Permit #2006090629
Permit Details
Status: COED
| COMMERCIAL SQUARE FOOTAGE: 82290 sqft |
| Total Square Footage: 82290 sqft |
| Block: 00000 |
| Subdivision: - |
| Job Phone: (904)260-2900 |
| Location Address: 21 HOSPITAL DR |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 04/16/2007 |
| NOC: RECORDED |
| Applicant name: RONALD H FOSTER |
| Owner: PALM COAST SPECIALISTS, LTD |
|
Address 595 W. GRANADA BLVD ORMOND BEACH, FL 32174 |
| Lot: 20 |
| Contracted Stated Job Value: ¤8,000,000.00 |
| Job Description: SHELL / CORE FOR MEDICAL OFFICE/CLINIC |
| Type: CN |
Contractor
STELLAR GROUP INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
2900 HARTLEY ROAD JACKSONVILLE, FL 32257 |
CGC052029 (Exp: 08/31/2024) | 904-899-9214 |
Sub Contractors
RONALD A AUTREY
| Status | Location Address | State License Number | Phone |
| CANCEL |
PO Box 1799 Jacksonville, Fl., 32201 |
ECOOOO388 (Exp: 08/31/2018) | (904) 388-8000 |
GARY S WELBORN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1709 North Nova Road Holly Hill, FL 32117 |
CFC037140 (Exp: 08/31/2018) | (386) 257-1172 | (386)252-5979 |
ANTHONY JAMES PARETE
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
6900 PHILLIPS INDUSTRIAL BLVD. JACKSONVILLE, FL 32256 |
CCC044057 (Exp: 08/31/2026) | (904)880-6005 | (904)880-3377 |
TIMOTHY ERIC HOLCOMB
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
101 MUNDY MEMORIAL DRIVE , TN 37122 |
CMC1249492 (Exp: 09/30/2008) | (800)222-1819 | (615)773-8108 |
WAYNE M WILHELM
| Status | Location Address | State License Number | Phone |
| CANCEL |
PO BOX 530427 DEBARY, FL 32713 |
09834200012000 (Exp: 06/30/2022) | (386)668-8719 |
DENNIS BISHOP
| Status | Location Address | State License Number | Phone |
| CANCEL |
522 Stockton Street Jacksonville, FL 32204 |
76693700011990 (Exp: 06/30/2013) | (904) 387-7973 |
WILLIAM W GAY
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
524 STOCKTON STREET JACKSONVILLE, FL 32204 |
CMC008140 (Exp: 08/31/2020) | (904)388-2696 | 904-394-7944 |
JOHN W BARBER JR
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1514 BERNITA STREET JACKSONVILLE, FL 32211 |
CCC057141 (Exp: 08/31/2020) | (904)744-4067 | (904)744-4209 |
Inspection History
| Type | Request Date | Result | Inspector |
| ENGINEERING FINAL | 04/14/2008 | APPROVED | MIKE COBB |
| TRAFFIC ENGINEER | 04/11/2008 | FINAL APPROVED | PHONG |
| Note: per MB | |||
| LANDSCAPE FINAL | 04/09/2008 | APPROVED | WBUTLER |
| FIRE FINAL | 04/02/2008 | APPROVED | JPATTEE |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 03/31/2008 | CANCELLED BY APPLICANT | JPATTEE |
| UTILITY COMMERCIAL FINAL | 03/31/2008 | APPROVED | TSCHWEERS |
| Note: Gravity ok, no permit to sign. | |||
| UTILITY COMPANY FINAL | 03/28/2008 | APPROVED | DSPENCER |
| UTILITY COMMERCIAL FINAL | 03/28/2008 | APPROVED | DSPENCER |
| FINAL COMPLETE BUILDING INSPECTION | 03/28/2008 | FINAL APPROVED | JLEVRAULT |
| STORMWATER FINAL INSPECTION | 03/28/2008 | CANCELLED BY INSPECTOR | LAPTEKAR |
| Note: This inspection will be handled by the Engineering Dept with the Engineering Final when all the required documents have been submitted...call 986-3794 for information. | |||
| ELECTRICAL FINAL | 03/27/2008 | APPROVED | RMARVEL |
| H.V.A.C. FINAL | 03/26/2008 | APPROVED | JLEVRAULT |
| FIREWALL INSPECTION 3ND ROUGH | 03/25/2008 | APPROVED | JLEWIS |
| Note: THIS IS A REINSPECTION | |||
| H.V.A.C. ROUGH | 03/24/2008 | APPROVED | JLEVRAULT |
| Note: LAST SECTION IN THE COMMON CORRIDOR APPROVED. | |||
| THRESHOLD/AFFIDAVIT | 03/20/2008 | APPROVED - AS NOTED | JMCGOWEN |
| Note: threshold inspections by universal on file | |||
| PLUMBING FINAL | 03/20/2008 | FINAL APPROVED | PGALLMANN |
| FRAMING | 03/04/2008 | APPROVED - AS NOTED | CMINI |
| Note: REVISED DOORS ADDED ON PRINT FRAMING PART. | |||
| ABOVE CEILING | 02/19/2008 | APPROVED - AS NOTED | JLEVRAULT |
| Note: THIS IS A REINSPECTION NORTH WEST COMMON CORRIDOR ENDING AT BUT NOT INCLUDING ELEVATOR. | |||
