I want to search for...
Permit #2006050455
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-01440-0020 |
| CONDITIONED SPACE: 2321 sqft |
| GARAGE: 464 sqft |
| OPENED PORCH (WITH ROOF) : 43 sqft |
| OPENED PORCH (WITH ROOF) : 250 sqft |
| Total Square Footage: 3078 sqft |
| Block: 01440 |
| Subdivision: - |
| Job Phone: (386)445-7156 |
| Location Address: 25 BIG HORNE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/18/2006 |
| NOC: RECORDED |
| Applicant name: JAMES WILLIAM KIRKSEY |
| Owner: MASTERPIECE HOMES |
|
Address 4721 E. MOODY BLVD BUILDING 5 UNIT 504 BUNNELL, FL 32110 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤130,714.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
MASTERPIECE HOMES INC.
| Status | Location Address | Mailing Address | Phone | Fax |
| CANCEL |
4721 E. MOODY BLVD. BUNNELL, FL 32110 |
BLDG. 5 UNIT 504 BUNNELL, FL 32110 |
(386)445-7156 | (386)445-7975 |
Sub Contractors
GLEN STEWART COLE
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
P. O. Box 1677 Palm Coast, FL 32136 |
EC0002522 (Exp: 08/31/2010) | (386) 437-4364 | (386)437-0412 |
MICHAEL DAVID CLARK
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 918 Bunnell, FL 32110 |
CAC044867 (Exp: 09/30/2008) | (386) 437-2001 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
RYSZARD ALOJZY SKLADZIEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 MARKET PLACE UNIT D PALM COAST, FL 32137 |
CCC057546 (Exp: 08/31/2016) | (386)445-7945 | (386)446-3871 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 12/12/2006 | FINAL APPROVED | MMOORE |
| STORMWATER FINAL INSPECTION | 12/08/2006 | APPROVED | DRANDALL |
| UTILITY COMPANY FINAL | 12/06/2006 | APPROVED | TSCHWEERS |
| DRIVEWAY | 10/24/2006 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 10/09/2006 | APPROVED | MMOORE |
| ALL ROUGH | 10/05/2006 | APPROVED | MMOORE |
| LATH /BRICK FLASHING | 09/14/2006 | APPROVED - AS NOTED | PGALLMANN |
| Note: STRUCTURAL SETTLEMENT WAS OBSERVED IN BLOCK WORK OVER POWER BOX LINTEL, ABOVE OVERHEAD GARAGE DOOR. IT APPEARS THE LINTEL IS IN FAILURE. PROVIDE ENGINEER'S LETTER ADDRESSING SAME. CONTRACTOR CAN NOT PLASTER FRONT OF GARAGE, IN ITS ENTIRTY. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/31/2006 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION......1. TAPCON EYEBROWS FOR ALL-ROUGH INSPECTION/ DO NOT COVER EYEBROWS | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/18/2006 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. PAGE S1 (IN YELLOW) BONUS ROOM WINDOW 2. TAPCON EYEBROWS 3. NAIL PATTER / BONUS ROOM BOTTOM PLATE (2 X 4) 4. OK TO ROOF | |||
| LINTEL | 06/28/2006 | APPROVED | MMOORE |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 06/27/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 06/20/2006 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 06/12/2006 | APPROVED | MMOORE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 09/28/2006 | 09/28/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Garage lintel repair. | |||
| BLD | COMPLETE | 05/10/2006 | 05/11/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | COMPLETE | 05/10/2006 | 05/15/2006 |
| Note: Released By: WKINELL | |||
| ZON | COMPLETE | 05/10/2006 | 05/10/2006 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 12/15/2006 |
| REVISION | ¤40.00 | 12/15/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 05/18/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/18/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 05/18/2006 |
| ADMIN FEE | ¤20.00 | 05/18/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 05/18/2006 |
| BUILDING CODE ADMIN FUND | ¤15.39 | 05/18/2006 |
| ELECTRIC FEE | ¤165.00 | 05/18/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 05/18/2006 |
| MECHANICAL FEE | ¤165.00 | 05/18/2006 |
| PERMIT FEE | ¤877.50 | 05/18/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 05/18/2006 |
| PLAN CHECK FEE | ¤90.00 | 05/18/2006 |
| PLUMBING FEE | ¤165.00 | 05/18/2006 |
| RADON FEE | ¤15.39 | 05/18/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,985.18 |