Permit #2006060680
Permit Details
Status: COED
| Parcel Id: 09-12-31-5117-00000-0080 |
| Total Square Footage: 13308 sqft |
| Block: 00000 |
| Subdivision: 2121 - Pinnacles Professional Park |
| Job Phone: (386)677-8736 |
| Location Address: 80 PINNACLES DR |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 09/22/2006 |
| NOC: RECORDED |
| Applicant name: LEONARD MARINACCO |
| Owner: SEMINOLE 100 DEVELOPERS INC |
|
Address 4 INDIAN MOUND COURT FLAGLER BEACH, FL 32136 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤1,125,000.00 |
| Job Description: OFFICE BUILDING # B |
| Type: CN |
Contractor
BOMAR CONSTRUCTION INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
27 S ORCHARD STREET ORMOND BEACH, FL 32174 |
CGC015648 (Exp: 08/31/2022) | (386)677-8736 | (386)677-7726 |
Sub Contractors
BRADLEY S GILES
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 214176 S. DAYTONA, FL 32119 |
EC0001538 (Exp: 08/31/2026) | (386) 767-5895 | (386)767-6260 |
DONALD G MEYER
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Drawer 730008 Ormond Beach, FL 32174 |
CAC039739 (Exp: 08/31/2016) | (386) 253-7774 |
ROBERT V VON KAAS
| Status | Location Address | State License Number | Phone |
| CANCEL |
909 Carswell Avenue Holly Hill, FL 32117 |
CFC057448 (Exp: 08/31/2010) | (386) 253-8222 |
ROBERT HARRIS SIPES
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
515 LPGA BLVD HOLLY HILL, FL 32117 |
CCC057312 (Exp: 08/31/2010) | (386) 252-3377 | (386)257-9490 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 07/27/2007 | FINAL APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION Per Joe | |||
| FINAL COMPLETE BUILDING INSPECTION | 07/26/2007 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: SUPER GIVEN LONG CORRECTION SHEET. | |||
| UTILITY COMMERCIAL FINAL | 07/26/2007 | APPROVED | KKING |
| UTILITY COMPANY FINAL | 07/25/2007 | APPROVED | TSCHWEERS |
| LANDSCAPE FINAL | 07/25/2007 | APPROVED | CBENNETT |
| Note: BOMAR NEEDS TO REMOVE CONCRETE BLOCKS ON THE LEFT AND NEIGHBORING PROPERTY, - LIGUSTROM TREES CHANGED WITH CRAPE MYRTLES ALONG POND UNDER POWER LINES. INSTALL 2 VIBURNUM SHRUBS AROUND BACK FLOW IN FRONT OF BUILDING B-- RELOCATED OAK ALONG BUILDING B TO A CENTER PARKING LOT ISLAND DUE TO UTILITY CONFLICTS-- PLEASE PRUNE AND FIX BROKEN BRANCHES ON TREES. REMOVED THE SOD BEHIND BACK FLOW AND REPLACE WITH PITTOSPURM SHRUBS-- | |||
| STORMWATER FINAL INSPECTION | 07/25/2007 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: This inspection will be handled with the engineering dep.///duplicate | |||
| ENGINEERING FINAL | 07/25/2007 | APPROVED | KKRUGER |
| FIRE FINAL | 07/20/2007 | APPROVED | JLEWIS |
| FIREWALL INSPECTION | 07/18/2007 | APPROVED - AS NOTED | JPATTEE |
| Note: recieved sealed letter from engineer | |||
| INSULATION INSPECTION | 07/13/2007 | APPROVED | PPROVIDER |
| Note: Letter from Bechtol Engineering Re:missed insulation inspection | |||
| H.V.A.C. FINAL | 07/06/2007 | APPROVED | JL |
| PLUMBING FINAL | 07/06/2007 | APPROVED | PGALLMANN |
| ELECTRICAL FINAL | 07/05/2007 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| ELECTRICAL FINAL | 07/02/2007 | Disapproved -FEE REQUIRED | LHITES |
