Permit #2006060977
Permit Details
Status: COED
| CONDITIONED SPACE: 3434 sqft |
| GARAGE: 797 sqft |
| OPENED PORCH (WITH ROOF) : 212 sqft |
| OPENED PORCH (WITH ROOF) : 131 sqft |
| OPENED PORCH (WITH ROOF) : 40 sqft |
| Total Square Footage: 4614 sqft |
| Subdivision: 2081 - Creekside Village at Grand Haven |
| Job Phone: (386) 445-4747 |
| Location Address: 30 CREEKSIDE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/03/2006 |
| NOC: RECORDED |
| Applicant name: WILLIAM VALENTINE GROFF |
| Owner: BEVERIDGE, DONALD W & BETTY J |
|
Address 2130 DEER RUN LEXAHATCHEE, FL 33470 |
| Lot: 44 |
| Contracted Stated Job Value: ¤475,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
COUNTRY CLUB HOMES OF FLORIDA, INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
4440 N. Oceanshore Blvd Palm Coast, FL 32137 |
SUITE 101 Palm Coast, FL 32137 |
CRC043737 (Exp: 08/31/2012) | (386) 445-4747 | (386)445-5955 |
Sub Contractors
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. US # 1 Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2012) | (386) 672-8494 | (386)673-7856 |
GARY S WELBORN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1709 North Nova Road Holly Hill, FL 32117 |
CFC037140 (Exp: 08/31/2018) | (386) 257-1172 | (386)252-5979 |
MELINDA E RYAN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
588 MONROE RD SANFORD, FL 32771 |
CCC057634 (Exp: 08/31/2010) | 407-330-9303 | 407-330-5959 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 04/23/2007 | FINAL APPROVED | JMCGOWEN |
| FINAL COMPLETE BUILDING INSPECTION | 04/20/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: Contractor called to schedule a final inspection for 4/20/07 NEED TO IDENTIFY BREAKERS TO EACH A/C UNIT.....NEED TO HAVE SMOKES 3` AWAY FROM FAN BLADES....SWITCH COVERS NEED TO BE INSTALLED.,.. | |||
| UTILITY COMPANY FINAL | 04/18/2007 | APPROVED | TSCHWEERS |
| STORMWATER FINAL INSPECTION | 04/17/2007 | APPROVED | DRANDALL |
| Note: already passed 4/16 | |||
| STORMWATER FINAL INSPECTION | 04/16/2007 | APPROVED | DRANDALL |
| STORMWATER FINAL INSPECTION | 04/13/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: seed & straw exposed earth on left side adj. property.....remove all trash from left, rear, & right adj. property [marked with paint].....repair chips in curb at driveway [marked with paint].....clean street | |||
| RESIDENTIAL EARLY POWER | 03/30/2007 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| RESIDENTIAL EARLY POWER | 03/29/2007 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: not ready. hook up vaccuum adapters. | |||
| INSULATION INSPECTION | 11/27/2006 | APPROVED | JGIBSON |
| ALL ROUGH | 11/21/2006 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 11/20/2006 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: cap off pvc at panel. need a receptacle within 6ft of door in dining room. also in the master bedroom hall. missing nail plates for electrical and plumbing. strap NM cable away from range hood duct and recessed cans. over on box fill at garage switch and guest bedroom switch. must maintain 30in. in toilet compartment. strap NM cable in attic every 4.5ft where not supported.A/C duct needs strapped so that dipping or sagging does not occur. | |||
| LATH /BRICK FLASHING | 11/13/2006 | APPROVED | JGIBSON |
| EXTERIOR WALL SHEATHING/SHEAR WALL | 10/26/2006 | APPROVED | JGIBSON |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/26/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 10/13/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Structual page not matching plans on foundation, and floor plan , not ready OK to shingle Cells OK. | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 10/13/2006 | APPROVED | JGIBSON |
| LINTEL | 09/21/2006 | APPROVED | LHITES |
| TEMPORARY POLE | 09/21/2006 | APPROVED | LHITES |
| Note: called susan at fpl | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 09/19/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 09/07/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 09/06/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Garage footer, and entry footer not to plan. | |||
| FIRST ROUGH PLUMBING INSPECTION | 08/25/2006 | APPROVED | KSAMPICO |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/23/2006 | 10/23/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Revised floor plan. Removed post notes and referred to structural drawings for post information. | |||
| BLD | REJECT | 10/18/2006 | 10/20/2006 |
| Note: Rejected By: CCOTE Structural changes require signed and sealed document(s) by an engineer or architect. | |||
| ZON | COMPLETE | 08/28/2006 | 08/28/2006 |
| Note: Released By: ECOYNE Lost site plans | |||
| BLD | COMPLETE | 08/28/2006 | 08/29/2006 |
| Note: Released By: CCOTE Approved for Release. REVISION: Changed foundation plan, framing plan, trusses and wall bearing heights. Revised sheets S0.0, S1.0, S1.1. | |||
| BLD | COMPLETE | 07/27/2006 | 08/03/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. | |||
| BLD | HOLD | 07/12/2006 | 07/14/2006 |
