I want to search for...
Permit #2006060685
Permit Details
Status: COED
| Parcel Id: 07-11-31-7009-00320-0060 |
| CONDITIONED SPACE: 2409 sqft |
| GARAGE: 539 sqft |
| OPENED PORCH (WITH ROOF) : 295 sqft |
| OPENED PORCH (WITH ROOF) : 70 sqft |
| Total Square Footage: 3313 sqft |
| Block: 00320 |
| Subdivision: - |
| Job Phone: (386)447-4400 |
| Location Address: 87 FELLOWSHIP DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/18/2006 |
| NOC: RECORDED |
| Applicant name: DAVID PAUL CROCKETT |
| Owner: J.WELLS INC A FLORIDA CORP. INC |
|
Address P.O. BOX 350570 PALM COAST, FL 32135 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤225,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
THE WATERSIDE GROUP, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17-B BRELYN PLACE PALM COAST, FL 32137 |
RG0041345 (Exp: 08/31/2010) | (386)447-4400 | (386)447-5800 |
Sub Contractors
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
DAVID PAUL CROCKETT
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17B BRELYN PLACE PALM COAST, FL 32137 |
RC0041394 (Exp: 08/31/2011) | (386)447-4400 | (386)447-5800 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1351 HAZELNUT ST BUNNELL, FL 32110 |
CFC1427527 (Exp: 08/31/2026) | 386-445-2532 | 386-445-5575 |
KURT A UMBACH
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
110 Foster Lane Palm Coast, FL 32137 |
EC13003356 (Exp: 08/31/2020) | (386) 446-3616 | (386)446-3548 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 09/04/2009 | FINAL APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| RESIDENTIAL EARLY POWER | 08/31/2009 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| RESIDENTIAL EARLY POWER | 08/27/2009 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: REQUESTED BY KC ELECTRIC Inspection Resulted at 8/27/2009 2:48:48 PM PROPERLY TORQUE LUGS AT METER AND RECHECK PANELS. LAND CONDUCTORS FULLY UNDER LUGS. SPA TUB NEEDS TO BE GFCI PROTECTED. OUTSIDE GRIIL NEEDS CONNECTOR OR BUSHING AT CABLE ENTRANCE. REMOVE KINK IN CABLE AT GRILL. ALSO STRAP NM CABLE UNDER GRILL AREA. CLOSET LIGHTS ARE TO CLOSE TO SHELVES. ALL GFCI PROTECTED RECEPTACLES NEED TO BE IDENTIFIED AS SUCH. | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/11/2009 | CANCELLED BY APPLICANT | DROCKWELL |
| Note: 8/11/09 (PA) - LANDSCAPE OK | |||
| STORMWATER FINAL INSPECTION | 08/10/2009 | APPROVED | DRANDALL |
| PRE DRIVEWAY | 08/04/2009 | APPROVED | DRANDALL |
| Note: called in by Joe 8/4/09 | |||
| UTILITY COMPANY FINAL | 07/23/2009 | APPROVED | TSCHWEERS |
| PRE DRIVEWAY | 06/19/2009 | APPROVED - AS NOTED | DRANDALL |
| Note: Recheck elevations//called contractor | |||
| PRE DRIVEWAY | 06/17/2009 | Disapproved - NO FEE | DRANDALL |
| Note: DW not properly formed. Patch hole in pipe. Need 50% compacted soil and 50% concrete on top.DR.\\wk | |||
| INSULATION INSPECTION | 04/28/2009 | APPROVED | LHITES |
| ALL ROUGH | 04/22/2009 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/22/2009 12:05:40 PM WIRING TO MASTER BATH TOILET ROOM CEILING LIGHT STILL NOT COMPLETE/NAIL PLATES AT TOP PLATE IN BED HALLWAY AND BEDROOM 3 SPOTS/ BE AWARE THAT SMOKE DETECTOR SHALL NOT BE WITHIN 36```` OF FAN BLADE/STILL NO WATER TEST ON SANITARY PLUMBING.THESE ITEMS MUST BE ADDRESSED BEFORE INSULATION WILL PASS. | |||
| FRAMING | 04/22/2009 | APPROVED | DROCKWELL |
| LATH /BRICK FLASHING | 04/03/2009 | APPROVED | CMINI |
| H.V.A.C. ROUGH | 03/31/2009 | CANCELLED BY INSPECTOR | DROCKWELL |
