I want to search for...
Permit #2006090637
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7033-00390-0050 |
| PATIO/DECK (NO ROOF) : 369 sqft |
| Block: 00390 |
| Subdivision: - |
| Job Phone: (386)774-9191 |
| Location Address: 101 RENSHAW DR |
| Type: PO - POOL |
| Issue Date: 10/12/2006 |
| NOC: RECORDED |
| Applicant name: WILLIAM F COODY |
| Owner: LOWRY CASEY L & TINA M H&W |
|
Address 101 RENSHAW DRIVE PALM COAST, FL 32164 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤22,000.00 |
| Job Description: POOL WITH SCREEN ENCLOSURE |
| Type: CN |
Contractor
BILL COODY CUSTOM POOLS INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
620 S VOLUSIA AVE ORANGE CITY, FL 32774 |
CPC1456731 (Exp: 08/31/2016) | (386)774-9191 | (386)774-9194 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL - FINAL | 03/28/2007 | FINAL APPROVED | JHINDMAN |
| Note: | |||
| POOL - FINAL | 03/23/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: BY THE CONTRACTOR TIMECLOCK SUBPANEL HAS 50 AMP BEAKER FOR SPA THAT IS NOT SHOWN ON PERMIT, WHAT SIZE CONDUCTOR IS FEEDING SUBPANEL? ELECTRICAL JUNCTION BOX ON WALL HAS OPEN KNOCKOUT IN SIDE OF IT. POOL VENT PIPE MISSING SCREEN ON EAST SIDE OF HOUSE. | |||
| STORMWATER FINAL INSPECTION | 03/19/2007 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 3 / 19 / 07 | |||
| UTILITY COMPANY FINAL | 03/16/2007 | APPROVED | MBACON |
| STORMWATER FINAL INSPECTION | 03/12/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: THIS IS A REINSPECTION REMOVE WOOD AND SWING SET . | |||
| STORMWATER FINAL INSPECTION | 03/09/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: remove all form boards from left adj. property | |||
| UTILITY COMPANY FINAL | 02/21/2007 | APPROVED | MBACON |
| POOL DECK INSPECTION | 11/01/2006 | APPROVED | PGALLMANN |
| STEEL & GROUND | 10/13/2006 | APPROVED | JMCGOWEN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/06/2006 | 10/10/2006 |
| Note: Released By: CCOTE Approved for Release. Review by Auba. | |||
| ZON | COMPLETE | 09/28/2006 | 10/06/2006 |
| Note: Released By: ECOYNE |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 03/27/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 03/22/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 03/22/2007 |
| ARC POOL/SCREEN REVIEW | ¤50.00 | 10/12/2006 |
| ELECTRIC FEE | ¤43.20 | 10/12/2006 |
| PERMIT FEE | ¤132.00 | 10/12/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤335.20 |