I want to search for...
Permit #2006060498
Permit Details
Status: COED
| Parcel Id: 07-11-31-7007-00390-0130 |
| CONDITIONED SPACE: 2431 sqft |
| GARAGE: 469 sqft |
| OPENED PORCH (WITH ROOF) : 328 sqft |
| OPENED PORCH (WITH ROOF) : 68 sqft |
| Total Square Footage: 3296 sqft |
| Block: 00390 |
| Subdivision: - |
| Job Phone: (386)447-4400 |
| Location Address: 22 FRONTIER DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/20/2006 |
| NOC: RECORDED |
| Applicant name: DAVID PAUL CROCKETT |
| Owner: WATERSIDE GROUP INC THE |
|
Address 82 FAXHALL LANE PALM COAST, FL 32137 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤200,000.00 |
| Job Description: RESIDENTIAL SINGLE FAMILY HOME |
| Type: CN |
Contractor
THE WATERSIDE GROUP, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17-B BRELYN PLACE PALM COAST, FL 32137 |
RG0041345 (Exp: 08/31/2010) | (386)447-4400 | (386)447-5800 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
LARRY MILTON HISS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1315 A LPGA BLVD Holly Hill, FL 32117 |
CAC032450 (Exp: 08/31/2018) | (386) 672-8688 | (386)238-8688 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
DAVID PAUL CROCKETT
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17-B BRELYN PLACE PALM COAST, FL 32137 |
RG0041345 (Exp: 08/31/2010) | (386)447-4400 | (386)447-5800 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 03/12/2007 | FINAL APPROVED | JMCGOWEN |
| Note: | |||
| STORMWATER FINAL INSPECTION | 02/13/2007 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 02/08/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: grading fill against fence not allowed, pull back sod regrade & resod as not to touch fence.....runoff shows to flow onto neighboring property right side at a/c unit to front of house, regrade to keep runoff on property | |||
| UTILITY COMPANY FINAL | 02/07/2007 | APPROVED | CBOEHME |
| DRIVEWAY | 12/19/2006 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| DRIVEWAY | 12/18/2006 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: driveway not formed correctly, right side less than 4.5 of concrete over culvert [marked with paint].....clean up at road edge, need a 90* cut , and 5" of concrete at road edge | |||
| INSULATION INSPECTION | 10/04/2006 | APPROVED | LHITES |
| LATH /BRICK FLASHING | 10/02/2006 | APPROVED | LHITES |
| Note: need 2 layers of vapor barrier (for lath) | |||
| ALL ROUGH | 10/02/2006 | APPROVED | LHITES |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/13/2006 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 09/05/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: G-2 not straped, all-thread rod in garage, kit bay-area, master bath, need re-done, 3 missed cells, anchor C-13 @ bearing point, check all threaded rods, repair letter needed on bond beam in master bath vanity @ vent stack, C-20 needs post under bearing point, remove ply-wood @ entry for inspection, mitered window not per plan, mid-point blocking not in @ 10' walls. | |||
| LINTEL | 08/02/2006 | APPROVED | KSAMPICO |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 08/01/2006 | APPROVED | LAPTEKAR |
| TEMPORARY POLE | 07/25/2006 | APPROVED | JGIBSON |
| MONOLITHIC SLAB INSPECTION/SLAB | 07/17/2006 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 07/10/2006 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| SW1 | CANCEL | 11/03/2006 | |
| Note: received new topo survey 11/3 | |||
| SW1 | HOLD | 10/06/2006 | 10/06/2006 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are different than we expected. This survey appears to be relative to NGVD 1929 rather than NAVD 1988. Please submit three signed sealed topographic surveys for this property showing corrected elevations. Note: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised. | |||
| BLD | COMPLETE | 09/07/2006 | 09/11/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Plumbing stack and cut-out of lintel and bond beam is structurally adequate per engineer letter. | |||
| BLD | COMPLETE | 08/07/2006 | 08/09/2006 |
| Note: Released By: CCOTE Approved for Release. Revision: Revised trusses C1, 2, 3, 4, 11. | |||
| BLD | COMPLETE | 07/06/2006 | 07/07/2006 |
| Note: Released By: CCOTE Approved for Release. Revision: Substitute threaded rod for SP1 &2 @ load bearing walls per engineer letter. | |||
| BLD | COMPLETE | 06/15/2006 | 06/16/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | COMPLETE | 06/14/2006 | 06/19/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 06/14/2006 | 06/15/2006 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 03/15/2007 |
| REINSPECTION FEE | ¤40.00 | 03/15/2007 |
| REVISION | ¤40.00 | 03/15/2007 |
| REVISION | ¤40.00 | 03/15/2007 |
| REVISION | ¤40.00 | 03/15/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 03/15/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 03/15/2007 |
| SW REVISION | ¤40.00 | 03/15/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 06/20/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 06/20/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/20/2006 |
| ADMIN FEE | ¤20.00 | 06/20/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 06/20/2006 |
| BUILDING CODE ADMIN FUND | ¤16.48 | 06/20/2006 |
| ELECTRIC FEE | ¤172.20 | 06/20/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 06/20/2006 |
| MECHANICAL FEE | ¤172.20 | 06/20/2006 |
| PERMIT FEE | ¤924.30 | 06/20/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 06/20/2006 |
| PLAN CHECK FEE | ¤94.80 | 06/20/2006 |
| PLUMBING FEE | ¤172.20 | 06/20/2006 |
| RADON FEE | ¤16.48 | 06/20/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,290.56 |