| Note: OUTLETS IN MENS AND WOMENS RESTROOMS NEED TO BE GFCI PROTECTED. WASHER OUTLET SHOULD BE A SINGLE OUTLET. STRAP LFMC AT WATER HEATERS. BLANK OFF UNUSED OUTLET FOR RECIRCULATING PUMP. NEED COVER PLATE FOR SWITCH-OUTLET COMBO | |||
| H.V.A.C. FINAL | 06/22/2007 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: INSTALL SERVICE OUTLET ON ROOF TOP UNIT ON NORTH EAST CORNER OF ROOF. | |||
| SIDEWALK | 06/19/2007 | CANCELLED BY APPLICANT | AIRS WEB |
| SIDEWALK | 06/19/2007 | Disapproved -FEE REQUIRED | DMAY |
| SIDEWALK | 06/18/2007 | CANCELLED BY APPLICANT | AIRS WEB |
| SIDEWALK | 06/17/2007 | APPROVED | DMAY |
| Note: THIS IS A REINSPECTION | |||
| COMMERCIAL POWER INSPECTION | 05/30/2007 | APPROVED | LHITES |
| Note: called fpl 5/30 | |||
| 2ND ROUGH ELECTRICAL | 05/30/2007 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| 2ND ROUGH ELECTRICAL | 05/25/2007 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. BLUE EMT STRAP EVERY 3' 2. STRAP EMT WHERE IT IS ON TOP OF SPRINKLER LINES / SUPPORTS TOO FAR APART / NOT SECURED PROPERLY | |||
| H.V.A.C. ROUGH | 05/25/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: ABOVE CEILING HVAC. | |||
| COMMERCIAL POWER INSPECTION | 05/01/2007 | APPROVED | LHITES |
| Note: CALLED FPL 5/1 | |||
| SECOND ROUGH PLUMBING INSPECTION | 03/28/2007 | APPROVED | JGIBSON |
| Note: | |||
| SECOND ROUGH PLUMBING INSPECTION | 03/15/2007 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: MISSING MANY NAIL PLATES ON WATER AND WASTE AND VENT STACKS, ALSO ISOLATE COPPER LINES @ ALL DROPS, MISSING SHOWER UNIT MUST BE FOR SECOND ROUGH INSPECTION. | |||
| FRAMING | 03/14/2007 | APPROVED | JHINDMAN |
| Note: | |||
| H.V.A.C. ROUGH | 03/08/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: SOUTH HALF OF GROUND FLOOR RETURN AIR AND EXHAUST DUCTWORK. | |||
| 2ND ROUGH ELECTRICAL | 03/06/2007 | APPROVED | RMARVEL |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/12/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: Canopy inspected. | |||
| LINTEL | 12/12/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: PARAPIT | |||
| LINTEL | 12/01/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: TIE BEAM | |||
| LINTEL | 11/16/2006 | APPROVED | JHINDMAN |
| Note: | |||
| LINTEL | 11/15/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: 3rd lift 3RD LIFT SIDES AND REAR | |||
| LINTEL | 11/13/2006 | APPROVED - AS NOTED | DROCKWELL |
| Note: 2nd lift O.K | |||
| LINTEL | 11/09/2006 | APPROVED - AS NOTED | JLEVRAULT |
| Note: FIRST LIFT. | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 11/02/2006 | APPROVED | JHINDMAN |
| Note: | |||
| STEM FOOTING FOUNDATION | 11/01/2006 | APPROVED | JHINDMAN |
| Note: | |||
| FIRST ROUGH PLUMBING INSPECTION | 10/26/2006 | APPROVED | JGIBSON |
| FOOTER | 10/16/2006 | APPROVED | JHINDMAN |
| Note: |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 09/07/2006 | 09/11/2006 |
| Note: Released By: LWOODROME | |||
| BLD | HOLD | 07/24/2006 | 08/14/2006 |
