I want to search for...

Permit #2006060685

Permit Details

Status: COED

Parcel Id: 07-11-31-7009-00320-0060
CONDITIONED SPACE: 2409 sqft
GARAGE: 539 sqft
OPENED PORCH (WITH ROOF) : 295 sqft
OPENED PORCH (WITH ROOF) : 70 sqft
Total Square Footage: 3313 sqft
Block: 00320
Subdivision: -
Job Phone: (386)447-4400
Location Address: 87 FELLOWSHIP DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/18/2006
NOC: RECORDED
Applicant name: DAVID PAUL CROCKETT
Owner: J.WELLS INC A FLORIDA CORP. INC

Address

P.O. BOX 350570

PALM COAST, FL 32135

Lot: 0060
Contracted Stated Job Value: ¤225,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

THE WATERSIDE GROUP, INC.
Status Location Address State License Number Phone Fax
CANCEL

17-B BRELYN PLACE

PALM COAST, FL 32137

RG0041345 (Exp: 08/31/2010) (386)447-4400 (386)447-5800

Sub Contractors

MICHAEL G MORELLO JR
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32137

CAC014293 (Exp: 08/31/2014) (386)447-3950 (386)446-4614
DAVID PAUL CROCKETT
Status Location Address State License Number Phone Fax
CANCEL

17B BRELYN PLACE

PALM COAST, FL 32137

RC0041394 (Exp: 08/31/2011) (386)447-4400 (386)447-5800
HEATH EDWARD SANFORD
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575
KURT A UMBACH
Status Location Address State License Number Phone Fax
HOLD

