Permit #2006060689
Permit Details
Status: COED
| Total Square Footage: 13308 sqft |
| Subdivision: 2121 - Pinnacles Professional Park |
| Job Phone: (386)677-8736 |
| Location Address: 84 PINNACLES DR |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 08/22/2006 |
| NOC: RECORDED |
| Applicant name: LEONARD MARINACCO |
| Owner: SEMINOLE 100 DEVELOPERS |
|
Address 4 INDIAN MOUND COURT FLAGLER BEACH, FL 32136 |
| Contracted Stated Job Value: ¤1,125,000.00 |
| Job Description: PINNACLES PROFESSIONAL PARK BUILDING # A |
| Type: CN |
Contractor
BOMAR CONSTRUCTION INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
27 S ORCHARD STREET ORMOND BEACH, FL 32174 |
CGC015648 (Exp: 08/31/2022) | (386)677-8736 | (386)677-7726 |
Sub Contractors
BRADLEY S GILES
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 214176 S. DAYTONA, FL 32119 |
EC0001538 (Exp: 08/31/2026) | (386) 767-5895 | (386)767-6260 |
DONALD G MEYER
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Drawer 730008 Ormond Beach, FL 32174 |
CAC039739 (Exp: 08/31/2016) | (386) 253-7774 |
ROBERT V VON KAAS
| Status | Location Address | State License Number | Phone |
| CANCEL |
909 Carswell Avenue Holly Hill, FL 32117 |
CFC057448 (Exp: 08/31/2010) | (386) 253-8222 |
ROBERT HARRIS SIPES
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
515 LPGA BLVD HOLLY HILL, FL 32117 |
CCC057312 (Exp: 08/31/2010) | (386) 252-3377 | (386)257-9490 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 07/27/2007 | FINAL APPROVED | JLEVRAULT |
| UTILITY COMMERCIAL FINAL | 07/26/2007 | CANCELLED BY APPLICANT | BBEMBRY |
| Note: Contractor called this by mistaked - emailed and requested it be removed. | |||
| LANDSCAPE FINAL | 07/26/2007 | APPROVED | CBENNETT |
| Note: FIX SILK SCREEN BEHIND BUILDING A | |||
| UTILITY COMPANY FINAL | 07/25/2007 | APPROVED | TSCHWEERS |
| STORMWATER FINAL INSPECTION | 07/25/2007 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: This inspection will be handled by the engineering dept ///duplicate inspection | |||
| ENGINEERING FINAL | 07/25/2007 | APPROVED | KKRUGER |
| FIRE FINAL | 07/20/2007 | APPROVED | JLEWIS |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 07/17/2007 | CANCELLED BY APPLICANT | JPATTEE |
| UTILITY COMMERCIAL FINAL | 07/17/2007 | APPROVED | DSPENCER |
| INSULATION INSPECTION | 07/13/2007 | APPROVED | PPROVIDER |
| Note: Letter from Bechtol Engineering Re: missed insulation inspection | |||
| PLUMBING FINAL | 07/05/2007 | APPROVED | JLEVRAULT |
| Note: | |||
| ELECTRICAL FINAL | 06/15/2007 | APPROVED | LHITES |
| H.V.A.C. FINAL | 06/15/2007 | APPROVED | JLEVRAULT |
| ALL ROUGH | 05/21/2007 | APPROVED | JMCGOWEN |
| Note: | |||
| H.V.A.C. ROUGH | 05/18/2007 | APPROVED | JLEVRAULT |
| Note: ABOVE CEILING. | |||
| H.V.A.C. ROUGH | 05/16/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NEED TO STRAP DUCTS WHERE THERE IS NOTICABLE SAGGING...NEED TO MOVE PINCHED DUCTS AND ALSO DUCTS THAT ARE SUPPORTED TIGHTLY BY FRAMING MEMBERS. | |||
| COMMERCIAL POWER INSPECTION | 05/01/2007 | APPROVED | LHITES |
| Note: CALLED FPL 5/1 | |||
| 2ND ROUGH ELECTRICAL | 05/01/2007 | APPROVED | LHITES |
| Note: ABOVE CEILING INSPECTION IS OK | |||
| SECOND ROUGH PLUMBING INSPECTION | 04/12/2007 | APPROVED | PGALLMANN |
| Note: | |||
| SIDEWALK | 04/10/2007 | APPROVED | KKRUGER |
| FIREWALL INSPECTION | 03/22/2007 | APPROVED | JPATTEE |
| Note: THIS IS A REINSPECTION | |||
| FIREWALL INSPECTION | 03/15/2007 | Disapproved - NO FEE | JPATTEE |
| 2ND ROUGH ELECTRICAL | 02/13/2007 | APPROVED | RMARVEL |
| SECOND ROUGH PLUMBING INSPECTION | 02/13/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: Provide access for shock arrestors or move to open ceiling area, also add shut-off valves for mop sink in mechanical room | |||
| ALL ROUGH | 02/13/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: this is for framing only other trades were called in seperatly | |||
| H.V.A.C. ROUGH | 02/07/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: EAST SIDE OF BUILDING DUCTWORK. | |||
| H.V.A.C. ROUGH | 01/26/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: PARTIAL DUCTWORK - HILITED AND DATED ON JOB PLANS. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/03/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: canopy only | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/12/2006 | Disapproved - NO FEE | JHINDMAN |