| ABOVE CEILING | 02/18/2008 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: HOLE CUT IN FIRE RATED WALL IN CORRIDOR. | |||
| ABOVE CEILING | 02/11/2008 | PARTIALLY APPROVED | JLEVRAULT |
| Note: ALL BUT 40 FEET OF WEST END CORRIDOR. | |||
| FIREWALL INSPECTION | 01/22/2008 | APPROVED | JPATTEE |
| H.V.A.C. ROUGH | 01/18/2008 | APPROVED - AS NOTED | JLEVRAULT |
| Note: VESTIBULE HARD CEILING AREA. | |||
| 2ND ROUGH ELECTRICAL | 01/18/2008 | APPROVED | LHITES |
| Note: THIS IS INSPECTION WAS FOR THE MAIN ENTRANCE CEILING | |||
| FRAMING | 01/18/2008 | APPROVED - AS NOTED | JLEVRAULT |
| Note: VESTIBULE AREA HARD CEILING FRAMING. | |||
| FIREWALL INSPECTION 3ND ROUGH | 01/14/2008 | Disapproved - NO FEE | JPATTEE |
| FRAMING | 01/10/2008 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: NEED REVISION FOR FRONT ENTRY | |||
| FRAMING | 01/02/2008 | PARTIALLY APPROVED | JHINDMAN |
| Note: ENTRY SOFFITS | |||
| ABOVE CEILING | 01/02/2008 | APPROVED | RMARVEL |
| ABOVE CEILING | 12/21/2007 | PARTIALLY APPROVED | JLEVRAULT |
| Note: FIRST FLOOR MAIN LOBBY CEILING | |||
| FRAMING | 12/19/2007 | PARTIALLY APPROVED | JHINDMAN |
| Note: LOBBY FRAMING | |||
| H.V.A.C. ROUGH | 12/17/2007 | APPROVED | JLEVRAULT |
| Note: SUPPLY ANT RETURN DUCTWORK IN MAIN CORRIDOR. | |||
| INSULATION INSPECTION | 12/12/2007 | Disapproved -FEE REQUIRED | CMINI |
| Note: MISSING INSULATION IN FRONT WALL CORNER. | |||
| INSULATION INSPECTION | 12/12/2007 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION... ENTIRE FRONT WALL O.K. OF FRONT ENTRANCE EXCEPT OVER WINDOW WHERE MATERIALS ARE BROUGHT IN..... | |||
| SECOND ROUGH PLUMBING INSPECTION | 12/11/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS WAS FOR SAME INSPECTION AS YESTERDAY WHICH WAS APPROVED | |||
| SECOND ROUGH PLUMBING INSPECTION | 12/10/2007 | APPROVED | JGIBSON |
| INSULATION INSPECTION | 12/10/2007 | PARTIALLY APPROVED | CMINI |
| Note: FRONT WALL OF MAIN ENTRANCE OK.......NEED TO INSPECT BEAM CHANNEL AT FRONT WALL AND AT STAIRS....2ND FL. COMMON BATH ROOMS O.K.ABOVE FRONT WINDOW WHERE LOADING MATERIALS NEEDS TO BE INSPECTED.... | |||
| INSULATION INSPECTION | 12/07/2007 | PARTIALLY APPROVED | JHINDMAN |
| Note: UNDER MAIN STAIRS, UPSTAIRS FROM TOP OF STAIRS TO FRONT WAA AT CAFE | |||
| FIRE SYSTEM FLUSH | 12/07/2007 | APPROVED | JPATTEE |
| 2ND ROUGH ELECTRICAL | 12/07/2007 | APPROVED | JHINDMAN |
| 2ND ROUGH ELECTRICAL | 12/03/2007 | APPROVED | LHITES |
| Note: UNIT 220 ENTRY BATHROOMS WALLS ONLY | |||
| SECOND ROUGH PLUMBING INSPECTION | 12/03/2007 | APPROVED | JGIBSON |
| H.V.A.C. ROUGH | 11/29/2007 | PARTIALLY APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION RECEPTION AREA SUPPLY AND RETURN DUCTS FROM ROOF TO CORRIDOR WALL. | |||
| INSULATION INSPECTION | 11/27/2007 | PARTIALLY APPROVED | JHINDMAN |
| Note: ELEVATOR EQUIPT ROOM | |||
| ABOVE CEILING | 11/27/2007 | PARTIALLY APPROVED | JLEVRAULT |
| Note: LOBBY CEILING. | |||
| H.V.A.C. ROUGH | 11/26/2007 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: CALLED IN WRONG INSPECTION. | |||
| 2ND ROUGH ELECTRICAL | 11/26/2007 | APPROVED | LHITES |
| Note: SECOND FLOOR HARD CEILING AND DOMED CEILING AREAS | |||
| STEM FOOTING FOUNDATION | 11/15/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: CALLED IN UNDER WRONG PERMIT | |||
| FRAMING | 11/13/2007 | PARTIALLY APPROVED | JHINDMAN |
| Note: COMMON AREA UPSTAIRS BATHROOMS | |||
| 2ND ROUGH ELECTRICAL | 11/13/2007 | APPROVED | LHITES |
| Note: SHORT BREEZEWAY BETWEEN BUILDINGS | |||
| INSULATION INSPECTION | 11/13/2007 | PARTIALLY APPROVED | JHINDMAN |
| Note: TOP OF COMMON AREA AT ROOF CENTRAL TOWER | |||
| H.V.A.C. ROUGH | 11/09/2007 | PARTIALLY APPROVED | JLEVRAULT |
| Note: FIRST FLOOR EAST MAIN LOBBY DUCTWORK. | |||
| 2ND ROUGH ELECTRICAL | 11/06/2007 | APPROVED | LHITES |
| Note: EXTERIOR HARD LID CEILINGS ELECTRIC | |||
| INSULATION INSPECTION | 11/01/2007 | PARTIALLY APPROVED | JHINDMAN |
