I want to search for...
Permit #2006100357
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-00810-0080 |
| CONDITIONED SPACE: 2685 sqft |
| GARAGE: 490 sqft |
| OPENED PORCH (WITH ROOF) : 334 sqft |
| OPENED PORCH (WITH ROOF) : 66 sqft |
| Total Square Footage: 3575 sqft |
| Block: 00810 |
| Subdivision: - |
| Job Phone: (386)447-4400 |
| Location Address: 2 LINCOLN LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/13/2006 |
| NOC: RECORDED |
| Applicant name: DAVID PAUL CROCKETT |
| Owner: PAUL JOSEPH W & VITALIS B |
|
Address 500 E 56TH STREET BROOKLYN, NY 11203 |
| Lot: 0080 |
| Contracted Stated Job Value: ¤295,000.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
THE WATERSIDE GROUP, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17-B BRELYN PLACE PALM COAST, FL 32137 |
RG0041345 (Exp: 08/31/2010) | (386)447-4400 | (386)447-5800 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
LARRY MILTON HISS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1315 A LPGA BLVD Holly Hill, FL 32117 |
CAC032450 (Exp: 08/31/2018) | (386) 672-8688 | (386)238-8688 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/20/2007 | FINAL APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 08/17/2007 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. JACUZZI ACCESS HOLE TO BE MIN. OF 12" X 12" 2. TAPE / SEAL HOOD HOLE IN KITCHEN FOR FINAL 3. ARC RINGS AT BATH MIRRORS | |||
| UTILITY COMPANY FINAL | 08/09/2007 | APPROVED | TSCHWEERS |
| STORMWATER FINAL INSPECTION | 08/06/2007 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 08/01/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: THIS IS A REINSPECTION regrade & sod where dumpsters were.....remove all trash from around dumpster area | |||
| STORMWATER FINAL INSPECTION | 07/27/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: remove dumpsters, regrade & sod same area , move port o let to driveway.....remove all trash from around dumpster area, & from driveway.....30 sf road damage $340.00 | |||
| UTILITY COMPANY FINAL | 07/18/2007 | APPROVED | TSCHWEERS |
| DRIVEWAY | 06/28/2007 | APPROVED | DRANDALL |
| DRIVEWAY | 06/27/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: cut underlayment at road edge at a 90% not 45% | |||
| INSULATION INSPECTION | 03/27/2007 | APPROVED | MMOORE |
| ALL ROUGH | 03/23/2007 | APPROVED | MMOORE |
| Note: FIREPLACE NOT INSTALLED / NOTIFIED MARK GIBSON THAT IT WAS STOLEN | |||
| LATH /BRICK FLASHING | 03/16/2007 | APPROVED | MMOORE |
| Note: THIS IS A REINSPECTION | |||
| LATH /BRICK FLASHING | 03/13/2007 | Disapproved -FEE REQUIRED | MMOORE |
| Note: 1. 2 LAYERS OF MOISTURE BARRIER REQUIRED UNDER LATH 2. DO NOT STUCCO UNTIL COMPLETED | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 01/16/2007 | APPROVED | MMOORE |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 01/12/2007 | APPROVED | WKINELL |
| Note: 0.75 ft lower than proposed. Still at least 12" higher than crown of road.\\wk | |||
| LINTEL | 12/28/2006 | APPROVED | MMOORE |
| MONOLITHIC SLAB INSPECTION/SLAB | 12/13/2006 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 12/08/2006 | APPROVED | MMOORE |
| FIRST ROUGH PLUMBING INSPECTION | 12/07/2006 | CANCELLED BY APPLICANT | MMOORE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 08/09/2007 | 08/14/2007 |
| Note: Released By: CCOTE Approved for Release. Review by Fred R. REVISION: Remove fireplace. | |||
| SW1 | COMPLETE | 05/18/2007 | 05/18/2007 |
| Note: Released By: LAPTEKAR received revised elevations for the topo survey//site plan ommitted driveway dimensions// | |||
| SW1 | HOLD | 04/04/2007 | 04/04/2007 |
| Note: Held By: KTRAINOR We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations appear to be in NGVD29. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised. | |||
| ZON | COMPLETE | 11/08/2006 | 11/08/2006 |
| Note: Released By: DRAMIREZ | |||
| BLD | COMPLETE | 11/08/2006 | 11/08/2006 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| SW1 | COMPLETE | 10/27/2006 | 10/30/2006 |
| Note: Released By: LAPTEKAR Received new topo with clearly identified benchmark. | |||
| ZON | HOLD | 10/18/2006 | 11/01/2006 |
| Note: Held By: ECOYNE Need plantings all along side of home facing Linet Way | |||
| SW1 | HOLD | 10/24/2006 | |
| Note: Held By: LAPTEKAR The benchmark on the sealed topo survey needs to be clearly labled, please submit 3 sealed topo surveys with the benchmark clearly identified. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 08/21/2007 |
| REINSPECTION FEE | ¤40.00 | 08/21/2007 |
| REVISION | ¤40.00 | 08/21/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 08/21/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 08/21/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 08/21/2007 |
| SW REVISION | ¤40.00 | 08/21/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 11/13/2006 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 11/13/2006 |
| STORM WATER PERMIT FEES | ¤80.00 | 11/13/2006 |
| ADMIN FEE | ¤20.00 | 11/13/2006 |
| ARC HOUSE REVIEW | ¤125.00 | 11/13/2006 |
| BUILDING CODE ADMIN FUND | ¤17.88 | 11/13/2006 |
| ELECTRIC FEE | ¤207.00 | 11/13/2006 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 11/13/2006 |
| MECHANICAL FEE | ¤207.00 | 11/13/2006 |
| PERMIT FEE | ¤1,150.50 | 11/13/2006 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 11/13/2006 |
| PLAN CHECK FEE | ¤118.00 | 11/13/2006 |
| PLUMBING FEE | ¤207.00 | 11/13/2006 |
| RADON FEE | ¤17.88 | 11/13/2006 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,985.48 |