I want to search for...
Permit #2006061028
Permit Details
Status: COED
| Parcel Id: 07-11-31-7030-00080-0140 |
| CONDITIONED SPACE: 2154 sqft |
| GARAGE: 442 sqft |
| OPENED PORCH (WITH ROOF) : 162 sqft |
| OPENED PORCH (WITH ROOF) : 62 sqft |
| Total Square Footage: 2820 sqft |
| Block: 00080 |
| Subdivision: - |
| Job Phone: (386)437-5782 |
| Location Address: 30 RAEMOND LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/31/2007 |
| NOC: RECORDED |
| Applicant name: SANDRA LEE FRENCH |
| Owner: GOCKING ODECIR & YARA H&W |
|
Address 47 REED STREET NEW BEDFORD, MA 02740 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SANDEX HOMES
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
27 EGAN DR PALM COAST, FL |
CRC1327302 (Exp: 09/30/2008) | (386)437-5782 | (386)437-5782 |
Sub Contractors
STEVEN JAY SMITH
| Status | Location Address | State License Number | Phone |
| INACTIVE |
104 West Cedar Avenue Orange City, FL 32763 |
EC0001542 (Exp: 08/31/2022) | (386)775-7776 |
MICHAEL DAVID CLARK
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 918 Bunnell, FL 32110 |
CAC044867 (Exp: 09/30/2008) | (386) 437-2001 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
BRUCE EDWARD HAWKESWORTH
| Status | Location Address | State License Number | Phone |
| CANCEL |
671 Dara Circle DELTONA, FL 32735 |
CFC053329 (Exp: 09/30/2008) | (386) 228-2784 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 05/25/2007 | FINAL APPROVED | JMCGOWEN |
| FINAL COMPLETE BUILDING INSPECTION | 05/24/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NEED TO HAVE LIGHT AT FRONT ENTRANCE.....NEED TO HAVE VACUM BREAKER ON LAUNDRY TUB FAUCET.. MASTER CLOSET LIGHTING NEEDS TO BE MIN. OF12" FROM SHELF...NEED TO HAVE A 90 ON CONDISATE LINE... | |||
| STORMWATER FINAL INSPECTION | 05/21/2007 | APPROVED - AS NOTED | DRANDALL |
| Note: THIS IS A REINSPECTION 30 sf road//rechecked inspection | |||
| STORMWATER FINAL INSPECTION | 05/18/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: 30 sf road damage.....need 4 to 1 slope along rear property, come in 4' from property line, slope 4 to 1 to end at property line | |||
| UTILITY COMPANY FINAL | 05/09/2007 | APPROVED | MBACON |
| STORMWATER FINAL INSPECTION | 05/09/2007 | CANCELLED BY APPLICANT | GLALIMA |
| Note: not ready | |||
| DRIVEWAY | 04/25/2007 | APPROVED | GLALIMA |
| PRE DRIVEWAY | 04/23/2007 | CANCELLED BY INSPECTOR | GLALIMA |
| Note: SOME ONE RAN OVER FORMS . | |||
| INSULATION INSPECTION | 04/11/2007 | APPROVED | ACOOPER |
| Note: | |||
| INSULATION INSPECTION | 04/10/2007 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: BLOCK OR FILL AROUND THREADED ROD IN LIVING ROOM WALL. | |||
| LATH /BRICK FLASHING | 04/10/2007 | APPROVED | ACOOPER |
| Note: | |||
| ALL ROUGH | 04/05/2007 | APPROVED | JMCGOWEN |
| Note: | |||
| ALL ROUGH | 04/04/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: BOX FILL AT LAUNDRY HALL WAY IS OVERLOADED.....NEED TO UNBUNDLE WIRES AT MASTER BATH SWITCHES.....NEED TO BLOCK SILL PLATES AT BATH #2 TUB... | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/22/2007 | APPROVED | PGALLMANN |
| Note: | |||
| LINTEL | 03/07/2007 | APPROVED | JHINDMAN |
| Note: | |||
| LINTEL | 02/21/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: PLAN DOES NOT SHOW USING A STEEL LINTEL AT REAR PORCH | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 02/20/2007 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 02/05/2007 | APPROVED | JHINDMAN |
| Note: | |||
| FIRST ROUGH PLUMBING INSPECTION | 02/01/2007 | APPROVED | JHINDMAN |
| Note: |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/07/2007 | 03/08/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Truss layout change and updated connector schedule. | |||
| BLD | COMPLETE | 03/06/2007 | 03/06/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Lintel substitution. | |||
| BLD | REJECT | 02/28/2007 | 03/01/2007 |
| Note: Rejected By: CCOTE The following items must be corrected in order to process the attached revision. 1. The plans do not have any openings identified as L-23. Clarify which opening will receive this lintel substitution. 2. The gravity load stated does not match that listed in the Powers Steel table attached. Review tables and update to match tables or provide calculations for increased load capacity. 3. The reinforcing stated does not match what is required per footnote of Powers Steel table attached. Revise to match that required by Powers Steel or provide calculations for reinforcing specified. 4. Clearly specify Powers Steel type to be used as listed at top of Tables. 5. In addition state that lintel also meets the imposed uplift loads. ------------------------------------------------- Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us ------------------------------------------------- | |||
| BLD | COMPLETE | 06/30/2006 | 07/05/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | COMPLETE | 06/29/2006 | 07/06/2006 |
| Note: Released By: WKINELL Front half of left side appears to be draining up hill to the front. Re-evaluate the proposed elevations and advise the Stormwater Department of any changes. Application released.\\wk | |||
| ZON | COMPLETE | 06/29/2006 | 06/30/2006 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ENGINEERING ROAD DAMAGE | ¤340.00 | 05/25/2007 |
| REINSPECTION FEE | ¤40.00 | 05/25/2007 |
| REINSPECTION FEE | ¤40.00 | 05/25/2007 |
| REINSPECTION FEE | ¤40.00 | 05/25/2007 |
| REINSPECTION FEE | ¤40.00 | 05/25/2007 |
| REVISION | ¤40.00 | 05/25/2007 |
| REVISION | ¤40.00 | 05/25/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 01/31/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/31/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 01/31/2007 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 01/31/2007 |
| MECHANICAL FEE | ¤154.80 | 01/31/2007 |
| PERMIT FEE | ¤811.20 | 01/31/2007 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 01/31/2007 |
| PLAN CHECK FEE | ¤83.20 | 01/31/2007 |
| PLUMBING FEE | ¤154.80 | 01/31/2007 |
| RADON FEE | ¤14.10 | 01/31/2007 |
| ADMIN FEE | ¤20.00 | 01/31/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 01/31/2007 |
| BUILDING CODE ADMIN FUND | ¤14.10 | 01/31/2007 |
| ELECTRIC FEE | ¤154.80 | 01/31/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,378.90 |