| Note: Held By: LWOODROME PLAN REVIEW COMMENTS: " Clarify the scope of work for this project by removing all sheets, from the plan(s), which do not pertain to Building "B" (sheets marked building "A") and on sheets which show details or schedules for both buildings, X out the details or schedules which do not pertain to Building "B". The removal of sheets and/or the X'ing out of details must be preformed by your representative. Work space will be provided for you to perform this task. " Verify that door hardware complies with the Florida Building Code, section 11-4.13.9 for H. C. accessibility. " Specify a labeled door frame, door and appropriate hardware for door(s) 801A, 800B, 718B and at the electrical room, which are for openings in rated assemblies. " Clarify detail mark 4/A6.01, 0n sheet A3.1, sheet A6.01 is not included in the plan. " Revise and coordinate detail mark(s) on sheet A3.2 to reference the correct detail(s) on sheet A6.3. " Specify, on sheet A4.3, the wall type for the wall(s) between the vestibule and the public restrooms. " Provide fire damper(s) in the 8"X4" return air duct and the 5" round supply duct, where these ducts penetrated the rated wall assembly of vestibule #725. " Revise sanitary and water diagrams to include the drinking fountain(s), shown on the floor plan, in the common lobby. " Relocate electrical panel for Suite 800, to a space with in Suite 800 or otherwise indicate compliance with National Electrical Code, Article 225.35. " Verify adequate working space, per NEC, Article 110.26, at panel(s) located in the closet off corridor #718. " Provide WPGFCI receptacle outlets, on the roof, spaced so that no piece of roof mounted equipment is more than 25' from a receptacle outlet. " Provide receptacle outlet for electric water cooler. " Provide GFCI protection for receptacle outlets, in the therapy room(s), which are with in 6' of a sink. " Provide electrical disconnect(s) at water heater(s). " Provide additional directional exit signs, where corridor #708 meets with corridor #700 and corridor #718. " Provide emergency egress illumination for the public restrooms, x-ray and consult (area). Larry Woodrome, CBO Chief Plans Examiner City of Palm Coast 386-986-3786 | |||
| FI1 | COMPLETE | 06/19/2006 | 07/07/2006 |
| Note: Released By: JPATTEE Held By: JPATTEE Provide design criteria for the automatic fire sprinkler system per FAC 61G15-32 (5) | |||
| FI1 | COMPLETE | 07/24/2006 | |
| Note: Released By: JPATTEE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/27/2007 |
| MISCELLANEOUS | ¤40.00 | 07/17/2007 |
| REINSPECTION FEE | ¤40.00 | 07/16/2007 |
| REINSPECTION FEE | ¤40.00 | 07/16/2007 |
| REINSPECTION FEE | ¤40.00 | 07/16/2007 |
| REINSPECTION FEE | ¤40.00 | 07/16/2007 |
| REINSPECTION FEE | ¤40.00 | 07/16/2007 |
| TRANSPORTATION IMPACT FEE | ¤118,949.43 | 09/22/2006 |
| PERMIT FEE | ¤6,187.50 | 09/22/2006 |
| PLAN CHECK FEE | ¤1,293.75 | 09/22/2006 |
| PLUMBING FEE | ¤705.00 | 09/22/2006 |
| RADON FEE | ¤66.54 | 09/22/2006 |
| ADMIN FEE | ¤20.00 | 09/22/2006 |
| BUILDING CODE ADMIN FUND | ¤66.54 | 09/22/2006 |
| ELECTRIC FEE | ¤705.00 | 09/22/2006 |
| FIRE COMM IMPACT FEE 4-1-05 | ¤6,615.41 | 09/22/2006 |
| FIRE PLANS REVIEW | ¤133.08 | 09/22/2006 |
| MECHANICAL FEE | ¤705.00 | 09/22/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤135,727.25 |