I want to search for...

Permit #2006060498

Permit Details

Status: COED

Parcel Id: 07-11-31-7007-00390-0130
CONDITIONED SPACE: 2431 sqft
GARAGE: 469 sqft
OPENED PORCH (WITH ROOF) : 328 sqft
OPENED PORCH (WITH ROOF) : 68 sqft
Total Square Footage: 3296 sqft
Block: 00390
Subdivision: -
Job Phone: (386)447-4400
Location Address: 22 FRONTIER DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/20/2006
NOC: RECORDED
Applicant name: DAVID PAUL CROCKETT
Owner: WATERSIDE GROUP INC THE

Address

82 FAXHALL LANE

PALM COAST, FL 32137

Lot: 0130
Contracted Stated Job Value: ¤200,000.00
Job Description: RESIDENTIAL SINGLE FAMILY HOME
Type: CN

Contractor

THE WATERSIDE GROUP, INC.
Status Location Address State License Number Phone Fax
CANCEL

17-B BRELYN PLACE

PALM COAST, FL 32137

RG0041345 (Exp: 08/31/2010) (386)447-4400 (386)447-5800

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
LARRY MILTON HISS
Status Location Address State License Number Phone Fax
CANCEL

1315 A LPGA BLVD

Holly Hill, FL 32117

CAC032450 (Exp: 08/31/2018) (386) 672-8688 (386)238-8688
MARTIN JOHN EVANS
Status Location Address State License Number
ACTIVE

14 FORT CAROLINE CT

BUNNELL, FL 32110

CFC057676 (Exp: 08/31/2026)
DAVID PAUL CROCKETT
Status Location Address State License Number Phone Fax
CANCEL

17-B BRELYN PLACE

PALM COAST, FL 32137

RG0041345 (Exp: 08/31/2010) (386)447-4400 (386)447-5800

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 03/12/2007 FINAL APPROVED JMCGOWEN
Note:
STORMWATER FINAL INSPECTION 02/13/2007 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 02/08/2007 Disapproved -FEE REQUIRED DRANDALL
Note: grading fill against fence not allowed, pull back sod regrade & resod as not to touch fence.....runoff shows to flow onto neighboring property right side at a/c unit to front of house, regrade to keep runoff on property
UTILITY COMPANY FINAL 02/07/2007 APPROVED CBOEHME
DRIVEWAY 12/19/2006 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
DRIVEWAY 12/18/2006 Disapproved -FEE REQUIRED DRANDALL
Note: driveway not formed correctly, right side less than 4.5 of concrete over culvert [marked with paint].....clean up at road edge, need a 90* cut , and 5" of concrete at road edge
INSULATION INSPECTION 10/04/2006 APPROVED LHITES
LATH /BRICK FLASHING 10/02/2006 APPROVED LHITES
Note: need 2 layers of vapor barrier (for lath)
ALL ROUGH 10/02/2006 APPROVED LHITES
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/13/2006 APPROVED LHITES
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 09/05/2006 Disapproved -FEE REQUIRED JGIBSON
Note: G-2 not straped, all-thread rod in garage, kit bay-area, master bath, need re-done, 3 missed cells, anchor C-13 @ bearing point, check all threaded rods, repair letter needed on bond beam in master bath vanity @ vent stack, C-20 needs post under bearing point, remove ply-wood @ entry for inspection, mitered window not per plan, mid-point blocking not in @ 10' walls.
LINTEL 08/02/2006 APPROVED KSAMPICO
FOUNDATION SURVEY APPROVED BY STORMWATER 08/01/2006 APPROVED LAPTEKAR
TEMPORARY POLE 07/25/2006 APPROVED JGIBSON
MONOLITHIC SLAB INSPECTION/SLAB 07/17/2006 APPROVED CMINI
FIRST ROUGH PLUMBING INSPECTION 07/10/2006 APPROVED JGIBSON

Review History

Department Status Date In Date Out
SW1 CANCEL 11/03/2006
Note: received new topo survey 11/3
SW1 HOLD 10/06/2006 10/06/2006
Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are different than we expected. This survey appears to be relative to NGVD 1929 rather than NAVD 1988. Please submit three signed sealed topographic surveys for this property showing corrected elevations. Note: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised.
BLD COMPLETE 09/07/2006 09/11/2006
Note: Released By: CCOTE Approved for Release. REVISION: Plumbing stack and cut-out of lintel and bond beam is structurally adequate per engineer letter.
BLD COMPLETE 08/07/2006 08/09/2006
Note: Released By: CCOTE Approved for Release. Revision: Revised trusses C1, 2, 3, 4, 11.
BLD COMPLETE 07/06/2006 07/07/2006
Note: Released By: CCOTE Approved for Release. Revision: Substitute threaded rod for SP1 &2 @ load bearing walls per engineer letter.
BLD COMPLETE 06/15/2006 06/16/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
SW1 COMPLETE 06/14/2006 06/19/2006
Note: Released By: LAPTEKAR
ZON COMPLETE 06/14/2006 06/15/2006
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/15/2007
REINSPECTION FEE ¤40.00 03/15/2007
REVISION ¤40.00 03/15/2007
REVISION ¤40.00 03/15/2007
REVISION ¤40.00 03/15/2007
STORMWATER REINSPECTION FEE ¤35.00 03/15/2007
STORMWATER REINSPECTION FEE ¤35.00 03/15/2007
SW REVISION ¤40.00 03/15/2007
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 06/20/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 06/20/2006
STORM WATER PERMIT FEES ¤80.00 06/20/2006
ADMIN FEE ¤20.00 06/20/2006
ARC HOUSE REVIEW ¤125.00 06/20/2006
BUILDING CODE ADMIN FUND ¤16.48 06/20/2006
ELECTRIC FEE ¤172.20 06/20/2006
FIRE IMPACT FEE 4-1-06 ¤179.37 06/20/2006
MECHANICAL FEE ¤172.20 06/20/2006
PERMIT FEE ¤924.30 06/20/2006
PARKS IMPACT FEE 4/1/06 ¤1,159.02 06/20/2006
PLAN CHECK FEE ¤94.80 06/20/2006
PLUMBING FEE ¤172.20 06/20/2006
RADON FEE ¤16.48 06/20/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,290.56