I want to search for...
Permit #2006040997
Permit Details
Status: COED
| Parcel Id: 07-11-31-7032-00380-0140 |
| CONDITIONED SPACE: 2057 sqft |
| GARAGE: 426 sqft |
| OPENED PORCH (WITH ROOF) : 158 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| Total Square Footage: 2691 sqft |
| Block: 00380 |
| Subdivision: - |
| Job Phone: (386) 672-8285 |
| Location Address: 28 RUSSO DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/19/2006 |
| NOC: RECORDED |
| Applicant name: JOSEPH TODD VANACORE |
| Owner: SALTARES YVONNE |
|
Address 119 MONTGOMERY AVENUE MASTIC, NY 11950 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
VANACORE CONSTRUCTION INC.
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
1451 N US HIGHWAY 1 Ormond Beach, FL 32174 |
SUITE 13 Ormond Beach, FL 32174 |
CBC058991 (Exp: 08/31/2024) | (386) 672-8285 |
Sub Contractors
DANIEL R SHEFFIELD
| Status | Location Address | State License Number | Phone |
| INACTIVE |
1100 Old Haw Creek Road Bunnell, FL 32110 |
EC0003100 (Exp: 08/31/2024) | 386-931-4729 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
NORMAN LEE HUGHES
| Status | Location Address | State License Number | Phone |
| CANCEL |
6429 Fruit Ave Bunnell, FL 32110 |
CFC057334 (Exp: 09/30/2008) | (386) 437-2702 |
GREGORY A HAGEMAN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
545 Parque Drive Ormond Beach, FL 32174 |
CCC021394 (Exp: 08/31/2026) | (386) 672-2821 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 01/05/2007 | FINAL APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 01/04/2007 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: Missing hammer arrestor on dish-washing line. | |||
| STORMWATER FINAL INSPECTION | 01/02/2007 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION 1 / 3 / 07 24 ' FEET OF ROAD DAMAGE = 292 .00 | |||
| STORMWATER FINAL INSPECTION | 12/28/2006 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: 24 sq ft road damage grade swale right so water will drain remove all cans and trash from waterway remove tree brush right that was cut during construction | |||
| UTILITY COMPANY FINAL | 12/19/2006 | APPROVED | MBACON |
| UTILITY COMPANY FINAL | 12/15/2006 | APPROVED | TSCHWEERS |
| DRIVEWAY | 11/20/2006 | APPROVED | GLALIMA |
| RESIDENTIAL EARLY POWER | 11/14/2006 | APPROVED | LHITES |
| INSULATION INSPECTION | 07/21/2006 | APPROVED | PGALLMANN |
| LATH /BRICK FLASHING | 07/17/2006 | APPROVED | KSAMPICO |
| ALL ROUGH | 07/13/2006 | APPROVED | JHINDMAN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/12/2006 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/10/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION.PLAN CALLS FOR MTS12s FOR SUFFICEINT TRUSS TO BEARING WALL TIE DOWN. NEED TO CORRECT OR GET REVISION FOR USE OF H10s,H2.5s | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/29/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: NEED TO SHOW WHERE MIXED TRUSS TIE DOWNS ARE APPROVED. BEARING WALL DETAIL SHOW SP1s AND SP2s NEED REVISIONS FOR USE OF SP4s. | |||
| LINTEL | 06/19/2006 | APPROVED | CMINI |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 06/14/2006 | APPROVED | LAPTEKAR |
| Note: may need to adjust lot grading plan | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 06/07/2006 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 06/06/2006 | APPROVED | JLEVRAULT |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/08/2006 | 05/08/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | HOLD | 04/26/2006 | 05/09/2006 |
| Note: Held By: LAPTEKAR The topo survey needs to use NAVD 1988 datum. | |||
| ZON | COMPLETE | 04/26/2006 | 05/08/2006 |
| Note: Released By: ECOYNE Held By: ECOYNE | |||
| SW1 | COMPLETE | 05/19/2006 | |
| Note: Released By: LAPTEKAR Existing elevations from top of bank to the ditch can nto be changed. Please call stormwater 986-4760 when lot is cleared and the house is staked per DH. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤292.00 | 01/08/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 01/08/2007 |
| REINSPECTION FEE | ¤40.00 | 01/08/2007 |
| REINSPECTION FEE | ¤40.00 | 01/08/2007 |
| REINSPECTION FEE | ¤40.00 | 01/08/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 01/08/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 05/19/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 05/19/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/19/2006 |
| ADMIN FEE | ¤20.00 | 05/19/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 05/19/2006 |
| BUILDING CODE ADMIN FUND | ¤13.46 | 05/19/2006 |
| ELECTRIC FEE | ¤149.40 | 05/19/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 05/19/2006 |
| MECHANICAL FEE | ¤149.40 | 05/19/2006 |
| PERMIT FEE | ¤776.10 | 05/19/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 05/19/2006 |
| PLAN CHECK FEE | ¤79.60 | 05/19/2006 |
| PLUMBING FEE | ¤149.40 | 05/19/2006 |
| RADON FEE | ¤13.46 | 05/19/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,229.72 |