I want to search for...

Permit #2006080511

Permit Details

Status: COED

Parcel Id: 07-11-31-7009-00080-0290
CONDITIONED SPACE: 3224 sqft
GARAGE: 560 sqft
OPENED PORCH (WITH ROOF) : 451 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 4347 sqft
Block: 00080
Subdivision: -
Job Phone: (386)445-9393
Location Address: 36 FARISTON PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/30/2006
NOC: RECORDED
Applicant name: ANTONIO AMARAL JR
Owner: ANTONIO & MARIAL AMARAL

Address

13 UTILITY DRIVE

PALM COAST, FL 32137

Lot: 0290
Contracted Stated Job Value: ¤214,900.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

AMARAL CUSTOM HOMES INC.
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32135

CBC058062 (Exp: 08/31/2020) (386)445-9393 (386)446-0403

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 1963

Bunnell, FL 32110

ER0011613 (Exp: 08/31/2008) (386) 437-0607 (386)437-1847
RONALD E BANKS
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353741

PALM COAST, FL 32164

CAC049308 (Exp: 08/31/2010) (386) 437-4800 (386)445-0030
JAMES JOSEPH SAVNIK JR
Status Location Address State License Number Phone
CANCEL

1120 COUNTY RD 305

BUNNELL, 32110

CPC057381 (Exp: 09/30/2008) (386) 445-1253
ANTONIO JR AMARAL
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32137

CCC058004 (Exp: 08/31/2018) (386)445-9393 (386)446-0403

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 05/11/2007 FINAL APPROVED JGIBSON
FINAL COMPLETE BUILDING INSPECTION 05/04/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: NEED TO INSULATE AND SHEET ROCK UNDER STEPS IN GARAGE.
STORMWATER FINAL INSPECTION 04/19/2007 APPROVED DRANDALL
Note: THIS IS A REINSPECTION sidewalk fixed
STORMWATER FINAL INSPECTION 04/13/2007 Disapproved -FEE REQUIRED DRANDALL
Note: sidewalk around a/c is 3' into 5' utility easement
UTILITY COMPANY FINAL 04/02/2007 APPROVED TSCHWEERS
Note: No permit to sign.
RESIDENTIAL EARLY POWER 03/13/2007 APPROVED RMARVEL
Note: called by DELMIRA
DRIVEWAY 02/13/2007 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
DRIVEWAY 02/08/2007 Disapproved -FEE REQUIRED DRANDALL
Note: survey does not show sidewalk around house, enlarged a/c pad encroches on 5' utility easement, not allowed.....resummit new survey to show all added sidewalks
LATH /BRICK FLASHING 01/11/2007 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 12/18/2006 Disapproved -FEE REQUIRED JGIBSON
Note: A double vapor barrier needed on all wood areas that stuccoo is being applied to.
INSULATION INSPECTION 12/12/2006 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
INSULATION INSPECTION 12/11/2006 Disapproved -FEE REQUIRED RMARVEL
Note: missing fire stop in three locations. kitchenand master bath.
ALL ROUGH 12/05/2006 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
ALL ROUGH 11/30/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: nm cable needs strapped or supported every 4.5ft. over on boxfill in garage switch. derate wires in kitchen island raceway. need 2in of cover over raceway in kitchen. nail plate ent where wood is notched. strap mechanical ducts. move or protect nm cable where it is within 1.25in of furring strips.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 11/15/2006 APPROVED - AS NOTED RMARVEL
Note: strapping detail needed on hinge point of stairwell.
EXTERIOR WALL SHEATHING/SHEAR WALL 11/15/2006 APPROVED RMARVEL
Note: TONY AMARAL ASKED TO HAVE THIS INSPECTION ADDED TO HIS INSPECTION LIST
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 11/08/2006 Disapproved -FEE REQUIRED JMCGOWEN
Note: ok to cover roof. need revision on ballon wall, for hinging point, at stairwall and kitchen.
LINTEL 10/12/2006 APPROVED LHITES
FOUNDATION SURVEY APPROVED BY STORMWATER 10/11/2006 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 09/29/2006 APPROVED LHITES
FIRST ROUGH PLUMBING INSPECTION 09/27/2006 APPROVED LHITES

Review History

Department Status Date In Date Out
BLD COMPLETE 11/21/2006 11/28/2006
Note: Released By: CCOTE Approved for Release. REVISION: Framing strap detail.
BLD COMPLETE 10/09/2006 10/10/2006
Note: Released By: CCOTE Approved for Release. REVISION: Changed rear porch lintels to steel.
BLD COMPLETE 08/28/2006 08/28/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
SW1 COMPLETE 08/18/2006 08/21/2006
Note: Released By: LAPTEKAR
ZON COMPLETE 08/18/2006 08/28/2006
Note: Released By: HHERKERT

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 05/14/2007
REINSPECTION FEE ¤40.00 05/14/2007
REINSPECTION FEE ¤40.00 05/14/2007
REINSPECTION FEE ¤40.00 05/14/2007
REINSPECTION FEE ¤40.00 05/14/2007
REINSPECTION FEE ¤40.00 05/14/2007
REVISION ¤40.00 05/14/2007
REVISION ¤40.00 05/14/2007
STORMWATER REINSPECTION FEE ¤35.00 05/14/2007
STORMWATER REINSPECTION FEE ¤35.00 05/14/2007
TRANS IMPACT FEE 4 - PER UNIT ¤3,248.51 08/30/2006
ADMIN FEE ¤20.00 08/30/2006
ARC HOUSE REVIEW ¤125.00 08/30/2006
BUILDING CODE ADMIN FUND ¤21.74 08/30/2006
ELECTRIC FEE ¤217.20 08/30/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 08/30/2006
STORM WATER PERMIT FEES ¤80.00 08/30/2006
FIRE IMPACT FEE 4-1-06 ¤179.37 08/30/2006
MECHANICAL FEE ¤217.20 08/30/2006
PERMIT FEE ¤1,216.80 08/30/2006
PARKS IMPACT FEE 4/1/06 ¤1,159.02 08/30/2006
PLAN CHECK FEE ¤124.80 08/30/2006
PLUMBING FEE ¤217.20 08/30/2006
RADON FEE ¤21.74 08/30/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,838.58