I want to search for...
Permit #2006050402
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-01280-0020 |
| CONDITIONED SPACE: 2875 sqft |
| GARAGE: 596 sqft |
| OPENED PORCH (WITH ROOF) : 80 sqft |
| OPENED PORCH (WITH ROOF) : 56 sqft |
| Total Square Footage: 3607 sqft |
| Block: 01280 |
| Subdivision: - |
| Job Phone: (386)597-6809 |
| Location Address: 6 BIDDING PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/23/2006 |
| NOC: RECORDED |
| Owner: WEEKLEY HOMES L.P. |
|
Address 1111 N POST OAK RD HOUSTON, TX 77055 |
|
Address 6221 8TH AVENUE HOUSTON, TX 77055 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤220,000.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
WEEKLEY HOMES,L.P.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
448 VICTORIA HILLS DRIVE DELAND, FL 32724 |
CBC053082 (Exp: 08/31/2012) | (386)775-7206 | (386)775-1709 |
Sub Contractors
CHRISTIAN MASARIK
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6321 GOMEZ ROAD ST. AUGUSTINE, FL 32084 |
EC13001175 (Exp: 08/31/2010) | (904)829-2700 | (904)829-2751 |
TYRENE SCOTT
| Status | Location Address | State License Number |
| CANCEL |
9556 HISTORIC KINGS RD ST #306 JACKSONVILLE, FL 32206 |
CAC035526 (Exp: 09/30/2008) |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
JEFFREY LUIS CARRASCO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
665 W. COUNTY ROAD 2006 BUNNELL, FL 32110 |
CCC1325557 (Exp: 08/31/2010) | 904-674-4730 | 904-268-0471 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 12/13/2006 | FINAL APPROVED | MMOORE |
| STORMWATER FINAL INSPECTION | 12/11/2006 | APPROVED - AS NOTED | DRANDALL |
| Note: THIS IS A REINSPECTION 25 sf road damage | |||
| RESIDENTIAL EARLY POWER | 12/07/2006 | APPROVED | RMARVEL |
| UTILITY COMPANY FINAL | 12/06/2006 | APPROVED | TSCHWEERS |
| STORMWATER FINAL INSPECTION | 12/05/2006 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: remove all trash from left, rear, & right adj. property, thrown in by sub contractors..... marked with blue paint.....25 sf road damage $ 300.00 | |||
| DRIVEWAY | 10/02/2006 | APPROVED | DRANDALL |
| LATH /BRICK FLASHING | 09/07/2006 | APPROVED | JLEVRAULT |
| INSULATION INSPECTION | 08/29/2006 | APPROVED | MMOORE |
| ALL ROUGH | 08/11/2006 | APPROVED | MMOORE |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/08/2006 | APPROVED | MMOORE |
| Note: 1. ITEMS #1 & #2 (FROM 7-21-06) NOT COMPLETED 2. OSB AT BACKWALL NOT FLUSH WITH OSB ABOVE WINDOW | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/21/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. LEFT BEARING WALL / GARAGE TRUSSES BEARING CENTER BETWEEN STUDS ADD A STUD UNDER THESE TRUSSES. 2. OSB OUTSIDE AT REAR OF BUILDING AT BOTTOM NOT NAILED OFFF PER NAIL PATTERN ADD 2X4 BLOCKS NEXT TO FLOOR JOIST NAIL TO FLOOR JOISTS / NAIL OFF - OSB. 3. 2ND FLOOR: NAIL EXTERIOR OFF PER PLAN. 4. 2ND FLOOR: OVER DOOR EXTERIOR WALL (AT ENTRY) NOT CONNECTED TO BLCOK BELOW. 5. 2ND FLOOR: EXTERIOR WALLS LEFT SIDE AND FRONT LEFT CHECK BOTTOM PLATE ATTACHMENT PER PLANS. 6. TAPCON EYEBROWS / GARAGE. | |||
| LINTEL | 06/30/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 06/29/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: NOT READY FOR INSPECTION...9:27 A.M. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 06/28/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 06/15/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 06/14/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: FOOTER DOWELS NOT COMPLETE | |||
| FIRST ROUGH PLUMBING INSPECTION | 06/12/2006 | APPROVED | MMOORE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/17/2006 | 05/17/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | COMPLETE | 05/09/2006 | 05/12/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 05/09/2006 | 05/17/2006 |
| Note: Released By: ECOYNE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤300.00 | 12/20/2006 |
| EARLY POWER INSPECTION | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| REINSPECTION FEE | ¤40.00 | 12/20/2006 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 12/20/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 05/23/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 05/23/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/23/2006 |
| ADMIN FEE | ¤20.00 | 05/23/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 05/23/2006 |
| BUILDING CODE ADMIN FUND | ¤18.04 | 05/23/2006 |
| ELECTRIC FEE | ¤195.00 | 05/23/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 05/23/2006 |
| MECHANICAL FEE | ¤195.00 | 05/23/2006 |
| PERMIT FEE | ¤1,072.50 | 05/23/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 05/23/2006 |
| PLAN CHECK FEE | ¤110.00 | 05/23/2006 |
| PLUMBING FEE | ¤195.00 | 05/23/2006 |
| RADON FEE | ¤18.04 | 05/23/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,710.48 |