | 01/29/2007 | 01/29/2007 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are different than we expected. Appears to be referenced to NGVD 1929. Also missing the elevation of a drainage structure at the corner. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised. | |||
| SW1 | COMPLETE | 12/29/2006 | 12/29/2006 |
| Note: Released By: WKINELL Review plans for addition of circular dw.\\wk | |||
| BLD | COMPLETE | 12/18/2006 | 12/20/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Truss Repair J1, J2. | |||
| BLD | COMPLETE | 05/03/2006 | 05/04/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| BLD | HOLD | 04/27/2006 | 04/28/2006 |
| Note: Held By: FREODICA 1. Lintel type/size is not properly addressed from previous comments. | |||
| BLD | HOLD | 04/24/2006 | 04/24/2006 |
| Note: Held By: FREODICA 1. Provide truss connectors schedule signed & sealed by FL. Registered Design Professional. 2. Indicate on floor plan the specific type/size of lintel over windows/doors, including lanai, entry & garage. 3. Indicate on drawing the construction methods to be used to meet the required separation of garage from house and attic per FRC 2004 section R309.2. 4. Provide detail as to how mechanical unit and ductwork will be constructed to comply with FRC 204 section 309.1.1. 5. Indicate how attic access will be constructed to comply with FRC 2004 section R309.2. | |||
| ZON | COMPLETE | 04/21/2006 | 04/24/2006 |
| Note: Released By: HHERKERT | |||
| ZON | HOLD | 04/18/2006 | 04/19/2006 |
| Note: Held By: HHERKERT 1. rec'd landscape plan 4-18-06. 2. additional plantings are required along the whole side of the structure facing Larkspur Way 3. the elevations are to show banding around the windows and doors and the banding continueing along the whole side of the structure facing Larkspur Way. | |||
| SW1 | HOLD | 04/03/2006 | 05/04/2006 |
| Note: Held By: LAPTEKAR driveway flair is too close to intersection.... | |||
| ZON | HOLD | 04/03/2006 | 04/05/2006 |
| Note: Held By: ECOYNE 1.Need landscaping on house facing Larkspur Way 2.the banding is to continue along the side of the structure facing Larkspur Way and the windows and door facing Larkspur Way are to be banded also | |||
| SW1 | COMPLETE | 05/09/2006 | |
| Note: Released By: LAPTEKAR Received driveway revision from zoning 5/9....will release |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤452.00 | 06/26/2007 |
| REINSPECTION FEE | ¤40.00 | 06/26/2007 |
| REINSPECTION FEE | ¤40.00 | 06/26/2007 |
| REINSPECTION FEE | ¤40.00 | 06/26/2007 |
| REINSPECTION FEE | ¤40.00 | 06/26/2007 |
| REINSPECTION FEE | ¤40.00 | 06/26/2007 |
| REVISION | ¤40.00 | 06/26/2007 |
| ADDITIONAL FEE | ¤40.00 | 06/26/2007 |
| SW REVISION | ¤40.00 | 06/26/2007 |
| SW REVISION | ¤40.00 | 06/26/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 05/16/2006 |
| ADMIN FEE | ¤20.00 | 05/16/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 05/16/2006 |
| BUILDING CODE ADMIN FUND | ¤17.61 | 05/16/2006 |
| ELECTRIC FEE | ¤240.00 | 05/16/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 05/16/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/16/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 05/16/2006 |
| MECHANICAL FEE | ¤240.00 | 05/16/2006 |
| PERMIT FEE | ¤1,365.00 | 05/16/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 05/16/2006 |
| PLAN CHECK FEE | ¤140.00 | 05/16/2006 |
| PLUMBING FEE | ¤240.00 | 05/16/2006 |
| RADON FEE | ¤17.61 | 05/16/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,484.12 |