110 Foster Lane

Palm Coast, FL 32137

EC13003356 (Exp: 08/31/2020) (386) 446-3616 (386)446-3548

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 09/04/2009 FINAL APPROVED LHITES
Note: THIS IS A REINSPECTION
RESIDENTIAL EARLY POWER 08/31/2009 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
RESIDENTIAL EARLY POWER 08/27/2009 Disapproved -FEE REQUIRED RMARVEL
Note: REQUESTED BY KC ELECTRIC Inspection Resulted at 8/27/2009 2:48:48 PM PROPERLY TORQUE LUGS AT METER AND RECHECK PANELS. LAND CONDUCTORS FULLY UNDER LUGS. SPA TUB NEEDS TO BE GFCI PROTECTED. OUTSIDE GRIIL NEEDS CONNECTOR OR BUSHING AT CABLE ENTRANCE. REMOVE KINK IN CABLE AT GRILL. ALSO STRAP NM CABLE UNDER GRILL AREA. CLOSET LIGHTS ARE TO CLOSE TO SHELVES. ALL GFCI PROTECTED RECEPTACLES NEED TO BE IDENTIFIED AS SUCH.
FINAL COMPLETE BUILDING INSPECTION 08/11/2009 CANCELLED BY APPLICANT DROCKWELL
Note: 8/11/09 (PA) - LANDSCAPE OK
STORMWATER FINAL INSPECTION 08/10/2009 APPROVED DRANDALL
PRE DRIVEWAY 08/04/2009 APPROVED DRANDALL
Note: called in by Joe 8/4/09
UTILITY COMPANY FINAL 07/23/2009 APPROVED TSCHWEERS
PRE DRIVEWAY 06/19/2009 APPROVED - AS NOTED DRANDALL
Note: Recheck elevations//called contractor
PRE DRIVEWAY 06/17/2009 Disapproved - NO FEE DRANDALL
Note: DW not properly formed. Patch hole in pipe. Need 50% compacted soil and 50% concrete on top.DR.\\wk
INSULATION INSPECTION 04/28/2009 APPROVED LHITES
ALL ROUGH 04/22/2009 APPROVED - AS NOTED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 4/22/2009 12:05:40 PM WIRING TO MASTER BATH TOILET ROOM CEILING LIGHT STILL NOT COMPLETE/NAIL PLATES AT TOP PLATE IN BED HALLWAY AND BEDROOM 3 SPOTS/ BE AWARE THAT SMOKE DETECTOR SHALL NOT BE WITHIN 36```` OF FAN BLADE/STILL NO WATER TEST ON SANITARY PLUMBING.THESE ITEMS MUST BE ADDRESSED BEFORE INSULATION WILL PASS.
FRAMING 04/22/2009 APPROVED DROCKWELL
LATH /BRICK FLASHING 04/03/2009 APPROVED CMINI
H.V.A.C. ROUGH 03/31/2009 CANCELLED BY INSPECTOR DROCKWELL
Note: Inspection Resulted at 3/31/2009 2:27:39 PM ALL ROUGH DONE 3-30
ALL ROUGH 03/30/2009 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 3/30/2009 12:40:40 PM MASTER BEDROOM NOT FRAMED TO PLAN/KITCHEN NOT FRAMED TO PLAN/NO WATER TEST ON SANITARY PLUMBING.MISSING OUTETS IN GARAGE/NO WIRING TO BOXES IN LAUNDRY ROOM AND MASTER TOILET/MISSING NAIL PLATE EVERYWHERE/STRAP WIRING AT PANEL-CHECK BUNDLING-UNUSED OPENING/BOX FILL AT SWITCH DOOR TO PORCH/WIRING NOT TO PLAN IN FAMILY ROOM CEILING AND SUMMER KITHEN/BOND COPPER LINES TO TUB MOTOR-MASTER TUB/MOVE WIRES AWAY FROM RECESSED LIGHTS/COMPLETE WIRING TO DINING CEILING FIXTURE.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/25/2009 APPROVED CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 03/25/2009 APPROVED DROCKWELL
FRAMING 03/25/2009 APPROVED CMINI
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/10/2009 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 3/10/2009 12:11:17 PM PROVIDE ANCHOAGE REQUIREMENTS FOR WINDOW HEADER BUCK EXCEEDING 3/4```` / REMOVE SHINNERS AT ROOF DECK/TRUSS/FIREBLOCK DROP CEILINGS AT OUTSIDE WALL/H151 TRUSS BUCKET NOT TAP-CONNED TO BLOCK LEFT SIDE/RE-STRAP GIRDER GH6/BJ3B NOT ANCHORED TO WALL/PROVIDE SHEERWALL DETAIL/ROOF METALS ARE TO BE INSTALLED BY THIS INSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 02/25/2009 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 2/25/2009 3:08:41 PM BEARING WALL NOT ANCHORED/TRUSSES NOT NAILED INTO GIRDER/MID-POINT BLOCKING NOT DONE/TAP-CON LOOK-OUTS TO BLOCK...NOT READY FOR INSPECTION,INCOMPLETE INSPECTION
LINTEL 01/22/2009 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
LINTEL 01/21/2009 Disapproved -FEE REQUIRED DROCKWELL
Note: requested by contractor Inspection Resulted at 1/21/2009 12:51:29 PM CONTINUE VENT STACK AT MASTER BATH THRU LINTEL OR OUTSIDE WALL.IT IS POSITIONED TO BE POURED SOLID AT JOINT.
PROJECT STATUS INSPECTION 07/09/2008 Disapproved - NO FEE RMARVEL
Note: THIS IS A REINSPECTION PROPERTY WELL MAINTAINED KEPT CLEAN,SEAMS TO BE SAFE.NO CONSTRUCTION WORK DONE SINCE LAST INSPECTION.
PROJECT STATUS INSPECTION 04/03/2008 Disapproved - NO FEE LHITES
Note: THIS IS A REINSPECTION JOB SITE IS CLEAN. 4 SMALL STACKS OF CONCRETE BLOCK. SOME OF EXPOSED REBAR NEEDS TO BE SAFETY CAPPED. EXPOSED PLUMBING WILL NEED TO BE REINSPECTED (1 ST ROUGH)
PROJECT STATUS INSPECTION 10/03/2007 Disapproved - NO FEE CMINI
Note: PROPERTY AT THIS ADDRESS HAS OVER GROWN WEEDS,WOOD PALATE AND SOME UNUSED CONCRETE NOT IN DUMPSTER......DUMPSTER IS IN EASEMENT WITH GARBAGE STICKING OUT OF IT....STRUCTURE IS JUST A SLAB POURED WITH RUSTY REBAR THAT SHOULD HAVE PROTECTION ON TOP OF REBAR OR A BARRIER AROUND SLAB FOR PROTECTION OF PERSONAL INJURY.....OVER ALL PROPERTY NEEDS TO BE CLEANED AND PROTECTED.
FOUNDATION SURVEY APPROVED BY STORMWATER 02/09/2007 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 08/30/2006 APPROVED LHITES
FOOTER 08/30/2006 APPROVED LHITES
FIRST ROUGH PLUMBING INSPECTION 08/22/2006 APPROVED LHITES
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 08/21/2006 Disapproved -FEE REQUIRED LHITES
Note: must have 100 psi min. check for leaks

