I want to search for...

Permit #2006050240

Permit Details

Status: COED

Parcel Id: 07-11-31-7011-00010-2040
CONDITIONED SPACE: 3342 sqft
GARAGE: 631 sqft
OPENED PORCH (WITH ROOF) : 179 sqft
OPENED PORCH (WITH ROOF) : 37 sqft
Total Square Footage: 4189 sqft
Block: 00010
Subdivision: -
Job Phone: (386)851-7940
Location Address: 24 BELLMORE PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/16/2006
NOC: RECORDED
Applicant name: LISA MARIE STEINER
Owner: MERCEDES HOMES, INC

Address

775 HARLEY STRICKLAND BLVD

ORANGE CITY FL, FL 32763

Lot: 2040
Contracted Stated Job Value: ¤374,945.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MERCEDES HOMES INC.
Status Location Address State License Number Phone Fax
CANCEL

12001 SCIENCE DRIVE #160

ORLANDO, FL 32826

CGC1510145 (Exp: 08/31/2012) (407)272-5591 (407)282-1563

Sub Contractors

STEVEN JAY SMITH
Status Location Address State License Number Phone
INACTIVE

104 West Cedar Avenue

Orange City, FL 32763

EC0001542 (Exp: 08/31/2022) (386)775-7776
EDDIE T PALMATEER
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

2985 ENTERPRISE ROAD

DEBARY, FL 32713

SUITE A

DEBARY, FL 32713

CAC1813533 (Exp: 08/31/2024) (386)668-8651 (386)668-7758
KATRINA ELAINE RIEF-D'ERRICO
Status Location Address State License Number Phone
CANCEL

157 BOULDER ROCK DR

Palm Coast, FL 32137

CFC1425676 (Exp: 09/30/2008) (386)437-4250
LISA MARIE STEINER
Status Location Address State License Number Phone Fax
CANCEL

12001 SCIENCE DRIVE #160

ORLANDO, FL 32826

CGC1510145 (Exp: 08/31/2012) (407)272-5591 (407)282-1563

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 11/20/2006 FINAL APPROVED MMOORE
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 11/17/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. OUTLETS AT KITCHEN NOT TO EXCEED 24" FROM EDGE OF SINK 2. ARC RING MISSING AT MICROWAVE OUTLET 3. FRONT EXTERIOR GFI NOT TRIPPING/ CHECK ALL OTHERS.....LABEL OUTSIDE GFI's AT PANEL 4. AHU IN CLOSET BY KITCHEN / PATCH PLENUM AT COOLANT LINES
STORMWATER FINAL INSPECTION 11/15/2006 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
UTILITY COMPANY FINAL 11/13/2006 APPROVED TSCHWEERS
STORMWATER FINAL INSPECTION 11/13/2006 CANCELLED BY INSPECTOR LAPTEKAR
Note: Final survey submitted was not approved....this inspection cannot be scheduled.
STORMWATER FINAL INSPECTION 11/13/2006 Disapproved -FEE REQUIRED GLALIMA
Note: PLACE SOD IN SWALE AT ROAD , REAR
RESIDENTIAL EARLY POWER 10/18/2006 APPROVED MMOORE
DRIVEWAY 10/11/2006 APPROVED DRANDALL
LATH /BRICK FLASHING 10/04/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 10/03/2006 Disapproved -FEE REQUIRED MMOORE
Note: NOT READY FOR INSPECTION....9:03 A.M.
INSULATION INSPECTION 09/14/2006 APPROVED PGALLMANN
INSULATION INSPECTION 09/13/2006 Disapproved -FEE REQUIRED PGALLMANN
Note: 1) OPEN TO AIR GAPS IN FIRE CAULKING ABOVE MAIN ELECTRIC PANEL. 2) OPEN ENDED 1" FUTURE SMURF CONDUIT @ PANEL EXTENDING INTO ATTIC.
ALL ROUGH 09/11/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
ALL ROUGH 09/07/2006 Disapproved -FEE REQUIRED PGALLMANN
Note: 1) NO WATER PRESSURE. NOTE TEST ALL TUB & SHOWER VALVES ALSO. 2) TWO BATHROOM EXHAUST FANS ARE NOT DUCTED TO OUTSIDE AIR. 3) NO WATER TEST ON ABOVE GROUND WASTE & VENTS.
ALL ROUGH 09/06/2006 CANCELLED BY APPLICANT AIRS WEB
EXTERIOR WALL SHEATHING/SHEAR WALL 08/15/2006 APPROVED JMCGOWEN
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/15/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 08/14/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. TRUSS T2GE SEE TRUSS BOOK PLANS #5 & #7 2. TAOCON EYEBROWS 3. ADDED STRAPS TO TRUSSES TO WRAP OVER TRUSS 4. ATTIC ACCESS NOT FRAMED 5. GABLE X-BRACING GARAGE 6. STRAPS AT FT3's / FRONT OF BLDG. NOT NAILED TO END OF JOISTS 7. HEADER STRAPS/ DINING ROOM ARCH/ KITCHEN ARCHES 8. KITCHEN LEFT OF ARCHED OPENING. FLOOR JOIST FIIB NEEDS A STUD UNDERNEATH 9. OPEN BOX-OUT AT SLIDING DOOR FOR TAPCON INSP. 10. ONLY 3/4 THE WAY THROUGH 1ST FLOOR INSPECTION 11. HOUSE NOT READY FOR INSP.
LINTEL 07/28/2006 APPROVED MMOORE
FOUNDATION SURVEY APPROVED BY STORMWATER 07/27/2006 APPROVED - AS NOTED WKINELL
Note: FFE 1.12 ft higher than proposed. Requested new LGP.\\wk
MONOLITHIC SLAB INSPECTION/SLAB 07/19/2006 APPROVED ARITTER
FIRST ROUGH PLUMBING INSPECTION 07/18/2006 APPROVED MMOORE

Review History

Department Status Date In Date Out
BLD COMPLETE 05/09/2006 05/10/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
ZON COMPLETE 05/09/2006 05/09/2006
Note: Released By: ECOYNE
SW1 COMPLETE 05/05/2006 05/15/2006
Note: Released By: LAPTEKAR
ZON HOLD 05/05/2006 05/05/2006
Note: Held By: DRAMIREZ need right side set back??

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 11/27/2006
REINSPECTION FEE ¤40.00 11/27/2006
REINSPECTION FEE ¤40.00 11/27/2006
REINSPECTION FEE ¤40.00 11/27/2006
REINSPECTION FEE ¤40.00 11/27/2006
REINSPECTION FEE ¤40.00 11/27/2006
STORMWATER REINSPECTION FEE ¤35.00 11/27/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 05/16/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 05/16/2006
STORM WATER PERMIT FEES ¤80.00 05/16/2006
ADMIN FEE ¤20.00 05/16/2006
ARC HOUSE REVIEW ¤125.00 05/16/2006
BUILDING CODE ADMIN FUND ¤20.95 05/16/2006
ELECTRIC FEE ¤255.00 05/16/2006
FIRE IMPACT FEE 4-1-06 ¤179.37 05/16/2006
MECHANICAL FEE ¤255.00 05/16/2006
PERMIT FEE ¤1,462.50 05/16/2006
PARKS IMPACT FEE 4/1/06 ¤1,159.02 05/16/2006
PLAN CHECK FEE ¤150.00 05/16/2006
PLUMBING FEE ¤255.00 05/16/2006
RADON FEE ¤20.95 05/16/2006
Fees Total Due: ¤0.00 Total Paid: ¤11,106.30