I want to search for...
Permit #2006060814
Permit Details
Status: COED
| Parcel Id: 07-11-31-7029-00510-0040 |
| CONDITIONED SPACE: 2565 sqft |
| GARAGE: 460 sqft |
| OPENED PORCH (WITH ROOF) : 24 sqft |
| OPENED PORCH (WITH ROOF) : 149 sqft |
| OPENED PORCH (WITH ROOF) : 60 sqft |
| Total Square Footage: 3258 sqft |
| Block: 00510 |
| Subdivision: - |
| Job Phone: (386)445-9009 |
| Location Address: 151 RYBERRY DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/30/2006 |
| NOC: RECORDED |
| Applicant name: BRIAN ANDREW GAZZOLI |
| Owner: SEAGATE HOMES, INC A FLORIDA CORP |
|
Address 185 CYPRESS POINT PKWY PALM COAST, FL 32164 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤279,458.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SEAGATE HOMES INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
185 CYPRESS POINT PARKWAY Palm Coast, FL 32137 |
SUITE 7 Palm Coast, FL 32137 |
CRC057202 (Exp: 08/31/2010) | 386-246-6125 | 386-246-6124 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
MILLARD K KELLER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
313 S. VOLUSIA AVENUE DELAND, FL 32724 |
CCC1325778 (Exp: 08/31/2010) | (386) 774-9961 | (386)774-2388 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 03/20/2007 | FINAL APPROVED | JHINDMAN |
| Note: | |||
| FINAL COMPLETE BUILDING INSPECTION | 03/19/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: MASTER BEDROOM PORCH SWITCH DOES NOT HAVE ARC FAULT PROTECTION | |||
| STORMWATER FINAL INSPECTION | 03/16/2007 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION 0 road damage | |||
| STORMWATER FINAL INSPECTION | 03/08/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: ON THE LEFT BACK REAR , YOU NEED TO MAKE A 4 TO 1 SLOPE , THEN ADD SOD . ALLSO YOU NEED TO SOD SWALE RIGHT 4' X 4' SORRY NO SEED IN CENTER OF SWALE . 68 sq ft road damage | |||
| UTILITY COMPANY FINAL | 03/07/2007 | APPROVED | MBACON |
| RESIDENTIAL EARLY POWER | 03/06/2007 | APPROVED | LHITES |
| Note: request per Connie | |||
| DRIVEWAY | 02/15/2007 | APPROVED | GLALIMA |
| LINTEL | 12/27/2006 | APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 12/18/2006 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 12/15/2006 | CANCELLED BY APPLICANT | CMINI |
| Note: DENNIS CANCELLED NOT READY. | |||
| INSULATION INSPECTION | 12/01/2006 | APPROVED | ACOOPER |
| ALL ROUGH | 11/29/2006 | APPROVED | ACOOPER |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 11/15/2006 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: Front windows and arches missing. Extend conduit on island 6", Frame chimney flue, metal chimney flue missing. | |||
| ALL ROUGH | 11/01/2006 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: cancelled by dennis 10 am | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/23/2006 | APPROVED - AS NOTED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/18/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: VALLEY STRAPS NOT NAILED. MANY STRAPS NOT NAILED.NEED TO BLOCK FLAT TOP HIP TRUSSES THAT ARE MORE THAN 24". LINTEL CORNER OUTSIDE OF MASTER BATH NOT SOLID REBAR EXPOSED. NOT READY. | |||
| LINTEL | 10/06/2006 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTIONepoxy is not properly mixed. it is not hardening. | |||
| LINTEL | 10/03/2006 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: Several drilled dowels about one inch deep, redrill and properly epoxy after blowing out dust, missing steel over rear header. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 09/29/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 08/08/2006 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 08/04/2006 | APPROVED | JLEVRAULT |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 08/11/2006 | 08/15/2006 |
| Note: Released By: CCOTE Approved for Release. Revision: Fireplace. | |||
| BLD | COMPLETE | 07/28/2006 | 08/01/2006 |
| Note: Released By: LWOODROME Revision: Internal base plan and truss connectors | |||
| BLD | COMPLETE | 06/27/2006 | 06/29/2006 |
| Note: Released By: LWOODROME Approved for release as noted. Checked by JJ | |||
| SW1 | COMPLETE | 06/22/2006 | 06/26/2006 |
| Note: Released By: WKINELL | |||
| ZON | COMPLETE | 06/22/2006 | 06/27/2006 |
| Note: Released By: ECOYNE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 03/20/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 03/20/2007 |
| REINSPECTION FEE | ¤40.00 | 03/20/2007 |
| REINSPECTION FEE | ¤40.00 | 03/20/2007 |
| REINSPECTION FEE | ¤40.00 | 03/20/2007 |
| REINSPECTION FEE | ¤40.00 | 03/20/2007 |
| REINSPECTION FEE | ¤40.00 | 03/20/2007 |
| REVISION | ¤40.00 | 03/20/2007 |
| REVISION | ¤40.00 | 03/20/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 03/20/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 06/30/2006 |
| ADMIN FEE | ¤20.00 | 06/30/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 06/30/2006 |
| BUILDING CODE ADMIN FUND | ¤16.29 | 06/30/2006 |
| ELECTRIC FEE | ¤198.00 | 06/30/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 06/30/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/30/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 06/30/2006 |
| MECHANICAL FEE | ¤198.00 | 06/30/2006 |
| PERMIT FEE | ¤1,092.00 | 06/30/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 06/30/2006 |
| PLAN CHECK FEE | ¤112.00 | 06/30/2006 |
| PLUMBING FEE | ¤198.00 | 06/30/2006 |
| RADON FEE | ¤16.29 | 06/30/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,637.48 |