| Note: Inspection Resulted at 3/31/2009 2:27:39 PM ALL ROUGH DONE 3-30 | |||
| ALL ROUGH | 03/30/2009 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 3/30/2009 12:40:40 PM MASTER BEDROOM NOT FRAMED TO PLAN/KITCHEN NOT FRAMED TO PLAN/NO WATER TEST ON SANITARY PLUMBING.MISSING OUTETS IN GARAGE/NO WIRING TO BOXES IN LAUNDRY ROOM AND MASTER TOILET/MISSING NAIL PLATE EVERYWHERE/STRAP WIRING AT PANEL-CHECK BUNDLING-UNUSED OPENING/BOX FILL AT SWITCH DOOR TO PORCH/WIRING NOT TO PLAN IN FAMILY ROOM CEILING AND SUMMER KITHEN/BOND COPPER LINES TO TUB MOTOR-MASTER TUB/MOVE WIRES AWAY FROM RECESSED LIGHTS/COMPLETE WIRING TO DINING CEILING FIXTURE. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/25/2009 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 03/25/2009 | APPROVED | DROCKWELL |
| FRAMING | 03/25/2009 | APPROVED | CMINI |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/10/2009 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/10/2009 12:11:17 PM PROVIDE ANCHOAGE REQUIREMENTS FOR WINDOW HEADER BUCK EXCEEDING 3/4```` / REMOVE SHINNERS AT ROOF DECK/TRUSS/FIREBLOCK DROP CEILINGS AT OUTSIDE WALL/H151 TRUSS BUCKET NOT TAP-CONNED TO BLOCK LEFT SIDE/RE-STRAP GIRDER GH6/BJ3B NOT ANCHORED TO WALL/PROVIDE SHEERWALL DETAIL/ROOF METALS ARE TO BE INSTALLED BY THIS INSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 02/25/2009 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 2/25/2009 3:08:41 PM BEARING WALL NOT ANCHORED/TRUSSES NOT NAILED INTO GIRDER/MID-POINT BLOCKING NOT DONE/TAP-CON LOOK-OUTS TO BLOCK...NOT READY FOR INSPECTION,INCOMPLETE INSPECTION | |||
| LINTEL | 01/22/2009 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 01/21/2009 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: requested by contractor Inspection Resulted at 1/21/2009 12:51:29 PM CONTINUE VENT STACK AT MASTER BATH THRU LINTEL OR OUTSIDE WALL.IT IS POSITIONED TO BE POURED SOLID AT JOINT. | |||
| PROJECT STATUS INSPECTION | 07/09/2008 | Disapproved - NO FEE | RMARVEL |
| Note: THIS IS A REINSPECTION PROPERTY WELL MAINTAINED KEPT CLEAN,SEAMS TO BE SAFE.NO CONSTRUCTION WORK DONE SINCE LAST INSPECTION. | |||
| PROJECT STATUS INSPECTION | 04/03/2008 | Disapproved - NO FEE | LHITES |
| Note: THIS IS A REINSPECTION JOB SITE IS CLEAN. 4 SMALL STACKS OF CONCRETE BLOCK. SOME OF EXPOSED REBAR NEEDS TO BE SAFETY CAPPED. EXPOSED PLUMBING WILL NEED TO BE REINSPECTED (1 ST ROUGH) | |||
| PROJECT STATUS INSPECTION | 10/03/2007 | Disapproved - NO FEE | CMINI |
| Note: PROPERTY AT THIS ADDRESS HAS OVER GROWN WEEDS,WOOD PALATE AND SOME UNUSED CONCRETE NOT IN DUMPSTER......DUMPSTER IS IN EASEMENT WITH GARBAGE STICKING OUT OF IT....STRUCTURE IS JUST A SLAB POURED WITH RUSTY REBAR THAT SHOULD HAVE PROTECTION ON TOP OF REBAR OR A BARRIER AROUND SLAB FOR PROTECTION OF PERSONAL INJURY.....OVER ALL PROPERTY NEEDS TO BE CLEANED AND PROTECTED. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 02/09/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 08/30/2006 | APPROVED | LHITES |
| FOOTER | 08/30/2006 | APPROVED | LHITES |
| FIRST ROUGH PLUMBING INSPECTION | 08/22/2006 | APPROVED | LHITES |
| Note: THIS IS A REINSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | 08/21/2006 | Disapproved -FEE REQUIRED | LHITES |
| Note: must have 100 psi min. check for leaks |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 04/15/2009 | 04/15/2009 |
| Note: Released By: SKNOPF Approved for Release. Revision: 1. upgraded electrical to 300 amp meter with (2) 150A MCB panelboards. | |||
