I want to search for...
Permit #2006060976
Permit Details
Status: COED
| Parcel Id: 29-10-31-5540-01010-0450 |
| CONDITIONED SPACE: 4117 sqft |
| GARAGE: 741 sqft |
| OPENED PORCH (WITH ROOF) : 643 sqft |
| OPENED PORCH (WITH ROOF) : 105 sqft |
| Total Square Footage: 5606 sqft |
| Block: 1010 |
| Subdivision: 1005 - SANCTUARY |
| Job Phone: (386) 445-4747 |
| Location Address: 84 OLD OAK DR S |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/21/2006 |
| NOC: RECORDED |
| Applicant name: WILLIAM VALENTINE GROFF |
| Owner: ROBERT DALE LONG,SR |
|
Address PONTE VEDRA PALM COAST, FL 32137 |
|
Address 5 COLLIER COURT PALM COAST, FL 32137 |
| Lot: 0450 |
| Contracted Stated Job Value: ¤525,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
COUNTRY CLUB HOMES OF FLORIDA, INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
4440 N. Oceanshore Blvd Palm Coast, FL 32137 |
SUITE 101 Palm Coast, FL 32137 |
CRC043737 (Exp: 08/31/2012) | (386) 445-4747 | (386)445-5955 |
Sub Contractors
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. US # 1 Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2012) | (386) 672-8494 | (386)673-7856 |
GARY S WELBORN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1709 North Nova Road Holly Hill, FL 32117 |
CFC037140 (Exp: 08/31/2018) | (386) 257-1172 | (386)252-5979 |
WAYNE STEED
| Status | Location Address | State License Number | Phone |
| CANCEL |
318 N. PINE AVENUE IVERNESS, FL 34450 |
CCC058299 (Exp: 08/31/2010) | (352)637-2422 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 11/01/2007 | FINAL APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 10/25/2007 | CANCELLED BY APPLICANT | JGIBSON |
| Note: THIS IS A REINSPECTION CANCELED BY CONTRACTOR. | |||
| FINAL COMPLETE BUILDING INSPECTION | 10/23/2007 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: MISSING FIRE RATING ON GARAGE ATTIC ACCESS, NEED TO LABLE AND IDENTIFY A/C AND A/H UNITS ,NEED REVISION ON DELETION OF SUMMER KIT. SINK AND FIRE PLACE, CAP OF AND BLANK ISLAND ELECTRIC, MISSING EXSPANTION DEVICE ON CLOSED WATER SYSTEM, SEAL ALL WATER CLOSETS AT FLOOR, STRAP AND SECURE GAS LINE TO DELETED FIRE PLACE. MARK 931-2912 | |||
| UTILITY COMPANY FINAL | 09/25/2007 | APPROVED | TSCHWEERS |
| STORMWATER FINAL INSPECTION | 09/17/2007 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 09/13/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: THIS IS A REINSPECTION / SOD REAR RIGHT DRAINAGE DITCH BANK . AT AIR UNIT MAKE BANK A MAINTAINABLE SLOP . ALL SO'' YOU HAVE THE GUTTER IN REAR AT CORNER LEFT 6'' BELOW GRADE WITH NO PIPE . SORRY IT MUST DRAIN . | |||
| STORMWATER FINAL INSPECTION | 08/28/2007 | CANCELLED BY APPLICANT | DRANDALL |
| RESIDENTIAL EARLY POWER | 06/05/2007 | APPROVED | LHITES |
| Note: CALLED FPL 6/5 | |||
| INSULATION INSPECTION | 03/12/2007 | APPROVED | RMARVEL |
| INSULATION INSPECTION | 03/08/2007 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: MASTER TUB NOT SET , FRONT DOOR NOT IN MISSING FIRE BLOCKING, ALSO NEED TO FOAM UP AROUND PLUMBING STACKS IN MASTER AND POOL BATH | |||
| INSULATION INSPECTION | 03/07/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: SEAL ALL TOP PLATE PENETRATIONS AND CHASES | |||
| ALL ROUGH | 03/02/2007 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| GAS ROUGH | 03/02/2007 | APPROVED | JMCGOWEN |
| ALL ROUGH | 03/01/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NEED TO ADD NAIL PLATES AT GARAGE WALL. FIRESTOP MISSING AT LEFT OF FRONT ENTRY CHASE WALL. NEED TO CALL IN FOR GAS ROUGH. | |||
| LATH /BRICK FLASHING | 02/02/2007 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 02/01/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: THIS IS A REINSPECTION NOT READY-FINISH ENTRY | |||
| TEMPORARY POLE | 02/01/2007 | APPROVED | LHITES |
