I want to search for...
Permit #2006070492
Permit Details
Status: COED
| Parcel Id: 07-11-31-7007-00560-0110 |
| CONDITIONED SPACE: 1809 sqft |
| GARAGE: 524 sqft |
| OPENED PORCH (WITH ROOF) : 297 sqft |
| OPENED PORCH (WITH ROOF) : 64 sqft |
| Total Square Footage: 2694 sqft |
| Block: 00560 |
| Subdivision: - |
| Job Phone: (386) 437-2800 |
| Location Address: 98 FULTON PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/22/2006 |
| NOC: RECORDED |
| Applicant name: JOHN E RAWLINS |
| Owner: PAUL MCLAUGHLIN |
|
Address 8 CEDARVIEW COURT PALM COAST, FL 32137 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤155,000.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
JOHN RAWLINS CONST.INC DBA ELITE HOMES OF FLAGLER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 1583 Bunnell, FL 32110 |
CRC021225 (Exp: 08/31/2026) | (386) 437-2800 | (386)437-2314 |
Sub Contractors
JOPSEH GARDNER
| Status | Location Address | State License Number | Phone |
| CANCEL |
PO Box 762 , FL 32110 |
EC13003038 (Exp: 09/30/2008) | (386) 672-0640 |
THOMAS ALAN MOSE
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 1894 HOLLY HILL, FL 32117 |
CAC048082 (Exp: 08/31/2026) | 386-255-4545 | (386)252-4979 |
ALFERD MITCHUM FUTCH
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1218 San Jose Blvd Holly Hill, FL 32117 |
CFC044175 (Exp: 08/31/2012) | (386) 672-3576 | (386)672-0107 |
EUGENIA MAY MILHOLEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P. O. Box 2088 Bunnell, FL 32110 |
CCC048174 (Exp: 08/31/2010) | (386) 437-6457 | (386)437-6457 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 04/10/2007 | FINAL APPROVED | JMCGOWEN |
| Note: | |||
| STORMWATER FINAL INSPECTION | 04/09/2007 | APPROVED | DRANDALL |
| UTILITY COMPANY FINAL | 04/09/2007 | APPROVED | TSCHWEERS |
| UTILITY COMPANY FINAL | 04/05/2007 | APPROVED | TSCHWEERS |
| DRIVEWAY | 03/02/2007 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 01/24/2007 | APPROVED | JGIBSON |
| ALL ROUGH | 01/18/2007 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 01/16/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: THIS IS A REINSPECTION recheck prior list. plus cap off added conduit at the panel. NOT READY. | |||
| ALL ROUGH | 01/12/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: THIS IS A REINSPECTION DO NOT STAPLE NM CABLE ON EDGE. RECHECK BOXES FOR BOX FILL. MISSING NUMEROUS NAIL PLATES. MISSING FIRE STOP. STRAP NM CABLE EVERY 4.5FT. DON OT MIX 12 AND 14AWG WIRE ON THE SAME CIRCUIT. EX FAN DUCT MISSING. STRAP A/C DUCT SO THAT NO SAGS OCCUR. UNUSED OPENINGS NEED TO BE CLOSED. WHITE CONDUCTORS USED AS HOT CONDUCTORS NEED TO BE MARKED AS SUCH. NOT READY. | |||
| ALL ROUGH | 01/10/2007 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Missing ground screw in pancake in back bedroom,add out-let @ right side as you enter house,wires not straped @ panel,seal or cap off extra conduit @ panel. | |||
| LATH /BRICK FLASHING | 12/22/2006 | APPROVED | RMARVEL |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/11/2006 | APPROVED - AS NOTED | JGIBSON |
| Note: Check for revision @ aa-rough for window in master bedroom | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/07/2006 | Disapproved -FEE REQUIRED | CMINI |
| Note: THREADED RODS AND ANCHOR BOLT NUTS NOT TIGHTENED. MISSING 2X4 STUD AT GARAGE DOOR PER PLAN. NEED TAPCONS IN ARCH WINDOW FRAMING PER PLAN. NEED REVISION FOR DELETED WINDOW IN MASTER BED RM. MISSING NAILS IN BUCKETS IN GIRDER HG04 IN MASTER BATH. | |||
| LINTEL | 10/20/2006 | APPROVED | JGIBSON |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 10/19/2006 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 09/29/2006 | APPROVED | LHITES |
| FIRST ROUGH PLUMBING INSPECTION | 09/26/2006 | APPROVED | LHITES |
Review History
| Department | Status | Date In | Date Out |
| BLD | CANCEL | 01/04/2007 | |
| BLD | COMPLETE | 09/07/2006 | 09/08/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| BLD | HOLD | 08/25/2006 | 08/25/2006 |
| Note: Held By: JJOSEPH The following items must be submitted in order to complete the Building Permit Application plan review. 1. The Residential System Sizing Calculation sheet was performed by an outdated version of the EnergyGauge software. Any version lower than 4.0 will not be accepted for either code compliance or system sizing. This software is definitely outdated and should be replaced with version 4.21. The ACCA Manual J is 7 in version 3.3 and WILL NOT be accepted any longer. Version 4.0 of the software has ACCA Manual J 8 and should be accepted as it is certified by ACCA as referenced in the current Florida Building Code. In addition, the energy compliance form is an outdated copy (600A-2001), please submit a current version 600A-2004. | |||
| PLFM | COMPLETE | 07/27/2006 | 08/08/2006 |
| Note: Released By: CBENTLEY Held By: CBENTLEY Sent email to Bill Butler to inspect the property for floodway. | |||
| ZON | COMPLETE | 07/27/2006 | 07/27/2006 |
| Note: Released By: ECOYNE | |||
| ZON | HOLD | 07/21/2006 | 07/25/2006 |
| Note: Held By: HHERKERT Hold for ARC meeting 7-28-06 | |||
| SW1 | HOLD | 07/21/2006 | 07/25/2006 |
| Note: Held By: LAPTEKAR The proposed FFE is low in relation to the proposed existing grade elevations and the neighboring FFE's. | |||
| SW1 | COMPLETE | 07/26/2006 | |
| Note: Released By: LAPTEKAR Received new topo survey with adjusted FFE and lot grading | |||
| PLFM | COMPLETE | 08/22/2006 | |
| Note: Released By: CBENTLEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 04/11/2007 |
| REINSPECTION FEE | ¤40.00 | 04/11/2007 |
| REINSPECTION FEE | ¤40.00 | 04/11/2007 |
| REINSPECTION FEE | ¤40.00 | 04/11/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 09/22/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/22/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 09/22/2006 |
| ADMIN FEE | ¤40.00 | 09/22/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 09/22/2006 |
| BUILDING CODE ADMIN FUND | ¤13.47 | 09/22/2006 |
| ELECTRIC FEE | ¤283.20 | 09/22/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 09/22/2006 |
| MECHANICAL FEE | ¤283.20 | 09/22/2006 |
| PERMIT FEE | ¤1,450.80 | 09/22/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 09/22/2006 |
| PLAN CHECK FEE | ¤148.80 | 09/22/2006 |
| PLUMBING FEE | ¤283.20 | 09/22/2006 |
| RADON FEE | ¤13.47 | 09/22/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,068.04 |