I want to search for...

Permit #2006070492

Permit Details

Status: COED

Parcel Id: 07-11-31-7007-00560-0110
CONDITIONED SPACE: 1809 sqft
GARAGE: 524 sqft
OPENED PORCH (WITH ROOF) : 297 sqft
OPENED PORCH (WITH ROOF) : 64 sqft
Total Square Footage: 2694 sqft
Block: 00560
Subdivision: -
Job Phone: (386) 437-2800
Location Address: 98 FULTON PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/22/2006
NOC: RECORDED
Applicant name: JOHN E RAWLINS
Owner: PAUL MCLAUGHLIN

Address

8 CEDARVIEW COURT

PALM COAST, FL 32137

Lot: 0110
Contracted Stated Job Value: ¤155,000.00
Job Description: SINGLE FAMILY
Type: CN

Contractor

JOHN RAWLINS CONST.INC DBA ELITE HOMES OF FLAGLER
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 1583

Bunnell, FL 32110

CRC021225 (Exp: 08/31/2026) (386) 437-2800 (386)437-2314

Sub Contractors

JOPSEH GARDNER
Status Location Address State License Number Phone
CANCEL

PO Box 762

, FL 32110

EC13003038 (Exp: 09/30/2008) (386) 672-0640
THOMAS ALAN MOSE
Status Location Address State License Number Phone Fax
INACTIVE

PO BOX 1894

HOLLY HILL, FL 32117

CAC048082 (Exp: 08/31/2026) 386-255-4545 (386)252-4979
ALFERD MITCHUM FUTCH
Status Location Address State License Number Phone Fax
CANCEL

1218 San Jose Blvd

Holly Hill, FL 32117

CFC044175 (Exp: 08/31/2012) (386) 672-3576 (386)672-0107
EUGENIA MAY MILHOLEN
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 2088

Bunnell, FL 32110

CCC048174 (Exp: 08/31/2010) (386) 437-6457 (386)437-6457

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 04/10/2007 FINAL APPROVED JMCGOWEN
Note:
STORMWATER FINAL INSPECTION 04/09/2007 APPROVED DRANDALL
UTILITY COMPANY FINAL 04/09/2007 APPROVED TSCHWEERS
UTILITY COMPANY FINAL 04/05/2007 APPROVED TSCHWEERS
DRIVEWAY 03/02/2007 APPROVED DRANDALL
INSULATION INSPECTION 01/24/2007 APPROVED JGIBSON
ALL ROUGH 01/18/2007 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
ALL ROUGH 01/16/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: THIS IS A REINSPECTION recheck prior list. plus cap off added conduit at the panel. NOT READY.
ALL ROUGH 01/12/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: THIS IS A REINSPECTION DO NOT STAPLE NM CABLE ON EDGE. RECHECK BOXES FOR BOX FILL. MISSING NUMEROUS NAIL PLATES. MISSING FIRE STOP. STRAP NM CABLE EVERY 4.5FT. DON OT MIX 12 AND 14AWG WIRE ON THE SAME CIRCUIT. EX FAN DUCT MISSING. STRAP A/C DUCT SO THAT NO SAGS OCCUR. UNUSED OPENINGS NEED TO BE CLOSED. WHITE CONDUCTORS USED AS HOT CONDUCTORS NEED TO BE MARKED AS SUCH. NOT READY.
ALL ROUGH 01/10/2007 Disapproved -FEE REQUIRED JGIBSON
Note: Missing ground screw in pancake in back bedroom,add out-let @ right side as you enter house,wires not straped @ panel,seal or cap off extra conduit @ panel.
LATH /BRICK FLASHING 12/22/2006 APPROVED RMARVEL
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/11/2006 APPROVED - AS NOTED JGIBSON
Note: Check for revision @ aa-rough for window in master bedroom
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/07/2006 Disapproved -FEE REQUIRED CMINI
Note: THREADED RODS AND ANCHOR BOLT NUTS NOT TIGHTENED. MISSING 2X4 STUD AT GARAGE DOOR PER PLAN. NEED TAPCONS IN ARCH WINDOW FRAMING PER PLAN. NEED REVISION FOR DELETED WINDOW IN MASTER BED RM. MISSING NAILS IN BUCKETS IN GIRDER HG04 IN MASTER BATH.
LINTEL 10/20/2006 APPROVED JGIBSON
FOUNDATION SURVEY APPROVED BY STORMWATER 10/19/2006 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 09/29/2006 APPROVED LHITES
FIRST ROUGH PLUMBING INSPECTION 09/26/2006 APPROVED LHITES

Review History

Department Status Date In Date Out
BLD CANCEL 01/04/2007
BLD COMPLETE 09/07/2006 09/08/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
BLD HOLD 08/25/2006 08/25/2006
Note: Held By: JJOSEPH The following items must be submitted in order to complete the Building Permit Application plan review. 1. The Residential System Sizing Calculation sheet was performed by an outdated version of the EnergyGauge software. Any version lower than 4.0 will not be accepted for either code compliance or system sizing. This software is definitely outdated and should be replaced with version 4.21. The ACCA Manual J is 7 in version 3.3 and WILL NOT be accepted any longer. Version 4.0 of the software has ACCA Manual J 8 and should be accepted as it is certified by ACCA as referenced in the current Florida Building Code. In addition, the energy compliance form is an outdated copy (600A-2001), please submit a current version 600A-2004.
PLFM COMPLETE 07/27/2006 08/08/2006
Note: Released By: CBENTLEY Held By: CBENTLEY Sent email to Bill Butler to inspect the property for floodway.
ZON COMPLETE 07/27/2006 07/27/2006
Note: Released By: ECOYNE
ZON HOLD 07/21/2006 07/25/2006
Note: Held By: HHERKERT Hold for ARC meeting 7-28-06
SW1 HOLD 07/21/2006 07/25/2006
Note: Held By: LAPTEKAR The proposed FFE is low in relation to the proposed existing grade elevations and the neighboring FFE's.
SW1 COMPLETE 07/26/2006
Note: Released By: LAPTEKAR Received new topo survey with adjusted FFE and lot grading
PLFM COMPLETE 08/22/2006
Note: Released By: CBENTLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/11/2007
REINSPECTION FEE ¤40.00 04/11/2007
REINSPECTION FEE ¤40.00 04/11/2007
REINSPECTION FEE ¤40.00 04/11/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 09/22/2006
STORM WATER PERMIT FEES ¤80.00 09/22/2006
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 09/22/2006
ADMIN FEE ¤40.00 09/22/2006
ARC HOUSE REVIEW ¤125.00 09/22/2006
BUILDING CODE ADMIN FUND ¤13.47 09/22/2006
ELECTRIC FEE ¤283.20 09/22/2006
FIRE IMPACT FEE 4-1-06 ¤179.37 09/22/2006
MECHANICAL FEE ¤283.20 09/22/2006
PERMIT FEE ¤1,450.80 09/22/2006
PARKS IMPACT FEE 4/1/06 ¤1,159.02 09/22/2006
PLAN CHECK FEE ¤148.80 09/22/2006
PLUMBING FEE ¤283.20 09/22/2006
RADON FEE ¤13.47 09/22/2006
Fees Total Due: ¤0.00 Total Paid: ¤11,068.04