| Note: CORREDOR WALL OUTSIDE 265 | |||
| INSULATION INSPECTION | 10/22/2007 | PARTIALLY APPROVED | JHINDMAN |
| Note: WEST TOWER 2ND FLOOR OK | |||
| COMMERCIAL POWER INSPECTION | 10/16/2007 | APPROVED | LHITES |
| FRAMING | 10/08/2007 | PARTIALLY APPROVED | JHINDMAN |
| Note: FRONT ENTRY | |||
| COMMERCIAL POWER INSPECTION | 10/04/2007 | APPROVED | LHITES |
| INSULATION INSPECTION | 09/28/2007 | PARTIALLY APPROVED | JHINDMAN |
| Note: BREEZEWAY WEST SIDE | |||
| INSULATION INSPECTION | 09/19/2007 | PARTIALLY APPROVED | JHINDMAN |
| Note: TOWERS 2 AND 3 | |||
| H.V.A.C. ROUGH | 09/12/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: EXPOSED DUCTWORK ON ROOF. | |||
| H.V.A.C. ROUGH | 09/07/2007 | PARTIALLY APPROVED | JLEVRAULT |
| Note: DUCT INSULATION ABOVE HARD CEILING IN WALKWAY 1032. | |||
| COMMERCIAL POWER INSPECTION | 08/27/2007 | APPROVED | LHITES |
| H.V.A.C. ROUGH | 08/24/2007 | APPROVED - AS NOTED | JMCGOWEN |
| Note: CANOPY MAKE UP AIR DUCTS. | |||
| H.V.A.C. ROUGH | 08/22/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: ROOFTOP DUCTWORK NEAR FIREWALL IN EAST CORRIDOR ON THE WEST HALF. | |||
| H.V.A.C. ROUGH | 08/21/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: NORTHWEST CORRIDOR DUCTWORK. | |||
| H.V.A.C. ROUGH | 08/17/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: SECOND FLOOR EAST SIDE CORRIDOR DUCTWORK AT FIREWALL. | |||
| FIRE SPRINKLER 2ND ROUGH HYDROSTATIC PRESSURE TEST | 08/15/2007 | APPROVED | JLEWIS |
| Note: units 230-280 | |||
| H.V.A.C. ROUGH | 07/26/2007 | APPROVED | JLEVRAULT |
| 2ND ROUGH ELECTRICAL | 07/25/2007 | APPROVED | LHITES |
| Note: ENTRY CANOPY AND FRONT 2 COLUMNS | |||
| INSULATION INSPECTION | 06/28/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: partial electric rooms, fire riser room, common rooms east side of building. | |||
| LATH /BRICK FLASHING | 06/22/2007 | APPROVED | JHINDMAN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/31/2007 | CANCELLED BY APPLICANT | JHINDMAN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/22/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: conopy complete | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/07/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: CANOPY AND EYEBROW ROOF DECKING | |||
| LINTEL | 05/07/2007 | APPROVED | JHINDMAN |
| Note: LINTELS COMPLETE | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 04/26/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: 2ND FLOOR SLAB WEST WING | |||
| LINTEL | 04/23/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: GENERATER WALLS | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 04/19/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: 2ND FLOOR SLAB MAIN BUILDING | |||
| STEM FOOTING FOUNDATION | 04/17/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: GENERATER WALL | |||
| FOOTER | 04/11/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: per the request of Matthew STAIR FOOTERS. | |||
| LINTEL | 04/11/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: ELEVATOR LINTELS SECOND LIFT | |||
| FOOTER | 04/09/2007 | Disapproved - NO FEE | JLEVRAULT |
| Note: REVISION NEEDS TO BE APPROVED BY PLANS DEPT. | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 04/03/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: APPROVED SIX EXTERIOR PORCH SLABS. HILITED AND DATED ON JOB PLANS. | |||
| TEMPORARY POLE | 04/03/2007 | APPROVED | LHITES |
| Note: CALLED FPL 4/3 | |||
| LINTEL | 03/30/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: 1ST LIFT | |||
| FOOTER | 03/27/2007 | APPROVED | JHINDMAN |
| Note: | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 03/22/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: SLAB POURBACKS | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 03/21/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: PARTIAL POURBACK | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 03/15/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: INTERIOR SLABS | |||