| Note: LARRY CALLED FOR ME TO SQUEDULE INSP FOR TODAY MD | |||
| LATH /BRICK FLASHING | 01/18/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: cannot do inspection until cell at front of the house is filled. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/19/2006 | APPROVED | JGIBSON |
| LINTEL | 10/31/2006 | APPROVED | LHITES |
| FLOOD ZONE 'A' ELEVATION CERTIFICATE APPROVAL | 10/30/2006 | APPROVED | CBENTLEY |
| MONOLITHIC SLAB INSPECTION/SLAB | 09/25/2006 | APPROVED | RMARVEL |
| FIRST ROUGH PLUMBING INSPECTION | 09/15/2006 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/24/2007 | 10/25/2007 |
| Note: Released By: FREODICA Rev.- Deleted fireplace, outside kitchen sink and outside cooker. | |||
| BLD | COMPLETE | 01/16/2007 | 01/18/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Truss Repairs A1, A2, A9. | |||
| BLD | COMPLETE | 08/11/2006 | 08/15/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| PLFM | COMPLETE | 08/02/2006 | 08/18/2006 |
| Note: Released By: KIANNOTTI At the direction of Constance Bentley | |||
| SW1 | COMPLETE | 06/28/2006 | 08/14/2006 |
| Note: Released By: LAPTEKAR added Flood Zone A approval in lieu of foundation survey after monolithic slab | |||
| ZON | COMPLETE | 06/28/2006 | 06/28/2006 |
| Note: Released By: HHERKERT flood zone certificate is required by flood plain manager, Constance Bentley | |||
| URB | HOLD | 06/28/2006 | 06/30/2006 |
| Note: Held By: CBENNETT CB 6/30/06 Upon site inspection no barricades installed. Install barricades properly and call for reinspecion 986.3722. | |||
| URB | HOLD | 07/18/2006 | |
| Note: Held By: CBENNETT 7/18/06 CB BARRICADES ARE INSTALL AND LOOK GOOD. THERE IS A GOPHER HOLE ON SITE WHICH IS IN THE BUILDING FOOT PRINT. BUILDER NEEDS TO GET PERMIT FROM THE BUREAU OF WILDLIFE DIVERSITY CONSERVATION 352.732.1225. WILLIAM WILL CALL ME WHEN THEY HAVE THE PERMIT. 7/25/06 CB WILLIAM CAME IN AND WE CALLED THE WILDLIFE CONSERVATION DEPT AND SPOKE WITH SARA. CURRENTLY THEY HAVE NOT APPLIED FOR THE RELOCATION PERMIT. ALSO, RAY TYNER STOPPED BY THE OFFICE TO TALK ABOUT THE TORTOISE. HE SAID IT WAS OKAY TO KEEP THE PERMIT ON HOLD UNTIL THE BUILDER HAS RECEIVED HIS PERMIT. | |||
| URB | COMPLETE | 08/02/2006 | |
| Note: Released By: CBENNETT CB 8/2/06 Spoke with William and home owner has applied for the necessary gopher relocation permit. I am releasing the permit and have requested a copy of the permit. | |||
| BLD | HOLD | 08/02/2006 | |
| Note: Held By: JJOSEPH 1 -Provide masonry details. 2 -Omit details that do no apply to this specific project. 3- Provide project specific truss connector schedule; identify connectors to be used for each trus connection point |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 11/01/2007 |
| REINSPECTION FEE | ¤40.00 | 11/01/2007 |
| REINSPECTION FEE | ¤40.00 | 11/01/2007 |
| REINSPECTION FEE | ¤40.00 | 11/01/2007 |
| REINSPECTION FEE | ¤40.00 | 11/01/2007 |
| REINSPECTION FEE | ¤40.00 | 11/01/2007 |
| REINSPECTION FEE | ¤40.00 | 11/01/2007 |
| REVISION | ¤40.00 | 11/01/2007 |
| REVISION | ¤40.00 | 11/01/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 11/01/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 08/21/2006 |
| ADMIN FEE | ¤20.00 | 08/21/2006 |
| BUILDING CODE ADMIN FUND | ¤28.03 | 08/21/2006 |
| ELECTRIC FEE | ¤345.00 | 08/21/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 08/21/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/21/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 08/21/2006 |
| MECHANICAL FEE | ¤345.00 | 08/21/2006 |
| PERMIT FEE | ¤2,047.50 | 08/21/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 08/21/2006 |
| PLAN CHECK FEE | ¤210.00 | 08/21/2006 |
| PLUMBING FEE | ¤345.00 | 08/21/2006 |
| RADON FEE | ¤28.03 | 08/21/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤12,030.46 |