| Note: Held By: CCOTE Revised drawings addressing the following items must be submitted in order to complete the Building Permit Application plan review. CITY OF PALM COAST o 2 COMMERCE BLVD o PALM COAST, FL 32164 PHONE: 386-986-3780 o FAX: 386-986-3781 1. Sheet S1.0: Filled Cells a. Wall area between Pool Bath & Morning Room only shows 1 filled cell and Sheet S1.1 note 7 indicates there to be 3 filled cells here. Revise note or plan. b. Wall corner junction between Lanai, Great Room and Master Bedroom only shows 1 filled cell and Sheet S1.1 note 7 indicates there to be 3 filled cells here. Revise note or plan. 2. Sheet S1.0: Footing a. Wall at stair well and kitchen denoted as a bearing wall references detail 3/S1.1. The plan dimensions the footing width to be 16" while the detail states that a 2-story wall shall be 20". Revise plan or detail. 3. Sheet S1.1: CMU Reinforcing Note a. Note references a sheet S-2 however this sheet could not be found. Revise note or provide sheet. b. Note states reinforcing at 48" O.C. however the foundation plan shows spacing greater than this. Revise note or foundation plan. 4. Sheet 1.2: Threaded Rod a. The 2nd floor plan does not show all of the threaded rods in the exterior wall. The construction specifications state that the rod spacing to be 6'-8" maximum spacing. Add threaded wall designation per symbol legend. 5. Sheet S2.0: Construction Specifications a. The Bearing wall notes state "sill plate anchors per general notes". Provide information as to how sills to be secured at both conditions; wall below and lvl beam below. b. Shearwall anchoring system notes state that the rod to be attached to the foundation and the uppermost plate. This cannot be done on 3 walls because the walls sit on beams and there is no wall below. Revise note to state alternate condition or provide detail. If alternate 7/S2.0 is to be used then this should be indicated on the plans. 6. Sheet S2.2: Uplift Connector Schedule a. Schedule submitted is a generic schedule and is not acceptable. Provide a project specific truss connector schedule identify each truss and specific connector to be used at each connection point. b. Note states to provide typ. Connection at trusses as shown below. There is nothing below except for a mitered glass door framing detail. Revise note/provide information as required. 7. Sheet 5a: Attic Access a. No attic access is identified on the 2nd floor level. Revise plan to show access location. 8. Sheet 5a: Structural Information a. The wall sections contain structural information therefore this sheet must be signed and sealed or the structural information must be removed and moved to a structural sheet. b. Section 1/5A foundation dimensions do not the detail 5/S1.1 identified on the foundation plan. Revise this section or update foundation plan and detail. In addition, based on the grading plan the depth required may be more than what is shown. 9. General a. The City requires that all house permits to be project specific therefore all details that do not apply to this particular project shall be removed or crossed out. ------------------------------------------------- Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us ------------------------------------------------- | |||
| URB | HOLD | 07/05/2006 | 07/06/2006 |
| Note: Held By: CBENNETT CB 7/6/06 Several hardwood trees 6" and/or greater are not shown on plan, provide a correct survey. Also, the saved trees are not barricaded. 1. Provide correct survey 2. Barricade saved trees and call for reinspection 986.3722 | |||
| SW1 | COMPLETE | 06/28/2006 | 06/30/2006 |
| Note: Released By: WKINELL | |||
| ZON | COMPLETE | 06/28/2006 | 07/05/2006 |
| Note: Released By: ECOYNE | |||
| URB | COMPLETE | 07/12/2006 | |
| Note: Released By: CBENNETT CB 7/12/06 Good job on barricading trees. "A" 6" Magnolia has poor form consideration should be given to remove. "J" 25" Oak has a large cavity and consideration should be given to the removal of this tree. If the owner does not want to remove keep in mind the tree will come down at some point. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 04/25/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 04/25/2007 |
| REINSPECTION FEE | ¤40.00 | 04/25/2007 |
| REINSPECTION FEE | ¤40.00 | 04/25/2007 |
| REINSPECTION FEE | ¤40.00 | 04/25/2007 |
| REINSPECTION FEE | ¤40.00 | 04/25/2007 |
| REINSPECTION FEE | ¤40.00 | 04/25/2007 |
| REVISION | ¤40.00 | 04/25/2007 |
| REVISION | ¤40.00 | 04/25/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 04/25/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 08/03/2006 |
| ADMIN FEE | ¤20.00 | 08/03/2006 |
| BUILDING CODE ADMIN FUND | ¤23.07 | 08/03/2006 |
| ELECTRIC FEE | ¤315.00 | 08/03/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 08/03/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/03/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 08/03/2006 |
| MECHANICAL FEE | ¤315.00 | 08/03/2006 |
| PERMIT FEE | ¤1,852.50 | 08/03/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 08/03/2006 |
| PLAN CHECK FEE | ¤190.00 | 08/03/2006 |
| PLUMBING FEE | ¤315.00 | 08/03/2006 |
| RADON FEE | ¤23.07 | 08/03/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,715.54 |