| POURED CELL | 03/12/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: elevator shaft wall | |||
| ELEVATOR CERTIFICATION INSPECTION | 03/12/2007 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: called in by mistake | |||
| FIRE MAIN-HYDROSTATIC / BACKFLOW PREVENTERS | 03/09/2007 | APPROVED | JPATTEE |
| FIRE MAIN PLACEMENT, SIZE, THRUST BLOCKING UNCOVERED INSPECTION | 03/08/2007 | APPROVED | BMEYERS |
| LINTEL | 02/08/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: tiltwall complete | |||
| LINTEL | 02/06/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: TILTWALL PARTIAL | |||
| FOOTER | 02/06/2007 | APPROVED | JHINDMAN |
| Note: | |||
| LINTEL | 02/01/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: PARTIAL TILTWALL | |||
| LINTEL | 01/31/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: PARTIAL TILTWALL PANELS | |||
| LINTEL | 01/29/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: PARTIAL TILTWALL | |||
| LINTEL | 01/24/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: PARTIAL TILTWALL SECTIONS | |||
| UNDERGROUND ELECTRICAL | 01/24/2007 | APPROVED | RMARVEL |
| LINTEL | 01/23/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: TILTWALL PARTIAL | |||
| LINTEL | 01/22/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: PARTIAL TILTWALL PANELS | |||
| LINTEL | 01/16/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: TILTWALL PANELS, PARTIAL | |||
| RETAINING WALL | 01/11/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: tilt wall panels, partial | |||
| RETAINING WALL | 01/10/2007 | APPROVED - AS NOTED | DROCKWELL |
| Note: Partial o.k | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 01/10/2007 | APPROVED - AS NOTED | JHINDMAN |
| Note: partial o.k | |||
| FIRST ROUGH PLUMBING INSPECTION | 01/09/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: All plumbing under-ground completed in all units. | |||
| FIRST ROUGH PLUMBING INSPECTION | 01/03/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: All under ground plumbing is completed except vacume lines on unit 180, all under ground plumbing that has been inspected is approved according to site plan which is what was submitted to plan review and will be approved accordingly. PER Larry Woodrom and Mark Gibson. | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 12/22/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: THIS IS A REINSPECTION partial east wing | |||
| FIRST ROUGH PLUMBING INSPECTION | 12/21/2006 | APPROVED - AS NOTED | JGIBSON |
| Note: Front bath-room group only common bath-rooms | |||
| FOOTER | 12/21/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: THIS IS A REINSPECTION partial see plans for locations | |||
| FOOTER | 12/20/2006 | CANCELLED BY APPLICANT | JHINDMAN |
| FOOTER | 12/19/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: see plans for locations | |||
| FIRST ROUGH PLUMBING INSPECTION | 12/19/2006 | APPROVED - AS NOTED | JGIBSON |
| Note: Unit 130 ok for test on build out underground. | |||
| FIRST ROUGH PLUMBING INSPECTION | 12/15/2006 | APPROVED - AS NOTED | JGIBSON |
| Note: First rough plumbing tested on units 110,120,130. Partial inspection on units 130---Bath room groups not roughed in yet. | |||
| FIRST ROUGH PLUMBING INSPECTION | 12/14/2006 | APPROVED - AS NOTED | JGIBSON |
| Note: Units 120-110 sanitary plumbing OK not yet tested will be checked at a later day. | |||
| FOOTER | 12/14/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: SEE PLANS | |||
| FOOTER | 12/13/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: PARTIAL FOOTINGS HIGHLIGHTED ON PLANS FOR LOCATIONS | |||
| FOOTER | 12/11/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: FOOTINGS PARTIAL SEE PLANS | |||
| FOOTER | 12/07/2006 | APPROVED - AS NOTED | JLEVRAULT |
| Note: PARTIAL FOOTING AND PADS - HILITED AND DATED ON JOB PLANS IN ORANGE. | |||
