Permit #2006060689

Permit Details

Status: COED

Total Square Footage: 13308 sqft
Subdivision: 2121 - Pinnacles Professional Park
Job Phone: (386)677-8736
Location Address: 84 PINNACLES DR
Type: BC - BUILDING COMMERCIAL
Issue Date: 08/22/2006
NOC: RECORDED
Applicant name: LEONARD MARINACCO
Owner: SEMINOLE 100 DEVELOPERS

Address

4 INDIAN MOUND COURT

FLAGLER BEACH, FL 32136

Contracted Stated Job Value: ¤1,125,000.00
Job Description: PINNACLES PROFESSIONAL PARK BUILDING # A
Type: CN

Contractor

BOMAR CONSTRUCTION INC
Status Location Address State License Number Phone Fax
INACTIVE

27 S ORCHARD STREET

ORMOND BEACH, FL 32174

CGC015648 (Exp: 08/31/2022) (386)677-8736 (386)677-7726

Sub Contractors

BRADLEY S GILES
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 214176

S. DAYTONA, FL 32119

EC0001538 (Exp: 08/31/2026) (386) 767-5895 (386)767-6260
DONALD G MEYER
Status Location Address State License Number Phone
CANCEL

P. O. Drawer 730008

Ormond Beach, FL 32174

CAC039739 (Exp: 08/31/2016) (386) 253-7774
ROBERT V VON KAAS
Status Location Address State License Number Phone
CANCEL

909 Carswell Avenue

Holly Hill, FL 32117

CFC057448 (Exp: 08/31/2010) (386) 253-8222
ROBERT HARRIS SIPES
Status Location Address State License Number Phone Fax
CANCEL

515 LPGA BLVD

HOLLY HILL, FL 32117

CCC057312 (Exp: 08/31/2010) (386) 252-3377 (386)257-9490

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 07/27/2007 FINAL APPROVED JLEVRAULT
UTILITY COMMERCIAL FINAL 07/26/2007 CANCELLED BY APPLICANT BBEMBRY
Note: Contractor called this by mistaked - emailed and requested it be removed.
LANDSCAPE FINAL 07/26/2007 APPROVED CBENNETT
Note: FIX SILK SCREEN BEHIND BUILDING A
UTILITY COMPANY FINAL 07/25/2007 APPROVED TSCHWEERS
STORMWATER FINAL INSPECTION 07/25/2007 CANCELLED BY INSPECTOR LAPTEKAR
Note: This inspection will be handled by the engineering dept ///duplicate inspection
ENGINEERING FINAL 07/25/2007 APPROVED KKRUGER
FIRE FINAL 07/20/2007 APPROVED JLEWIS
Note: THIS IS A REINSPECTION
FIRE FINAL 07/17/2007 CANCELLED BY APPLICANT JPATTEE
UTILITY COMMERCIAL FINAL 07/17/2007 APPROVED DSPENCER
INSULATION INSPECTION 07/13/2007 APPROVED PPROVIDER
Note: Letter from Bechtol Engineering Re: missed insulation inspection
PLUMBING FINAL 07/05/2007 APPROVED JLEVRAULT
Note:
ELECTRICAL FINAL 06/15/2007 APPROVED LHITES
H.V.A.C. FINAL 06/15/2007 APPROVED JLEVRAULT
ALL ROUGH 05/21/2007 APPROVED JMCGOWEN
Note:
H.V.A.C. ROUGH 05/18/2007 APPROVED JLEVRAULT
Note: ABOVE CEILING.
H.V.A.C. ROUGH 05/16/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: NEED TO STRAP DUCTS WHERE THERE IS NOTICABLE SAGGING...NEED TO MOVE PINCHED DUCTS AND ALSO DUCTS THAT ARE SUPPORTED TIGHTLY BY FRAMING MEMBERS.
COMMERCIAL POWER INSPECTION 05/01/2007 APPROVED LHITES
Note: CALLED FPL 5/1
2ND ROUGH ELECTRICAL 05/01/2007 APPROVED LHITES
Note: ABOVE CEILING INSPECTION IS OK
SECOND ROUGH PLUMBING INSPECTION 04/12/2007 APPROVED PGALLMANN
Note:
SIDEWALK 04/10/2007 APPROVED KKRUGER
FIREWALL INSPECTION 03/22/2007 APPROVED JPATTEE
Note: THIS IS A REINSPECTION
FIREWALL INSPECTION 03/15/2007 Disapproved - NO FEE JPATTEE
2ND ROUGH ELECTRICAL 02/13/2007 APPROVED RMARVEL
SECOND ROUGH PLUMBING INSPECTION 02/13/2007 APPROVED - AS NOTED JGIBSON
Note: Provide access for shock arrestors or move to open ceiling area, also add shut-off valves for mop sink in mechanical room
ALL ROUGH 02/13/2007 APPROVED - AS NOTED JHINDMAN
Note: this is for framing only other trades were called in seperatly
H.V.A.C. ROUGH 02/07/2007 APPROVED - AS NOTED JLEVRAULT
Note: EAST SIDE OF BUILDING DUCTWORK.
H.V.A.C. ROUGH 01/26/2007 APPROVED - AS NOTED JLEVRAULT
Note: PARTIAL DUCTWORK - HILITED AND DATED ON JOB PLANS.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 01/03/2007 APPROVED - AS NOTED JHINDMAN
Note: canopy only
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/12/2006 Disapproved - NO FEE JHINDMAN
Note: THIS IS A REINSPECTION CALLED IN IN ERROR
LINTEL 11/28/2006 APPROVED JHINDMAN
LINTEL 11/20/2006 APPROVED JHINDMAN
Note: TIE BEAM
LINTEL 11/07/2006 APPROVED - AS NOTED JHINDMAN
Note: 3rd lift
LINTEL 11/03/2006 APPROVED - AS NOTED JHINDMAN
Note: 2ND LIFT COLUMNS
LINTEL 11/02/2006 APPROVED - AS NOTED JHINDMAN
Note: 1ST LIFT
MONOLITHIC SLAB INSPECTION/SLAB 10/26/2006 APPROVED JHINDMAN
FIRST ROUGH PLUMBING INSPECTION 10/18/2006 APPROVED JGIBSON
UNDERGROUND ELECTRICAL 10/18/2006 APPROVED RMARVEL
STEM FOOTING FOUNDATION 10/05/2006 APPROVED JLEVRAULT
Note: asked to put in can't get it in system
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 10/05/2006 Disapproved - NO FEE JLEVRAULT
Note: asked to input by joe lervault gentleman called in wrong inspection
FOOTER 10/02/2006 APPROVED JHINDMAN
TEMPORARY POLE 09/12/2006 APPROVED RMARVEL
Note: fpl was called at 8:00 am on 9/14/06. Damaris

