I want to search for...

Permit #2006110429

Permit Details

Status: COED

Parcel Id: 07-11-31-7059-00800-0020
CONDITIONED SPACE: 2090 sqft
GARAGE: 471 sqft
OPENED PORCH (WITH ROOF) : 101 sqft
OPENED PORCH (WITH ROOF) : 67 sqft
Total Square Footage: 2729 sqft
Block: 00800
Subdivision: -
Job Phone: (386) 672-8285
Location Address: 22 SEAGOING TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/07/2007
NOC: RECORDED
Applicant name: JOSEPH TODD VANACORE
Owner: MCPHERSON, LESLEY & PAULINE

Address

582 KIRKBY RD

ELMONT, NY 11003

Lot: 0020
Contracted Stated Job Value: ¤180,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

VANACORE CONSTRUCTION INC.
Status Location Address Mailing Address State License Number Phone
INACTIVE

1451 N US HIGHWAY 1

Ormond Beach, FL 32174

SUITE 13

Ormond Beach, FL 32174

CBC058991 (Exp: 08/31/2024) (386) 672-8285

Sub Contractors

DANIEL R SHEFFIELD
Status Location Address State License Number Phone
INACTIVE

1100 Old Haw Creek Road

Bunnell, FL 32110

EC0003100 (Exp: 08/31/2024) 386-931-4729
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
NORMAN LEE HUGHES
Status Location Address State License Number Phone
CANCEL

6429 Fruit Ave

Bunnell, FL 32110

CFC057334 (Exp: 09/30/2008) (386) 437-2702
GREGORY A HAGEMAN
Status Location Address State License Number Phone
ACTIVE

545 Parque Drive

Ormond Beach, FL 32174

CCC021394 (Exp: 08/31/2026) (386) 672-2821

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 06/07/2007 FINAL APPROVED DROCKWELL
Note: per request of Dave Jones
FINAL COMPLETE BUILDING INSPECTION 06/05/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: A/C COMPRESSOR NOT ANCHORED. NEED VACCUUM BREAKERS AT HOSE BIBS. STRAP LFNC AT A/C. DISCONNECT NEEDS A CONNECTOR.OUTER SHEATHING OF NM CABLE NEEDS TO ETER BOX BY .25IN. LIGHT OVER TUB NEEDS A SHOWER TRIM. TIGHTEN OUTLET AND STRAP NM AT SPA TUB. SMOKE DETECTORS NEED TO BE AT LEAST 4IN FROM EDGE OF WALL. NEED REC WITHIN 24IN OF SINK. SHOCK ARRESTOR AT DISHWASHER. NEEDA ARC SHIELD IN BATHROOM MIRROR.
STORMWATER FINAL INSPECTION 06/01/2007 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION / ROAD DAMAGE 51 ' FEET = 508.00
STORMWATER FINAL INSPECTION 05/31/2007 Disapproved -FEE REQUIRED GLALIMA
Note: THIS IS A REINSPECTION Place sod 1.5 inches down. Place sod at same elevation as surrounding grade, not in a pile.//wk
STORMWATER FINAL INSPECTION 05/24/2007 Disapproved -FEE REQUIRED DRANDALL
Note: 51 sf road damage..$508.00.....place sod in across street adj. property swale [marked].....seed & straw across street adj. property, beyond new sod in swale
UTILITY COMPANY FINAL 05/21/2007 APPROVED MBACON
DRIVEWAY 05/08/2007 Disapproved -FEE REQUIRED GLALIMA
Note: 6''; DOWN 6 '' UNDER FAILED
DRIVEWAY 05/08/2007 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION . READY TO POUR
RESIDENTIAL EARLY POWER 04/17/2007 APPROVED LHITES
Note: CALLED FPL 4/17
RESIDENTIAL EARLY POWER 04/10/2007 Disapproved -FEE REQUIRED LHITES
Note: ALL DEVICES AND FIXTURES INCLUDING A/H AND A/C MUST BE INSTALLED OR WIRES SAFE AND BLANKED OFF
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/09/2007 APPROVED DROCKWELL
Note:
ALL ROUGH 04/09/2007 APPROVED DROCKWELL
Note:
MONOLITHIC SLAB INSPECTION/SLAB 03/28/2007 APPROVED DROCKWELL
Note:
INSULATION INSPECTION 02/09/2007 APPROVED DROCKWELL
Note:
LATH /BRICK FLASHING 02/02/2007 APPROVED DROCKWELL
Note:
ALL ROUGH 01/23/2007 APPROVED - AS NOTED DROCKWELL
Note: Seal duct thru roof
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 01/12/2007 APPROVED - AS NOTED DROCKWELL
Note: Clip truss at entry/Fasten truss at bath wall master
LINTEL 12/21/2006 APPROVED DROCKWELL
FOUNDATION SURVEY APPROVED BY STORMWATER 12/20/2006 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 12/12/2006 APPROVED DROCKWELL
FIRST ROUGH PLUMBING INSPECTION 12/11/2006 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
BLD COMPLETE 03/15/2007 03/20/2007
Note: Released By: CCOTE Approved for Release. REVISION: Increased rear sreened lanai.
ZON COMPLETE 03/14/2007 03/15/2007
Note: Released By: ECOYNE
BLD COMPLETE 11/28/2006 11/28/2006
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
ZON HOLD 11/21/2006 11/27/2006
Note: Held By: DRAMIREZ need a color material sheet
ZON COMPLETE 11/28/2006
Note: Released By: DRAMIREZ color material sheet submitted
SW1 COMPLETE 11/22/2006
Note: Released By: LAPTEKAR

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤508.00 06/07/2007
EARLY POWER INSPECTION ¤40.00 06/07/2007
EARLY POWER INSPECTION ¤40.00 06/07/2007
PERMIT FEE ¤40.00 06/07/2007
REINSPECTION FEE ¤40.00 06/07/2007
REINSPECTION FEE ¤40.00 06/07/2007
REVISION ¤40.00 06/07/2007
STORMWATER REINSPECTION FEE ¤35.00 06/07/2007
STORMWATER REINSPECTION FEE ¤35.00 06/07/2007
STORMWATER REINSPECTION FEE ¤35.00 06/07/2007
STORMWATER REINSPECTION FEE ¤35.00 06/07/2007
STORMWATER REINSPECTION FEE ¤35.00 06/07/2007
SPECIAL INSPECTIONS ¤40.00 06/07/2007
STORM WATER PERMIT FEES ¤80.00 11/29/2006
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 11/29/2006
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 11/29/2006
PARKS IMPACT FEE 4/1/06 ¤1,159.02 11/29/2006
PLAN CHECK FEE ¤81.20 11/29/2006
PLUMBING FEE ¤151.80 11/29/2006
RADON FEE ¤13.65 11/29/2006
FIRE IMPACT FEE 4-1-06 ¤179.37 11/29/2006
MECHANICAL FEE ¤151.80 11/29/2006
PERMIT FEE ¤791.70 11/29/2006
ADMIN FEE ¤20.00 11/29/2006
ARC HOUSE REVIEW ¤125.00 11/29/2006
BUILDING CODE ADMIN FUND ¤13.65 11/29/2006
ELECTRIC FEE ¤151.80 11/29/2006
Fees Total Due: ¤0.00 Total Paid: ¤11,113.82