| FOOTER | 12/06/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: PARTIAL, FOOTING PADS | |||
| FOOTER | 12/05/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: 1 elevator pit | |||
| FOOTER | 12/01/2006 | APPROVED - AS NOTED | JHINDMAN |
| Note: PARTIAL | |||
| TEMPORARY POLE | 11/30/2006 | APPROVED | LHITES |
| Note: CALLED FPL ON 11/30/06 | |||
| FOOTER | 11/28/2006 | APPROVED | JHINDMAN |
| MONOLITHIC SLAB INSPECTION/SLAB | 11/28/2006 | CANCELLED BY APPLICANT | JHINDMAN |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 03/25/2008 | 03/25/2008 |
| Note: Released By: SKNOPF Approved for Release. Revision: Various electrical changes (see Electrical Comments 3-6-2008). Released per L.W. | |||
| ELEC | HOLD | 03/05/2008 | 03/06/2008 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Permit #2006090629 (Town Center Medical @ 21 Hospital Dr.) 3/6/2008 The following items must be resolved in order to complete the Building Permit plan review. 2 sets of as-builts Electrical Comments: 1. E001 and E701 - E001 Shows multiple type 'G2' fixtures. Fixture Schedule E701 does not give load for this fixture type. Provide load for Fixture Type 'G2' for load calculation verification. 2. E001A and E701 - Monument sign details show fixture type 'G1' at all monument signs. Fixture Schedule E701 does not depict this fixture type. Please identify fixture type and load. 3. E105 - Shows temporary lighting in future tenant 240 and exit lighting in tenant 230 on circuit 3. Please identify panel for this circuit. 4. E201 and E701 - Detail Enlarged Elevator Room - shows Elevator Control Panel as circuit HR2-20. Panel Schedule for HR2-20 E701 shows this as a 1P 20A circuit breaker for EF1 and receptacles in Elevator room. Review and revise. 5. E202: a. EWH-2-9-A shows a circuit of HR-30. HR-30 in panel schedule is one leg of a 3 phase circuit for CU-1-9-A. Please reference circuit HR-15. Review and revise. b. Detail 1 Wiring Diagram this sheet for mini-split and Sheet E701 circuit HR-35 both indicate a new mini-split. Both Mechanical and Electrical plans do not show a mini-split. Please clarify location of this unit if unit is still required, or revise plans and panel to delete reference. If unit is no longer relative, revise circuit breaker for HR-35 for protection of AHU-1-9-A. c. AHU-1-13-A is shown with no circuit. Review and revise. 6. E205 - Shows (4) receptacles in future tenant 230 and 240 on circuit HR-3. Panel schedule shows this circuit is a lighting contactor and timeclock, with no load shown. Please review and revise. 7. E501: a. Enlarged Electrical and EM Electrical - shows FACP with no power circuit. Please review and revise. b. Enlarged Elevator Floor Plan Elevators #1 and #2 - shows EF-1-9-C in room 1005 has no circuit. Identify circuit and update panel schedule with load. 8. E601, E602 and E701: a. Riser E601 and E602 shows Panel HP as a 500A MCB panelboard. E701 Panel Schedule shows this panel as a 600A MCB panelboard. Please review and revise. b. Riser E601 and E602 shows a 75KVA transformer feeding Panel HR. Maximum amperage on the load side of this transformer is 208A. Panel HR on E701 is showing total load as 78.6KVA yielding 218A. Please review and revise and provide load calculation on panel to determine required size of panel and feeder. 9. E601 and E701 - Riser E601 shows Panel HP2 as a 225A MCB panelboard. E701 panel schedule shows it as a 200A MCB panelboard. Please review and revise. 10. E701: a. Panel HP circuits 31 and 33 have no load shown for lighting per their description. Review and revise. b. Panel HP2: 1) Circuit 20 has no load shown for flagpole lighting. Review and revise. 2) Circuits 2, 6, and 12 have undersized loads. Please review and revise. c. Panel HR2: 1) Circuits 2, 4, 10, 12, 13, 14, 18, 19 and 20 have no loads for their descriptions. Review and revise. 