I want to search for...

Permit #2006110057

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-01020-0100
CONDITIONED SPACE: 2057 sqft
GARAGE: 426 sqft
OPENED PORCH (WITH ROOF) : 158 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
Total Square Footage: 2691 sqft
Block: 01020
Subdivision: -
Job Phone: (386) 672-8285
Location Address: 96 EVANS DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/14/2006
NOC: RECORDED
Applicant name: JOSEPH TODD VANACORE
Owner: BEVAN, ROBERT & DONNA

Address

343 NW SHOREVIEW DR

PORT ST LUCIE, FL 34986

Lot: 0100
Contracted Stated Job Value: ¤180,000.00
Job Description: SINGLE FAMILY
Type: CN

Contractor

VANACORE CONSTRUCTION INC.
Status Location Address Mailing Address State License Number Phone
INACTIVE

1451 N US HIGHWAY 1

Ormond Beach, FL 32174

SUITE 13

Ormond Beach, FL 32174

CBC058991 (Exp: 08/31/2024) (386) 672-8285

Sub Contractors

DANIEL R SHEFFIELD
Status Location Address State License Number Phone
INACTIVE

1100 Old Haw Creek Road

Bunnell, FL 32110

EC0003100 (Exp: 08/31/2024) 386-931-4729
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
NORMAN LEE HUGHES
Status Location Address State License Number Phone
CANCEL

6429 Fruit Ave

Bunnell, FL 32110

CFC057334 (Exp: 09/30/2008) (386) 437-2702
GREGORY A HAGEMAN
Status Location Address State License Number Phone
ACTIVE

545 Parque Drive

Ormond Beach, FL 32174

CCC021394 (Exp: 08/31/2026) (386) 672-2821

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 04/12/2007 FINAL APPROVED DROCKWELL
FINAL COMPLETE BUILDING INSPECTION 04/11/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: STILL NEED TO HAVE VACUM BREAKERS ON HOSE BIBS AND ON LAUNDRY TUB FAUCET.
FINAL COMPLETE BUILDING INSPECTION 04/10/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: Wrong roof color installed. Contractor to reroof home. Check shingle installation at this inspection. NEED TO HAVE HOUSE NUMBERS......NEED TO REMOVE ROOF BUNDLES.....NEED TO HAVE REC. IN KITCHEN MIN. OF 24" FROM EDGE.....NEED TO HAVE VACUM BREAKERS ON OUTSIDE WATER VALVE AND ON LAUNDRY TUB FAUCET.
STORMWATER FINAL INSPECTION 04/03/2007 APPROVED - AS NOTED GLALIMA
Note: 40 ' FEET OF ROAD DAMAGE = 420.00
UTILITY COMPANY FINAL 04/02/2007 APPROVED MBACON
DRIVEWAY 03/20/2007 APPROVED GLALIMA
RESIDENTIAL EARLY POWER 03/06/2007 APPROVED LHITES
INSULATION INSPECTION 01/18/2007 APPROVED PGALLMANN
LATH /BRICK FLASHING 01/18/2007 APPROVED PGALLMANN
ALL ROUGH 01/16/2007 APPROVED PGALLMANN
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 01/03/2007 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 12/27/2006 Disapproved -FEE REQUIRED CMINI
Note: NEED TO HAVE TRUSS ENGINEERING PACK ON JOB. THREADED ROD LOOSE AT TRUSS TO4 AT WOOD BEARING WALL AND NUT ON MGT LOOSE ON BLOCK WALL SAME TRUSS. HGT ON TRUSS T24 NEEDS TO HAVE A MINIMUM OF 12" EMBEDMENT OF THREADED ROD. 6X6 POST NOT STRAPPED NEED TO BLOCK FLAT TOP TRUSSES THAT ARE MORE THAN 24". NEED TO BLOCK SEAMS ON ROOF SHEATHING THAT ARE LESS THAN 24" RIPS. NOT READY.
LINTEL 12/14/2006 APPROVED PGALLMANN
TEMPORARY POLE 12/14/2006 APPROVED PGALLMANN
Note: LIBBY - SUSAN - 3:30 -12-14-06
FOUNDATION SURVEY APPROVED BY STORMWATER 12/13/2006 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 12/06/2006 APPROVED PGALLMANN
FIRST ROUGH PLUMBING INSPECTION 12/05/2006 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
FIRST ROUGH PLUMBING INSPECTION 12/04/2006 Disapproved -FEE REQUIRED DROCKWELL
Note: No preasure on sanitary lines,Check water presure guage

Review History

Department Status Date In Date Out
SW1 COMPLETE 11/08/2006 11/08/2006
Note: Released By: LAPTEKAR received revised lot grading
BLD COMPLETE 11/07/2006 11/08/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
SW1 HOLD 11/02/2006 11/06/2006
Note: Held By: LAPTEKAR Proposed lot grading elevations at the rear property line appear too low in relation to the FFE and grades around the house. All lot drainage needs to be directed to the front swale. Also need more proposed elevations to indicate how the rear yard will drain.
ZON COMPLETE 11/02/2006 11/07/2006
Note: Released By: DRAMIREZ

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤420.00 04/13/2007
EARLY POWER INSPECTION ¤40.00 04/13/2007
REINSPECTION FEE ¤40.00 04/13/2007
REINSPECTION FEE ¤40.00 04/13/2007
REINSPECTION FEE ¤40.00 04/13/2007
REINSPECTION FEE ¤40.00 04/13/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 11/14/2006
STORM WATER PERMIT FEES ¤80.00 11/14/2006
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 11/14/2006
ADMIN FEE ¤20.00 11/14/2006
ARC HOUSE REVIEW ¤125.00 11/14/2006
BUILDING CODE ADMIN FUND ¤13.46 11/14/2006
ELECTRIC FEE ¤149.40 11/14/2006
FIRE IMPACT FEE 4-1-06 ¤179.37 11/14/2006
MECHANICAL FEE ¤149.40 11/14/2006
PERMIT FEE ¤776.10 11/14/2006
PARKS IMPACT FEE 4/1/06 ¤1,159.02 11/14/2006
PLAN CHECK FEE ¤79.60 11/14/2006
PLUMBING FEE ¤149.40 11/14/2006
RADON FEE ¤13.46 11/14/2006
Fees Total Due: ¤0.00 Total Paid: ¤10,746.04