| ELEC | HOLD | 04/13/2009 | 04/13/2009 |
| Note: Held By: JMCGOWEN the service load is 239.17 amps please upgrade/revise service riser from 200 amp to a sufficient service to handle added load. | |||
| BLD | COMPLETE | 04/13/2009 | 04/15/2009 |
| Note: Released By: JMCGOWEN revision - framing changes in master bath, 3rd half bath & Kitchen | |||
| BLD | COMPLETE | 03/24/2009 | 03/24/2009 |
| Note: Released By: JJOSEPH 2 copies of window specs per asbuilt 2 copies of exterior door specs per as-built 2 copies of garage door specs 2 copies of shingle specs. | |||
| BLD | COMPLETE | 02/26/2009 | 02/26/2009 |
| Note: Released By: JJOSEPH Revision Changed truss company | |||
| ZON | COMPLETE | 07/06/2006 | 07/06/2006 |
| Note: Released By: ECOYNE mustard bloom | |||
| BLD | COMPLETE | 07/06/2006 | 07/07/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | HOLD | 06/19/2006 | 07/13/2006 |
| Note: Held By: LAPTEKAR Need a lot grading plan with proposed elevations for the existing elevations of the topo survey...including proposed elevations for the culvert inverts and the proposed finished floor elevation. Topo survey needs the benchmark clearly labeled...which power pole? | |||
| ZON | HOLD | 06/19/2006 | 06/21/2006 |
| Note: Held By: HHERKERT 1. does not meet front setback 2. hold for ARC meeting 6-23-06 | |||
| ZON | HOLD | 06/26/2006 | |
| Note: Held By: ECOYNE Wall color denied by ARC spoke with Bill Maning 569-6848 will take picture of home at 180 Frontier spoke with Bill Manning color changed to mustard bloom. 07/06/06. | |||
| SW1 | COMPLETE | 07/18/2006 | |
| Note: Released By: LAPTEKAR received new topo/lot grading plan |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 09/08/2009 |
| REINSPECTION FEE | ¤40.00 | 09/08/2009 |
| REINSPECTION FEE | ¤40.00 | 08/21/2009 |
| REINSPECTION FEE | ¤40.00 | 08/21/2009 |
| REINSPECTION FEE | ¤40.00 | 08/21/2009 |
| REVISION | ¤40.00 | 08/21/2009 |
| REVISION | ¤40.00 | 08/21/2009 |
| REVISION | ¤40.00 | 08/21/2009 |
| REVISION | ¤40.00 | 08/21/2009 |
| CONTRACTOR CHANGE | ¤40.00 | 08/21/2009 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 08/21/2009 |
| EXTENSION | ¤40.00 | 02/05/2009 |
| REINSPECTION FEE | ¤40.00 | 02/05/2009 |
| CONTRACTOR CHANGE | ¤40.00 | 02/05/2009 |
| RENEW PERMIT FEES | ¤40.00 | 02/05/2009 |
| CONTRACTOR CHANGE | ¤40.00 | 10/15/2008 |
| CONTRACTOR CHANGE | ¤40.00 | 10/15/2008 |
| ADDITIONAL FEE | ¤40.00 | 07/15/2008 |
| REINSPECTION FEE | ¤40.00 | 07/15/2008 |
| RENEW PERMIT FEES | ¤40.00 | 07/15/2008 |
| RENEW PERMIT FEES | ¤40.00 | 07/15/2008 |
| RENEW PERMIT FEES | ¤40.00 | 07/15/2008 |
| RENEW PERMIT FEES | ¤40.00 | 07/15/2008 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 07/18/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/18/2006 |
| ADMIN FEE | ¤20.00 | 07/18/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 07/18/2006 |
| BUILDING CODE ADMIN FUND | ¤16.57 | 07/18/2006 |
| ELECTRIC FEE | ¤172.20 | 07/18/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 07/18/2006 |
| MECHANICAL FEE | ¤172.20 | 07/18/2006 |
| PERMIT FEE | ¤924.30 | 07/18/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 07/18/2006 |
| PLAN CHECK FEE | ¤94.80 | 07/18/2006 |
| PLUMBING FEE | ¤172.20 | 07/18/2006 |
| RADON FEE | ¤16.57 | 07/18/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 07/18/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,895.74 |