| Note: THIS IS A REINSPECTION CALLED IN IN ERROR | |||
| LINTEL | 11/28/2006 | APPROVED | JHINDMAN |
| LINTEL | 11/20/2006 | APPROVED | JHINDMAN |
| Note: TIE BEAM | |||
| LINTEL | 11/07/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: 3rd lift | |||
| LINTEL | 11/03/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: 2ND LIFT COLUMNS | |||
| LINTEL | 11/02/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: 1ST LIFT | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 10/26/2006 | APPROVED | JHINDMAN |
| FIRST ROUGH PLUMBING INSPECTION | 10/18/2006 | APPROVED | JGIBSON |
| UNDERGROUND ELECTRICAL | 10/18/2006 | APPROVED | RMARVEL |
| STEM FOOTING FOUNDATION | 10/05/2006 | APPROVED | JLEVRAULT |
| Note: asked to put in can't get it in system | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/05/2006 | Disapproved - NO FEE | JLEVRAULT |
| Note: asked to input by joe lervault gentleman called in wrong inspection | |||
| FOOTER | 10/02/2006 | APPROVED | JHINDMAN |
| TEMPORARY POLE | 09/12/2006 | APPROVED | RMARVEL |
| Note: fpl was called at 8:00 am on 9/14/06. Damaris |
Review History
| Department | Status | Date In | Date Out |
| BLD | HOLD | 07/24/2006 | 08/07/2006 |
| Note: Held By: LWOODROME PLAN REVIEW COMMENTS: " Clarify the scope of work for this project by removing all sheets, from the plan(s), which do not pertain to Building "A" (sheets marked building "B") and on sheets which show details or schedules for both buildings, X out the details or schedules which do not pertain to Building "A". The removal of sheets and/or the X'ing out of details must be preformed by your representative, working space will be provided for you to perform this task. " Verify that door hardware complies with the Florida Building Code, section 11-4.13.9 for H.C. accessibility. " Specify a labeled door frame, door and appropriate hardware for the door marked #215B, which is for an opening in a rated assembly. " Clarify detail mark 4/A6.01, on sheet A3.1, sheet A6.01 is not included in the plan. " Revise and coordinate detail mark(s) on sheet A3.2 to reference the correct details(s) on sheet A6.3. " Specify, on sheet A4.1, the wall type for the wall(s) between the vestibule and the restrooms. " Provide fire damper(s) in the 6"X3" restroom exhaust duct, the 8"X6" exhaust duct to EF-5A and in the 12"X12" supply air duct, where these ducts penetrate the conference room's, 1 hour rated walls. " Provide a drinking fountain for each tenant space or in a common area available to all tenants. The drinking fountain(s) must comply with FBC, Chapter 11 for H.C. accessibility. Approved alternatives may be provided per FBC/Plumbing, section 410. " Revise sanitary and water diagrams to reflect added fixture(s), as required. " Provide WPGFCI receptacle outlets, on the roof, spaced so that no piece of roof mounted equipment is more than 25' from a receptacle outlet. " Provide electrical disconnect(s) at water heater(s). " Provide an additional exit light, on the corridor #204 side of the corridor door, near rooms marked "checkout" and "billing". " Provide emergency egress illumination for the public area restrooms. " Provide emergency egress illumination for the waiting room #200. Larry Woodrome, CBO Chief Plans Examiner City of Palm Coast 386-986-3786 | |||
| FI1 | COMPLETE | 06/19/2006 | 07/07/2006 |
| Note: Released By: JPATTEE Held By: JPATTEE Provide design criteria for automatic fire sprinkler system per the FAC 61G15-32 (5) | |||
| FI1 | COMPLETE | 07/24/2006 | |
| Note: Released By: JPATTEE | |||
| BLD | COMPLETE | 08/18/2006 | |
| Note: Released By: LWOODROME |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| MISCELLANEOUS | ¤40.00 | 07/17/2007 |
| REINSPECTION FEE | ¤40.00 | 07/16/2007 |
| TRANSPORTATION IMPACT FEE | ¤118,949.43 | 08/22/2006 |
| PERMIT FEE | ¤6,187.50 | 08/22/2006 |
| PLAN CHECK FEE | ¤1,293.75 | 08/22/2006 |
| PLUMBING FEE | ¤705.00 | 08/22/2006 |
| RADON FEE | ¤66.54 | 08/22/2006 |
| ADMIN FEE | ¤20.00 | 08/22/2006 |
| BUILDING CODE ADMIN FUND | ¤66.54 | 08/22/2006 |
| ELECTRIC FEE | ¤705.00 | 08/22/2006 |
| FIRE COMM IMPACT FEE 4-1-05 | ¤6,615.41 | 08/22/2006 |
| FIRE PLANS REVIEW | ¤133.08 | 08/22/2006 |
| MECHANICAL FEE | ¤705.00 | 08/22/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤135,527.25 |