I want to search for...

Permit #2006051039

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-01250-0010
CONDITIONED SPACE: 2163 sqft
GARAGE: 501 sqft
OPENED PORCH (WITH ROOF) : 318 sqft
OPENED PORCH (WITH ROOF) : 67 sqft
Total Square Footage: 3049 sqft
Block: 01250
Subdivision: -
Job Phone: (386) 445-2222
Location Address: 11 BIDDLESON PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/06/2006
NOC: RECORDED
Applicant name: MICHAEL STEPHAN MULLEN
Owner: EDMUND J & IRENE D PETERWAS

Address

507 STALEVICZ LANE

RAHWAY, NJ 07065

Lot: 0010
Contracted Stated Job Value: ¤120,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

TOWN & COUNTRY HOMES
Status Location Address State License Number Phone
ACTIVE

1 Enterprise Drive

Bunnell, FL 32110

CGC049972 (Exp: 08/31/2026) (386) 445-2222

Sub Contractors

STEVEN DUANE DENSLOW
Status Location Address State License Number Phone Fax
CANCEL

400 N. US # 1

Ormond Beach, FL 32174

EC0001678 (Exp: 08/31/2012) (386) 672-8494 (386)673-7856
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
DENNIS GENE GAINEY
Status Location Address State License Number Phone Fax
INACTIVE

P.O. BOX 1203

Bunnell, FL 32110

CFC046004 (Exp: 08/31/2026) (386) 437-5637 386-437-3012
EUGENIA MAY MILHOLEN
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 2088

Bunnell, FL 32110

CCC048174 (Exp: 08/31/2010) (386) 437-6457 (386)437-6457

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 02/12/2007 FINAL APPROVED MMOORE
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 02/09/2007 Disapproved -FEE REQUIRED MMOORE
Note: 1. AFTER TRIPPING GROUND FAULTS AT THE MAIN PANEL , POWER IS STILL DETECTED BY MULTIMETER IN 3 BEDROOMS. 2. AFTER TURNING-OFF KITCHEN BREAKER AT THE MAIN PANEL , POWER IS STILL DETECTED BY MULTIMETER IN KITCHEN 3. CHECK ALL OF HOUSE
STORMWATER FINAL INSPECTION 02/08/2007 Disapproved -FEE REQUIRED DRANDALL
Note: any road damage caused by utilitys will not be charged to builder remove all trash & construction debris from left, rear, & right adj. property.....22 sf road damage $276.00
UTILITY COMPANY FINAL 02/08/2007 APPROVED DHANEY
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 02/08/2007 APPROVED - AS NOTED DRANDALL
Note: THIS IS A REINSPECTION 22 sf road...$276
UTILITY COMPANY FINAL 02/06/2007 Disapproved - NO FEE TSCHWEERS
Note: FAILED, NO SOD DOWN YET DR from Stormwater received complaint from resident at 1 Biddle Pl that the sewer tap connection for 11 Biddleson PL damaged his swale. This has not been repaired...he was promised this before Christmas. Please note this damage for repair. Thanks,
RESIDENTIAL EARLY POWER 01/11/2007 APPROVED MMOORE
DRIVEWAY 12/22/2006 APPROVED DRANDALL
LATH /BRICK FLASHING 11/30/2006 APPROVED MMOORE
INSULATION INSPECTION 11/21/2006 APPROVED MMOORE
ALL ROUGH 11/14/2006 APPROVED - AS NOTED MMOORE
Note: THIS IS A REINSPECTION....1. SEAL DRYER VENT AT ROOF 2. NO FEE 3. CHECK AT INSULATION INSP.
ALL ROUGH 11/03/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: need 4in. clearance between air ducts. cap off raceway at panel. need bushings on connectors on panel. fire stop needed at top of the double wall. strap nm every 4.5 feet. box out for plumbing and vent in laundry. remove nm cable from housing of recessed cans.
TEMPORARY POLE 10/26/2006 APPROVED MMOORE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/03/2006 APPROVED MMOORE
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/28/2006 Disapproved -FEE REQUIRED MMOORE
Note: 1. NOT READY FOR INSPECTION 2. SPENT 20 MINUTES WITH SUB-CONTRACTOR GOING OVER ITEMS / THIS WAS NOT A FULL INSPECTION
LINTEL 08/25/2006 APPROVED MMOORE
FOUNDATION SURVEY APPROVED BY STORMWATER 08/23/2006 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 08/07/2006 APPROVED MMOORE
FIRST ROUGH PLUMBING INSPECTION 07/31/2006 APPROVED MMOORE

Review History

Department Status Date In Date Out
BLD COMPLETE 09/28/2006 09/29/2006
Note: Released By: CCOTE Approved for Release. REVISION: Truss repair HG03, H16, H17, H11.
BLD COMPLETE 06/02/2006 06/05/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
SW1 COMPLETE 05/26/2006 05/31/2006
Note: Released By: LAPTEKAR
ZON HOLD 05/26/2006 05/30/2006
Note: Held By: HHERKERT hold for ARC meeting 6-2-06
ZON COMPLETE 06/02/2006
Note: Released By: ECOYNE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤276.00 02/14/2007
EARLY POWER INSPECTION ¤40.00 02/14/2007
REINSPECTION FEE ¤40.00 02/14/2007
REINSPECTION FEE ¤40.00 02/14/2007
REINSPECTION FEE ¤40.00 02/14/2007
REVISION ¤40.00 02/14/2007
STORMWATER REINSPECTION FEE ¤35.00 02/14/2007
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 06/06/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 06/06/2006
STORM WATER PERMIT FEES ¤80.00 06/06/2006
ADMIN FEE ¤20.00 06/06/2006
ARC HOUSE REVIEW ¤125.00 06/06/2006
BUILDING CODE ADMIN FUND ¤15.25 06/06/2006
ELECTRIC FEE ¤159.00 06/06/2006
FIRE IMPACT FEE 4-1-06 ¤179.37 06/06/2006
MECHANICAL FEE ¤159.00 06/06/2006
PERMIT FEE ¤838.50 06/06/2006
PARKS IMPACT FEE 4/1/06 ¤1,159.02 06/06/2006
PLAN CHECK FEE ¤86.00 06/06/2006
PLUMBING FEE ¤159.00 06/06/2006
RADON FEE ¤15.25 06/06/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,354.90