Review History

Department Status Date In Date Out
ELEC COMPLETE 04/15/2009 04/15/2009
Note: Released By: SKNOPF Approved for Release. Revision: 1. upgraded electrical to 300 amp meter with (2) 150A MCB panelboards.
ELEC HOLD 04/13/2009 04/13/2009
Note: Held By: JMCGOWEN the service load is 239.17 amps please upgrade/revise service riser from 200 amp to a sufficient service to handle added load.
BLD COMPLETE 04/13/2009 04/15/2009
Note: Released By: JMCGOWEN revision - framing changes in master bath, 3rd half bath & Kitchen
BLD COMPLETE 03/24/2009 03/24/2009
Note: Released By: JJOSEPH 2 copies of window specs per asbuilt 2 copies of exterior door specs per as-built 2 copies of garage door specs 2 copies of shingle specs.
BLD COMPLETE 02/26/2009 02/26/2009
Note: Released By: JJOSEPH Revision Changed truss company
ZON COMPLETE 07/06/2006 07/06/2006
Note: Released By: ECOYNE mustard bloom
BLD COMPLETE 07/06/2006 07/07/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
SW1 HOLD 06/19/2006 07/13/2006
Note: Held By: LAPTEKAR Need a lot grading plan with proposed elevations for the existing elevations of the topo survey...including proposed elevations for the culvert inverts and the proposed finished floor elevation. Topo survey needs the benchmark clearly labeled...which power pole?
ZON HOLD 06/19/2006 06/21/2006
Note: Held By: HHERKERT 1. does not meet front setback 2. hold for ARC meeting 6-23-06
ZON HOLD 06/26/2006
Note: Held By: ECOYNE Wall color denied by ARC spoke with Bill Maning 569-6848 will take picture of home at 180 Frontier spoke with Bill Manning color changed to mustard bloom. 07/06/06.
SW1 COMPLETE 07/18/2006
Note: Released By: LAPTEKAR received new topo/lot grading plan

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 09/08/2009
REINSPECTION FEE ¤40.00 09/08/2009
REINSPECTION FEE ¤40.00 08/21/2009
REINSPECTION FEE ¤40.00 08/21/2009
REINSPECTION FEE ¤40.00 08/21/2009
REVISION ¤40.00 08/21/2009
REVISION ¤40.00 08/21/2009
REVISION ¤40.00 08/21/2009
REVISION ¤40.00 08/21/2009
CONTRACTOR CHANGE ¤40.00 08/21/2009
STORMWATER REINSPECTION FEE ¤35.00 08/21/2009
EXTENSION ¤40.00 02/05/2009
REINSPECTION FEE ¤40.00 02/05/2009
CONTRACTOR CHANGE ¤40.00 02/05/2009
RENEW PERMIT FEES ¤40.00 02/05/2009
CONTRACTOR CHANGE ¤40.00 10/15/2008
CONTRACTOR CHANGE ¤40.00 10/15/2008
ADDITIONAL FEE ¤40.00 07/15/2008
REINSPECTION FEE ¤40.00 07/15/2008
RENEW PERMIT FEES ¤40.00 07/15/2008
RENEW PERMIT FEES ¤40.00 07/15/2008
RENEW PERMIT FEES ¤40.00 07/15/2008
RENEW PERMIT FEES ¤40.00 07/15/2008
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 07/18/2006
STORM WATER PERMIT FEES ¤80.00 07/18/2006
ADMIN FEE ¤20.00 07/18/2006
ARC HOUSE REVIEW ¤125.00 07/18/2006
BUILDING CODE ADMIN FUND ¤16.57 07/18/2006
ELECTRIC FEE ¤172.20 07/18/2006
FIRE IMPACT FEE 4-1-06 ¤179.37 07/18/2006
MECHANICAL FEE ¤172.20 07/18/2006
PERMIT FEE ¤924.30 07/18/2006
PARKS IMPACT FEE 4/1/06 ¤1,159.02 07/18/2006
PLAN CHECK FEE ¤94.80 07/18/2006
PLUMBING FEE ¤172.20 07/18/2006
RADON FEE ¤16.57 07/18/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 07/18/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,895.74