I want to search for...

Permit #2006100125

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7027-00270-0150
PATIO/DECK (NO ROOF) : 808 sqft
Total Square Footage: 1200 sqft
Block: 00270
Subdivision: -
Job Phone: (386)736-2828
Location Address: 41 WOODLAWN DR
Type: PO - POOL
Issue Date: 10/20/2006
NOC: RECORDED
Applicant name: KEITH LANPHEAR
Owner: APPOLLON, JOSEPH A & CARINE T

Address

41 WOODLAWN DRIVE

PALM COAST, FL 32164

Lot: 0150
Contracted Stated Job Value: ¤40,500.00
Job Description: IN-GROUND POOL & SPA WITH A SCREEN ENCLOSURE
Type: CN

Contractor

FREEDOM HOMES POOLS & SPAS INC.
Status Location Address State License Number Phone Fax
CANCEL

2001 LARACHMONT DRIVE

DELAND, FL 32724

CPC025522 (Exp: 09/30/2008) (904)824-8499 (386)734-8070

Sub Contractors

THOMAS M HENRY
Status Location Address State License Number Phone Fax
INACTIVE

85-B S. HWY.17-92

DE BARY, FL 32713

EC0002683 (Exp: 08/31/2026) (386)668-0691 (386)668-8908

Inspection History

Type Request Date Result Inspector
POOL - FINAL 11/28/2007 FINAL APPROVED ACOOPER
Note: THIS IS A REINSPECTION REQUESTED BY OWNER OK TO CHANGE NOC DATE BY BARBIE
POOL - FINAL 07/18/2007 Disapproved - NO FEE PGALLMANN
Note: THIS IS A REINSPECTION... ADDITIONAL DEFICIENCIES NOTED AT TIME OF REINSPECTION: 1) THE TWO EQUIPMENT SLABS (CEMENT PLASTER OVER STYROFOAM) HAVE FAILED/SETTLED AND BROKE IN HALFS. PER CODE, THE EQUIPMENT SLAB/S MUST BE POURED SLAB/S, SIX INCHES LARGER THAN THE EQUIPMENT ON ALL SIDES. NOTE: UPLIFT STRAPPING MUST BE INSTALLED FROM SLAB TO GAS FIRED POOL HEATER. 2) TEMPERATURE RELIEF VALVE IS MISSING FROM POOL HEATER. THE MANUFACTURER PROVIDED A 3/4" FEMALE IRON PIPE TAPING IN THE HEAT EXCHANGER FOR RELIEF VALVE INSTALLATION.
POOL - FINAL 06/29/2007 Disapproved -FEE REQUIRED MMOORE
Note: Keith came in to schedule vent screens missing. adjust both doors. cable is 45% backwards.
UTILITY COMPANY FINAL 05/23/2007 APPROVED TSCHWEERS
Note: NO PERMIT TO SIGN
STORMWATER FINAL INSPECTION 04/12/2007 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 01/10/2007 Disapproved -FEE REQUIRED DRANDALL
Note: regrade property swale, to flow properly, and resod same area.....remove trash, & debris from across street adj. property and swale, regrade, & sod city right of way, seed & straw all exposed earth beyond new sod
POOL DECK INSPECTION 11/14/2006 APPROVED ACOOPER
STEEL & GROUND 11/06/2006 APPROVED ACOOPER

Review History

Department Status Date In Date Out
BLD COMPLETE 10/19/2006 10/20/2006
Note: Released By: CCOTE Approved for Release. Review by Auba.
ZON HOLD 10/06/2006 10/09/2006
Note: Held By: ECOYNE NEED SURVEY/SITE PLAN
ZON COMPLETE 10/19/2006
Note: Released By: ECOYNE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 07/17/2007
STORMWATER REINSPECTION FEE ¤35.00 01/12/2007
ARC POOL/SCREEN REVIEW ¤50.00 10/20/2006
ELECTRIC FEE ¤54.60 10/20/2006
PERMIT FEE ¤246.00 10/20/2006
Fees Total Due: ¤0.00 Total Paid: ¤425.60