2) Circuit HR2-10 shows an irrigation controller, but this circuit also appears for Lobby 1012 receptacle. Please review and revise load. d. It was noted during review that Elevator #4 (Panel HP), Elevator #3 (Panel HP2), and Elevator #1 (Panel HR2) all have different KVA loads. Please review and revise as necessary. e. Please review AHU/CU/RTU loads. Some of the loads in the respective panels appear to be undersized when compared to Sheet M001 schedules. Please review and revise. f. Luminaire Schedule - The following fixtures have no load shown in schedule: 'EM', 'M', 'N', 'O', 'P', 'PE', 'Z1', 'DE', 'RECE'. Provide load for each fixture type. g. Load Calculation for Common Area does not clearly identify demands nor does it match Panel HP. Please revise load calculation for Panel and Service feeder verification. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | COMPLETE | 02/13/2008 | 02/13/2008 |
| Note: Released By: FREODICA 1. Revisions approved for release on mech., arch., & Plmb. Electrical still on hold. 2. Revised sheets are as follows: G102, A105 thru A108, A113, A114, A208, A209, A312, A400, A602, A603, A605, M001, M101 to M104, & P101. | |||
| BLD | COMPLETE | 01/22/2008 | 01/23/2008 |
| Note: Released By: FREODICA Rev.- Structural - Sheets S102, S104 & S230. | |||
| BLD | HOLD | 01/15/2008 | 01/22/2008 |
| Note: Held By: FREODICA Electrical Comments: 1. Sheet E001A: a. Signs require separate permits, and site changes shown require a development order before building plan review. 2. Sheet E102: a. No circuit shown for fixtures in Elevator #4 and Elevator Equipment Room #1018. Provide circuit and additional load in panel schedule. 3. Sheet E202: a. This sheet shows both AHU-1-9-A and CU 1-9-A as 1Ph 2Pole from circuit HR-35. Mechanical schedule for both AHU and CU on sheet M001 shows both pieces of equipment as 208V 3Ph. Please coordinate drawings and revise. 4. General Notes: a. Please reference other permit and plans on any sheets where circuits for Panel 'LSP" appear for coordination of drawings. b. Please update panel schedules for load description and VA. Mechanical Comments: 1. Sheet M001: Supply air in CFM of AHU-1-9-A does not match the CFM on Equipment Schedule. 2. Sheet M103: Supply air in CFM of RTU-2-9-A does not match the CFM on Equipment Schedule. 3. Sheet M104: Supply air in CFM of RTU-2-10-A does not match with the CFM on Equipment Schedule. Plumbing: 1. Sheet P101: Provide condensate size and material of condensate drain from AHU-1-13-A. Note: All revised architectural drawings submitted are approved for release. | |||
| BLD | COMPLETE | 11/16/2007 | 11/16/2007 |
| Note: Released By: LWOODROME | |||
| BLD | COMPLETE | 07/31/2007 | 07/31/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Water heater ceiling hung change. | |||
| BLD | COMPLETE | 05/03/2007 | 05/03/2007 |
| Note: Released By: LWOODROME Revision: Fireproofing changed to UL#D902 (Product name Blaze shield) | |||
| BLD | COMPLETE | 04/05/2007 | 04/10/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Add footings for exterior stairs on North Side. | |||
| FD1 | COMPLETE | 03/19/2007 | 03/22/2007 |
| Note: Released By: JPATTEE W.W. GAY FIRE & INTEGRATED SYSTEM BROUGHT IN PLANS TO BE REVIEWED, HE WAS ADDED AS A SUB FOR THE FIRE SPRINKLER (THIS IS NOT FOR UNDERGROUND) | |||
| FD1 | COMPLETE | 02/15/2007 | 03/22/2007 |
| Note: Sunstate - Fire Underground Released By: JPATTEE | |||
| BLD | COMPLETE | 02/02/2007 | 02/06/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Toilet Stall door layout. | |||
| BLD | COMPLETE | 01/19/2007 | 01/22/2007 |
| Note: Released By: CCOTE Met with Andy. Submitted additional revision items and modified sheets for original revision. Approved for Release. 4 HOURS OF REVIEW TIME REVISION: Misc changes. | |||
| BLD | HOLD | 12/18/2006 | 01/02/2007 |