Review History

Department Status Date In Date Out
BLD HOLD 07/24/2006 08/07/2006
Note: Held By: LWOODROME PLAN REVIEW COMMENTS: " Clarify the scope of work for this project by removing all sheets, from the plan(s), which do not pertain to Building "A" (sheets marked building "B") and on sheets which show details or schedules for both buildings, X out the details or schedules which do not pertain to Building "A". The removal of sheets and/or the X'ing out of details must be preformed by your representative, working space will be provided for you to perform this task. " Verify that door hardware complies with the Florida Building Code, section 11-4.13.9 for H.C. accessibility. " Specify a labeled door frame, door and appropriate hardware for the door marked #215B, which is for an opening in a rated assembly. " Clarify detail mark 4/A6.01, on sheet A3.1, sheet A6.01 is not included in the plan. " Revise and coordinate detail mark(s) on sheet A3.2 to reference the correct details(s) on sheet A6.3. " Specify, on sheet A4.1, the wall type for the wall(s) between the vestibule and the restrooms. " Provide fire damper(s) in the 6"X3" restroom exhaust duct, the 8"X6" exhaust duct to EF-5A and in the 12"X12" supply air duct, where these ducts penetrate the conference room's, 1 hour rated walls. " Provide a drinking fountain for each tenant space or in a common area available to all tenants. The drinking fountain(s) must comply with FBC, Chapter 11 for H.C. accessibility. Approved alternatives may be provided per FBC/Plumbing, section 410. " Revise sanitary and water diagrams to reflect added fixture(s), as required. " Provide WPGFCI receptacle outlets, on the roof, spaced so that no piece of roof mounted equipment is more than 25' from a receptacle outlet. " Provide electrical disconnect(s) at water heater(s). " Provide an additional exit light, on the corridor #204 side of the corridor door, near rooms marked "checkout" and "billing". " Provide emergency egress illumination for the public area restrooms. " Provide emergency egress illumination for the waiting room #200. Larry Woodrome, CBO Chief Plans Examiner City of Palm Coast 386-986-3786
FI1 COMPLETE 06/19/2006 07/07/2006
Note: Released By: JPATTEE Held By: JPATTEE Provide design criteria for automatic fire sprinkler system per the FAC 61G15-32 (5)
FI1 COMPLETE 07/24/2006
Note: Released By: JPATTEE
BLD COMPLETE 08/18/2006
Note: Released By: LWOODROME

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
MISCELLANEOUS ¤40.00 07/17/2007
REINSPECTION FEE ¤40.00 07/16/2007
TRANSPORTATION IMPACT FEE ¤118,949.43 08/22/2006
PERMIT FEE ¤6,187.50 08/22/2006
PLAN CHECK FEE ¤1,293.75 08/22/2006
PLUMBING FEE ¤705.00 08/22/2006
RADON FEE ¤66.54 08/22/2006
ADMIN FEE ¤20.00 08/22/2006
BUILDING CODE ADMIN FUND ¤66.54 08/22/2006
ELECTRIC FEE ¤705.00 08/22/2006
FIRE COMM IMPACT FEE 4-1-05 ¤6,615.41 08/22/2006
FIRE PLANS REVIEW ¤133.08 08/22/2006
MECHANICAL FEE ¤705.00 08/22/2006
Fees Total Due: ¤0.00 Total Paid: ¤135,527.25