I want to search for...
Permit #2006061070
Permit Details
Status: COED
| Parcel Id: 07-11-31-7029-00420-0140 |
| CONDITIONED SPACE: 2453 sqft |
| GARAGE: 492 sqft |
| OPENED PORCH (WITH ROOF) : 117 sqft |
| OPENED PORCH (WITH ROOF) : 61 sqft |
| Total Square Footage: 3123 sqft |
| Block: 00420 |
| Subdivision: - |
| Job Phone: (386)445-9009 |
| Location Address: 27 RYBARK LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/06/2006 |
| NOC: RECORDED |
| Applicant name: BRIAN ANDREW GAZZOLI |
| Owner: SEAGATE HOMES |
|
Address 185 CYPRESS POINT PKWY PALM COAST, FL 32164 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤274,460.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SEAGATE HOMES INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
185 CYPRESS POINT PARKWAY Palm Coast, FL 32137 |
SUITE 7 Palm Coast, FL 32137 |
CRC057202 (Exp: 08/31/2010) | 386-246-6125 | 386-246-6124 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
MICHAEL G MORELLO JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32137 |
CAC014293 (Exp: 08/31/2014) | (386)447-3950 | (386)446-4614 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
MILLARD K KELLER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
313 S. VOLUSIA AVENUE DELAND, FL 32724 |
CCC1325778 (Exp: 08/31/2010) | (386) 774-9961 | (386)774-2388 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 02/19/2007 | FINAL APPROVED | JHINDMAN |
| Note: | |||
| STORMWATER FINAL INSPECTION | 02/15/2007 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION MADE A CALL TO BOB SMITH ABOUT DRAINAGE , I TOLD HIM TO TAKE A LOOK A THE DRAINAGE. IT IS NOT TO SURVEY AND HOLDING WATER JUST OUT SIDE , FRONT DOOR AND RUNNING OFF THE RIGHT REAR AND CENTER , BUILDER WILL BE RESPONSIBLE FOR ALL DRAINAGE TO HOME OWNER . 0 road damage | |||
| STORMWATER FINAL INSPECTION | 02/09/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: SURVEY AND GRADE OFF , WATER PONDING IN REAR CENTER ALLSO SURVEY SHOWS WATER COMMING TO FRONT . WOULD LIKE TO HAVE A SITE MEET AT NO COST . CALL GARY LALIMA 931-0208 | |||
| UTILITY COMPANY FINAL | 02/07/2007 | APPROVED | TREESE |
| DRIVEWAY | 01/26/2007 | APPROVED - AS NOTED | LAPTEKAR |
| Note: must have silt fence up | |||
| RESIDENTIAL EARLY POWER | 01/19/2007 | APPROVED | JHINDMAN |
| Note: PER CONNIE | |||
| LATH /BRICK FLASHING | 12/28/2006 | APPROVED | JHINDMAN |
| INSULATION INSPECTION | 12/19/2006 | APPROVED | JHINDMAN |
| ALL ROUGH | 12/12/2006 | APPROVED | JHINDMAN |
| Note: | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/04/2006 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/01/2006 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: Block base of all OSB laid on end on the roof, flat truss span exceeds 24" and must be reinforced. | |||
| LINTEL | 11/07/2006 | APPROVED | ACOOPER |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 11/06/2006 | APPROVED | GLALIMA |
| MONOLITHIC SLAB INSPECTION/SLAB | 10/24/2006 | APPROVED | JHINDMAN |
| Note: | |||
| FIRST ROUGH PLUMBING INSPECTION | 10/18/2006 | APPROVED | JHINDMAN |
| Note: |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/05/2006 | 07/05/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | COMPLETE | 06/30/2006 | 07/06/2006 |
| Note: Released By: LAPTEKAR checked with JM regarding ditch | |||
| ZON | COMPLETE | 06/30/2006 | 07/05/2006 |
| Note: Released By: HHERKERT |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 02/20/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 02/20/2007 |
| REINSPECTION FEE | ¤40.00 | 02/20/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 02/20/2007 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 07/06/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 07/06/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/06/2006 |
| ADMIN FEE | ¤20.00 | 07/06/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 07/06/2006 |
| BUILDING CODE ADMIN FUND | ¤15.62 | 07/06/2006 |
| ELECTRIC FEE | ¤195.00 | 07/06/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 07/06/2006 |
| MECHANICAL FEE | ¤195.00 | 07/06/2006 |
| PERMIT FEE | ¤1,072.50 | 07/06/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 07/06/2006 |
| PLAN CHECK FEE | ¤110.00 | 07/06/2006 |
| PLUMBING FEE | ¤195.00 | 07/06/2006 |
| RADON FEE | ¤15.62 | 07/06/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,365.64 |