| Note: Held By: CCOTE CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2006090629 (Town Center Medical) The following items must be submitted/clarified in order to complete the Building Department Revision plan review for this permit All future revision submissions shall only include revised sheets. In addition provide a detailed summary of the revision(s) as well as a cloud around the specific area/item that was revised. Generic notes and clouding of overall areas are not sufficient. 1. Cover Sheet: Architectural sheet list appears to have sheet A604 & A605 as new sheets. Please clarify that these were the only 2 added sheets for this revision. 2. Cover Sheet: Structural sheet list for revision C states that a sheet was added however no structural sheets could be found with this revision. 3. Sheet G101: A cloud was added to drop-off area and noted as revision b however revision b was part of the original permit drawings. Please clarify if any revisions were made and if so they need to be identified and noted as revision c. 4. Sheet G102: No changes appear to be made to this sheet. Please review and identify if changes were made. 5. Sheet G103: Title block indicates a revision b however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision b line from title block. 6. Sheet G104: Title block indicates a revision b however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revise b line from title block. 7. Civil/Landscape Sheets: These drawings are not reviewed by the building department and will require review by other City Departments who at that time may have comments regarding these sheets. 8. Sheet A101: No changes appear to be made to this sheet. Please review and identify if changes were made. 9. Sheet A102: Provide UL Assembly Number(s) for enclosing columns within fire rated walls. 10. Sheet A103: No comment. 11. Sheet A103A: Provide UL Assembly Number(s) for enclosing columns within fire rated walls. 12. Sheet A104: No comment. 13. Sheet A105: No changes appear to be made to this sheet except for adding of revision c to the title block. Please review and identify if changes were made. 14. Sheet A106: No changes appear to be made to this sheet. Please review and identify if changes were made. 15. Sheet A107: No changes appear to be made to this sheet. Please review and identify if changes were made. 16. Sheet A108: No changes appear to be made to this sheet. Please review and identify if changes were made. 17. Sheet A109: No comment. 18. Sheet A110: No comment. 19. Sheet A111: No changes appear to be made to this sheet. Please review and identify if changes were made. 20. Sheet A113: No revision indicated however it appears that the ceiling layout changed. Please review and identify change made and add revision d. 21. Sheet A114: No revision indicated however it appears that changes were made. Please review and identify change(s) made and add revision d. 22. Sheet A115: No comment. 23. Sheet 201: No comment. 24. Sheet 202: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 25. Sheet A203: No comment. 26. Sheet A204: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 27. Sheet A205: No comment. 28. Sheet A206: No comment. 29. Sheet A300: No comment. 30. Sheet A300A: No comment. 31. Sheet A301: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 32. Sheet A302: No comment. 33. Sheet A303: No comment. 34. Sheet A310: No comment. 35. Sheet A311: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 36. Sheet A312: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 37. Sheet A400: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 38. Sheet A401: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 39. Sheet A402: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 40. Sheet A403: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 41. Sheet A404: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 42. Sheet A405: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 43. Sheet A501: Rooms 1001 & 1002 do not comply with Florida Building Code stating that the stall door shall not swing into the clear space of any fixture. Refer to Figure 30e in the Building Code. 44. Sheet A501: General note is unclear where it states ….clear 8. Floor space….. Please review and revise as required. 