I want to search for...
Permit #2006060323
Permit Details
Status: COED
| Parcel Id: 07-11-31-7013-00070-0480 |
| CONDITIONED SPACE: 2056 sqft |
| GARAGE: 547 sqft |
| OPENED PORCH (WITH ROOF) : 178 sqft |
| OPENED PORCH (WITH ROOF) : 27 sqft |
| Total Square Footage: 2808 sqft |
| Block: 00070 |
| Subdivision: - |
| Job Phone: (386)437-5782 |
| Location Address: 65 BREWSTER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/30/2007 |
| NOC: RECORDED |
| Applicant name: SANDRA LEE FRENCH |
| Owner: AFONSO ANTONIO & MARIA H&W |
|
Address 1511 N HIXVILLE ROAD NORTH DARTMOUTH, MA 02747 |
| Lot: 0480 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
SANDEX HOMES
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
27 EGAN DR PALM COAST, FL |
CRC1327302 (Exp: 09/30/2008) | (386)437-5782 | (386)437-5782 |
Sub Contractors
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
BRUCE EDWARD HAWKESWORTH
| Status | Location Address | State License Number | Phone |
| CANCEL |
671 Dara Circle DELTONA, FL 32735 |
CFC053329 (Exp: 09/30/2008) | (386) 228-2784 |
STEVE P CONSTANTINO
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
515 HERBERT STREET PORT ORANGE, FL 32129 |
UNIT 1-A PORT ORANGE, FL 32129 |
EC13002346 (Exp: 08/31/2022) | (386)763-9006 | 386-763-5584 |
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 10/25/2007 | FINAL APPROVED | ACOOPER |
| STORMWATER FINAL INSPECTION | 10/24/2007 | APPROVED - AS NOTED | DRANDALL |
| Note: 24 sf road damage | |||
| UTILITY COMPANY FINAL | 10/24/2007 | APPROVED | TSCHWEERS |
| Note: THIS IS A REINSPECTION 10/24 Gravity ok. | |||
| RESIDENTIAL EARLY POWER | 10/22/2007 | APPROVED | LHITES |
| PRE DRIVEWAY | 10/15/2007 | APPROVED | DRANDALL |
| UTILITY COMPANY FINAL | 10/12/2007 | Disapproved -FEE REQUIRED | TSCHWEERS |
| Note: No Driveway, no final grade or sod yet. | |||
| LATH /BRICK FLASHING | 08/22/2007 | APPROVED | ACOOPER |
| INSULATION INSPECTION | 08/20/2007 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 08/17/2007 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. WIRING TOUCHING RECESSES LIGHTING CANS | |||
| ALL ROUGH | 08/10/2007 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 08/09/2007 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. ALL-THREADS EITHER SIDE OF 4X6 ARE LOOSE IN GARAGE 2. CHECK ALL WINDOWS FOR SCREW ATTACHMENTS AT TOP AND ALSO MISSING SHIMS AT EACH SCREW | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/05/2007 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 06/01/2007 | CANCELLED BY APPLICANT | MMOORE |
| LINTEL | 05/22/2007 | APPROVED | MMOORE |
| Note: Sandra came in to schedule | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 05/21/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 04/10/2007 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 04/05/2007 | APPROVED | MMOORE |
| Note: |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 07/23/2007 | 07/23/2007 |
| Note: Released By: WKINELL New topo survey/LGP received.//wk | |||
| SW1 | HOLD | 07/06/2007 | 07/06/2007 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a discrepancy on the topographic survey. The house number does not match the lot number. Lot #47 is shown instead of Lot# 48. Please submit three signed sealed topographic surveys for this property showing corrections. | |||
| BLD | COMPLETE | 05/14/2007 | 05/15/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Add MBath window, revised truss layout and connectors. | |||
| BLD | COMPLETE | 06/28/2006 | 06/29/2006 |
| Note: Released By: LWOODROME | |||
| ZON | COMPLETE | 06/27/2006 | 06/28/2006 |
| Note: Released By: HHERKERT | |||
| SW1 | COMPLETE | 06/08/2006 | 06/14/2006 |
| Note: Released By: WKINELL | |||
| ZON | HOLD | 06/08/2006 | 06/09/2006 |
| Note: Held By: HHERKERT Address verification is required. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADDITIONAL FEE | ¤40.00 | 10/25/2007 |
| ADDITIONAL FEE | ¤40.00 | 10/25/2007 |
| ENGINEERING ROAD DAMAGE | ¤292.00 | 10/25/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 10/25/2007 |
| REINSPECTION FEE | ¤40.00 | 10/25/2007 |
| REINSPECTION FEE | ¤40.00 | 10/25/2007 |
| REINSPECTION FEE | ¤40.00 | 10/25/2007 |
| REVISION | ¤40.00 | 10/25/2007 |
| SW REVISION | ¤40.00 | 10/25/2007 |
| RADON FEE | ¤14.04 | 03/30/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 03/30/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/30/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/30/2007 |
| PLUMBING FEE | ¤153.00 | 03/30/2007 |
| ADMIN FEE | ¤20.00 | 03/30/2007 |
| BUILDING CODE ADMIN FUND | ¤14.04 | 03/30/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 03/30/2007 |
| ELECTRIC FEE | ¤153.00 | 03/30/2007 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 03/30/2007 |
| MECHANICAL FEE | ¤153.00 | 03/30/2007 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 03/30/2007 |
| PERMIT FEE | ¤799.50 | 03/30/2007 |
| PLAN CHECK FEE | ¤82.00 | 03/30/2007 |
| PLUMBING FEE | (¤153.00) | 02/15/2007 |
| PARKS IMPACT FEE 4/1/06 | (¤1,159.02) | 02/15/2007 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 02/15/2007 |
| PLAN CHECK FEE | ¤82.00 | 02/15/2007 |
| PLAN CHECK FEE | (¤82.00) | 02/15/2007 |
| MECHANICAL FEE | ¤153.00 | 02/15/2007 |
| PERMIT FEE | ¤799.50 | 02/15/2007 |
| PERMIT FEE | (¤799.50) | 02/15/2007 |
| MECHANICAL FEE | (¤153.00) | 02/15/2007 |
| ELECTRIC FEE | ¤153.00 | 02/15/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 02/15/2007 |
| BUILDING CODE ADMIN FUND | ¤14.04 | 02/15/2007 |
| BUILDING CODE ADMIN FUND | (¤14.04) | 02/15/2007 |
| ADMIN FEE | ¤20.00 | 02/15/2007 |
| ADMIN FEE | (¤20.00) | 02/15/2007 |
| ELECTRIC FEE | (¤153.00) | 02/15/2007 |
| ARC HOUSE REVIEW | (¤125.00) | 02/15/2007 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 02/15/2007 |
| FIRE IMPACT FEE 4-1-06 | (¤179.37) | 02/15/2007 |
| PLUMBING FEE | ¤153.00 | 02/15/2007 |
| RADON FEE | ¤14.04 | 02/15/2007 |
| RADON FEE | (¤14.04) | 02/15/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 02/15/2007 |
| SCHOOL BOARD IMPACT FEE RES | (¤3,600.00) | 02/15/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/15/2007 |
| STORM WATER PERMIT FEES | (¤80.00) | 02/15/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 02/15/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | (¤3,248.51) | 02/15/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,392.48 |