I want to search for...
Permit #2006080275
Permit Details
Status: COED
| Parcel Id: 15-11-31-1950-00000-0310 |
| CONDITIONED SPACE: 3244 sqft |
| GARAGE: 600 sqft |
| OPENED PORCH (WITH ROOF) : 102 sqft |
| OPENED PORCH (WITH ROOF) : 196 sqft |
| OPENED PORCH (WITH ROOF) : 60 sqft |
| OPENED PORCH (WITH ROOF) : 141 sqft |
| Total Square Footage: 4343 sqft |
| Block: 00000 |
| Subdivision: 1062 - FAIRWAYS EDGE |
| Job Phone: (386) 445-4747 |
| Location Address: 22 AUGUSTA TRL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/31/2006 |
| NOC: RECORDED |
| Applicant name: WILLIAM VALENTINE GROFF |
| Owner: MEHL ROBERT R & SUSAN MEHL H&W |
|
Address 117 TURTLE BACK ROAD CALIFTON, NJ 07830 |
| Lot: 0310 |
| Contracted Stated Job Value: ¤410,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
COUNTRY CLUB HOMES OF FLORIDA, INC.
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
4440 N. Oceanshore Blvd Palm Coast, FL 32137 |
SUITE 101 Palm Coast, FL 32137 |
CRC043737 (Exp: 08/31/2012) | (386) 445-4747 | (386)445-5955 |
Sub Contractors
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. US # 1 Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2012) | (386) 672-8494 | (386)673-7856 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
WAYNE STEED
| Status | Location Address | State License Number | Phone |
| CANCEL |
318 N. PINE AVENUE IVERNESS, FL 34450 |
CCC058299 (Exp: 08/31/2010) | (352)637-2422 |
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/14/2007 | FINAL APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/13/2007 | CANCELLED BY APPLICANT | JGIBSON |
| Note: William left a message to schedule this inspection CANCELED BY CONTRACTOR. | |||
| STORMWATER FINAL INSPECTION | 08/09/2007 | APPROVED | DRANDALL |
| UTILITY COMPANY FINAL | 08/09/2007 | APPROVED | TSCHWEERS |
| EXTERIOR WALL SHEATHING/SHEAR WALL | 08/08/2007 | APPROVED | JGIBSON |
| RESIDENTIAL EARLY POWER | 07/05/2007 | APPROVED | LHITES |
| Note: Wayne from Country Club Homes called in a residential early power for 7/5/07 | |||
| INSULATION INSPECTION | 04/24/2007 | APPROVED | JGIBSON |
| Note: | |||
| ALL ROUGH | 04/18/2007 | APPROVED | JMCGOWEN |
| Note: | |||
| ALL ROUGH | 04/17/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NAIL PLATE MISSING ON A/C DRAIN PIPE....NEED TO ADD REC. THAT SPACING IS MORE THAN 12` IN BD.RMS...NEED TO MOCK UP STAIR RISER FOR CORRECT MEASURMENT. | |||
| LATH /BRICK FLASHING | 03/07/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: MUST HAVE REVISION ON ADDING 3RD LVL BEAM ON BACK LANI BEFORE STUCCO CAN BE APPLIED AND INSPECTED | |||
| LATH /BRICK FLASHING | 03/06/2007 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: THIS IS A REINSPECTION MISSING TRANSITION JOINT @ MASORY TO WOOD | |||
| LATH /BRICK FLASHING | 03/02/2007 | CANCELLED BY APPLICANT | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 03/01/2007 | CANCELLED BY APPLICANT | RMARVEL |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/16/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: Need revision letter on bearing wall in master shower. | |||
| RESIDENTIAL EARLY POWER | 01/16/2007 | APPROVED | LHITES |
| Note: this is a tug service it is ok for fpl to set meter | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 12/29/2006 | CANCELLED BY APPLICANT | JGIBSON |
| EXTERIOR WALL SHEATHING/SHEAR WALL | 12/29/2006 | CANCELLED BY APPLICANT | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 12/19/2006 | CANCELLED BY APPLICANT | JGIBSON |
| LINTEL | 11/29/2006 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 11/27/2006 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: Missing vertical steel in rear @ door each side ,inspection holes needed on each side. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 11/22/2006 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 11/09/2006 | APPROVED | CMINI |
| FIRST ROUGH PLUMBING INSPECTION | 11/06/2006 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/13/2007 | 03/14/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: SK-1 Beam layout change and beam modifications. | |||
| ZON | COMPLETE | 08/31/2006 | 08/31/2006 |
| Note: Released By: ECOYNE | |||
| BLD | COMPLETE | 08/28/2006 | 08/28/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| BLD | HOLD | 08/22/2006 | 08/24/2006 |
| Note: Held By: CCOTE The following items must be submitted in order to complete the Building Permit Application plan review. 1. The Residential System Sizing Calculation sheet was performed by an outdated version of the EnergyGauge software. Any version lower than 4.0 will not be accepted for either code compliance or system sizing. This software is definitely outdated and should be replaced with version 4.21. The ACCA Manual J is 7 in version 3.3 and WILL NOT be accepted any longer. Version 4.0 of the software has ACCA Manual J 8 and should be accepted as it is certified by ACCA as referenced in the current Florida Building Code. ------------------------------------------------- Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us ------------------------------------------------- | |||
| ZON | HOLD | 08/18/2006 | 08/18/2006 |
| Note: Held By: ECOYNE Need correct setbacks on plan need landscape (trees) plans Landscaping approved by Carol | |||
| URB | COMPLETE | 08/18/2006 | 08/22/2006 |
| Note: Released By: CBENNETT CB 8/22/06 No existing index trees please provide landscape plan showing your replacement trees. | |||
| SW1 | COMPLETE | 08/10/2006 | 08/14/2006 |
| Note: Released By: LAPTEKAR | |||
| ZON | HOLD | 08/10/2006 | 08/16/2006 |
| Note: Held By: HHERKERT 1. lot area is required on the survey |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 08/15/2007 |
| EARLY POWER INSPECTION | ¤40.00 | 08/15/2007 |
| REINSPECTION FEE | ¤40.00 | 08/15/2007 |
| REINSPECTION FEE | ¤40.00 | 08/15/2007 |
| REINSPECTION FEE | ¤40.00 | 08/15/2007 |
| REVISION | ¤40.00 | 08/15/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 08/31/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/31/2006 |
| TRANS IMPACT FEE 4 - PER UNIT | ¤3,248.51 | 08/31/2006 |
| ADMIN FEE | ¤20.00 | 08/31/2006 |
| BUILDING CODE ADMIN FUND | ¤21.72 | 08/31/2006 |
| ELECTRIC FEE | ¤276.00 | 08/31/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 08/31/2006 |
| MECHANICAL FEE | ¤276.00 | 08/31/2006 |
| PERMIT FEE | ¤1,599.00 | 08/31/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 08/31/2006 |
| PLAN CHECK FEE | ¤164.00 | 08/31/2006 |
| PLUMBING FEE | ¤276.00 | 08/31/2006 |
| RADON FEE | ¤21.72 | 08/31/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,161.34 |