45. Sheet A600: No comment. 46. Sheet A601: No comment. 47. Sheet A602: No comment. 48. Sheet A602A: Title block indicates a revision b however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision b line from title block. 49. Sheet A603: Title block indicates a revision c however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision c line from title block. 50. Sheet A604: No comment. 51. Sheet A605: No comment. 52. Sheet M001: No comment. 53. Sheet M101: Work that is not part of this shell permit is shown and should be removed (ceiling grids, lighting, etc.). 54. Sheet M102: Items shown that are not labeled. Either remove items are add notes. 55. Sheet M103: Work that is not part of this shell permit is shown and should be removed. EDH??? 56. Sheet M104: Supply and return diffusers are shown on this drawing with no ductwork connected to them. This work is not part of this shell permit and should be removed. Title block indicates a revision b however no areas on the drawings appear to be made or are clouded. Please review and identify if changes were made if no changes were made then remove revision b line from title block. 57. Sheet M105: There is a note on plan "Dryer Gooseneck Suite 120" however there is nothing shown adjacent to this note. Review and remove note or add/show/describe work to be done. 58. Sheet M106: Both mechanical units shown indicate "(by others)". These units are shown on the mechanical schedule as being part of this shell building permit. Please review and clarify item. 59. Sheet M501: No Comment. 60. Sheet P001: No Comment. 61. Sheet P101: No Comment. 62. Sheet P102: No Comment. 63. Sheet P103: Work that is not part of this shell permit is shown and should be removed. EDH??? 64. Sheet P104: No Comment. 65. Sheet P801: No Comment. 66. Sheet P802: No Comment. 67. Sheet P803: No Comment. 68. Sheet P804: No Comment. 69. Sheets E001-1-2: These drawings are not reviewed by the building department and will require review by other City Departments who at that time may have comments regarding these sheets. 70. Electrical Sheets: No Comment. ------------------------------------------------- Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us ------------------------------------------------- 4 HOURS OF REVIEW TIME | |||
| BLD | COMPLETE | 11/28/2006 | 12/14/2006 |
| Note: Released By: LWOODROME Revisions: structural, tilt-up panels and details | |||
| BLD | COMPLETE | 10/13/2006 | 10/23/2006 |
| Note: Released By: LWOODROME | |||
| FI1 | COMPLETE | 11/09/2006 | |
| Note: Released By: JPATTEE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REVISION | ¤400.00 | 04/04/2008 |
| REVISION | ¤40.00 | 04/04/2008 |
| REVISION | ¤80.00 | 04/04/2008 |
| REVISION | ¤40.00 | 04/04/2008 |
| REVISION | ¤80.00 | 04/04/2008 |
| REVISION | ¤40.00 | 04/04/2008 |
| REVISION | ¤40.00 | 04/04/2008 |
| REVISION | ¤40.00 | 04/04/2008 |
| REVISION | ¤80.00 | 04/04/2008 |
| REVISION | ¤320.00 | 04/04/2008 |
| REVISION | ¤40.00 | 04/04/2008 |
| ADDITIONAL FEE | ¤40.00 | 04/04/2008 |
| ADDITIONAL FEE | ¤40.00 | 04/04/2008 |
| FIRE SPRINKLER FEE | ¤79.37 | 04/16/2007 |
| PERMIT FEE | ¤40.00 | 04/16/2007 |
| PROCESSING FEE - FIRE | ¤50.00 | 04/05/2007 |
| FIRE UNDERGROUND | ¤75.00 | 04/05/2007 |
| FIRE PLANS REVIEW | ¤822.90 | 11/27/2006 |
| MECHANICAL FEE | ¤4,830.00 | 11/27/2006 |
| PERMIT FEE | ¤44,000.00 | 11/27/2006 |
| ADMIN FEE | ¤20.00 | 11/27/2006 |
| BUILDING CODE ADMIN FUND | ¤411.45 | 11/27/2006 |
| ELECTRIC FEE | ¤4,830.00 | 11/27/2006 |
| FIRE COMM IMPACT FEE 4-1-05 | ¤40,906.36 | 11/27/2006 |
| RADON FEE | ¤411.45 | 11/27/2006 |
| PLAN CHECK FEE | ¤9,200.00 | 11/27/2006 |
| PLUMBING FEE | ¤4,830.00 | 11/27/2006 |
| TRANSPORTATION IMPACT FEE | ¤735,523.65 | 11/27/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤847,510.18 |