I want to search for...
Permit #2006110483
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7028-00160-0150 |
| CONDITIONED SPACE: 1234 sqft |
| CONDITIONED SPACE: 1566 sqft |
| GARAGE: 419 sqft |
| OPENED PORCH (WITH ROOF) : 23 sqft |
| Total Square Footage: 3242 sqft |
| Block: 00160 |
| Subdivision: - |
| Location Address: 29 POPE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/24/2007 |
| NOC: Unknown |
| Applicant name: NO CONTRACTOR OF RECORD |
| Owner: QIN YI LIN |
|
Address 91-10 WHITNEY AVENUE ELMHURST, NY 11373 |
| Lot: 0150 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
NO CONTRACTOR OF RECORD
| Status | State License Number |
| CANCEL | CGC1111111 (Exp: 05/20/2016) |
Sub Contractors
RICHARD R EDWARDS
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 1637 Bunnell, FL 32110 |
ER0011603 (Exp: 08/31/2022) | (386) 437-1537 |
RICHARD LEE VONBROCKEN
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1738 STATE AVE HOLLY HILL, FL 32117 |
CAC035516 (Exp: 08/31/2026) | (386)672-1950 | (386)672-1952 |
MARTIN GEORGE LANGILLE
| Status | Location Address | State License Number | Phone |
| CANCEL |
1727 Maryland Ave Ormond Beach, FL 32174 |
CFC026550 (Exp: 08/31/2018) | (386) 673-3233 |
ANTHONY FALLONE
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P.O. BOX 351222 PALM COAST, FL 32137 |
CBC1250596 (Exp: 08/31/2022) | 386-503-0906 | (386)986-1305 |
Inspection History
| Type | Request Date | Result | Inspector |
| PROJECT STATUS INSPECTION | 11/21/2008 | Disapproved - NO FEE | ACOOPER |
| Note: Inspection Resulted at 11/21/2008 1:13:38 PM HOME HAS BEEN LEFT OPEN AND VANDALIZED. ELECTRICAL WIRING IS CUT, GRASS AND WEEDS ARE UNCUT, WINDOWS BROKEN ALL AROUND, SEE PHOTOS. THIS HOME CURRENTLY IS A SAFETY HAZARD DUE TO BROKEN GLASS AND WINDOWS. ART | |||
| ALL ROUGH | 01/04/2008 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 12/17/2007 | Disapproved -FEE REQUIRED | PGALLMANN |
| Note: THIS IS A REINSPECTION MENDING PLATES ABOVE PANEL STILL MISSING,VENT FOR UPSTAIRS WATER CLOSET NOT TO CODE/ ROLLED UP VENT, STILL MISSING NAIL PLATES ON PLUMBING AND ELECTRIC, NEED TO FIRE BLOCK PLUMBING VENT AND WASTE STACKS ON FIRST FLOOR, SEAL FLOOR @ TUB DRAINS, SHOW 5` HEAD PRESSURE ON SECOND FLOOR TEST, SERVICE CABLE FOR 200 AMP SERVICE UNDER SIZED. PAUL GALLMANN..............931-7400 | |||
| ALL ROUGH | 12/11/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: LOOSE GROUND SCREWS IN MANY ELECTRICAL BOXES, MISSING NAIL PLATES MANY LOCATIONS,NEED RECEPTACLE AT UPSTAIRS HALL AND AT JACUZZI TUB, RESTRAP UPSTAIRS RIGHT REAR WINDOW JACK, ALL TOP PLATES THAT HAVE BEEN NOTCHED OVER 60 % MUST HAVE APPROVED MENDING PLATES. | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 05/17/2007 | APPROVED | DROCKWELL |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/17/2007 | APPROVED - AS NOTED | DROCKWELL |
| LINTEL | 04/04/2007 | APPROVED | ACOOPER |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 04/03/2007 | APPROVED - AS NOTED | LAPTEKAR |
| Note: FFE adjusted / advised care in grading on left side | |||
| TEMPORARY POLE | 03/20/2007 | APPROVED | LHITES |
| Note: | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 02/09/2007 | APPROVED | ACOOPER |
| Note: | |||
| FIRST ROUGH PLUMBING INSPECTION | 02/06/2007 | APPROVED | ACOOPER |
| Note: | |||
| LATH /BRICK FLASHING | |||
| INSULATION INSPECTION | |||
| STORMWATER FINAL INSPECTION | |||
| UTILITY COMPANY FINAL | |||
| FINAL COMPLETE BUILDING INSPECTION |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/28/2006 | 01/03/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| ZON | COMPLETE | 12/19/2006 | 12/19/2006 |
| Note: Released By: DRAMIREZ Changes to roof pitch,color material sheet and landscaping schedule was submitted. | |||
| BLD | HOLD | 12/19/2006 | 12/19/2006 |
| Note: Held By: JJOSEPH Please provide the second copy of your revision signed and sealed (3 of 5 and 4 of 5) Provide the new energy form (600A-04R,600B-04R,600C-04R) using the computer Program FLA/RES version 4.5. | |||
| ZON | HOLD | 11/30/2006 | 12/05/2006 |
| Note: Held By: DRAMIREZ Roof pitch has to be over min. 5/12. Plans show a roof pitch of 4/12. Please revise plan to meet the requirements of the LDC code. | |||
| ZON | HOLD | 11/27/2006 | 11/28/2006 |
| Note: Held By: DRAMIREZ Hold for a color material sheet. Need color samples or numbering. Need landscaping plans. Need 5.12 roof pitch - | |||
| ZON | HOLD | 11/29/2006 | |
| Note: Held By: ECOYNE for ARC meeting 12/01/06 | |||
| SW1 | COMPLETE | 11/28/2006 | |
| Note: Released By: WKINELL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 01/24/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 01/24/2007 |
| BUILDING CODE ADMIN FUND | ¤16.21 | 01/24/2007 |
| ELECTRIC FEE | ¤184.80 | 01/24/2007 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 01/24/2007 |
| MECHANICAL FEE | ¤184.80 | 01/24/2007 |
| PERMIT FEE | ¤1,006.20 | 01/24/2007 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 01/24/2007 |
| PLAN CHECK FEE | ¤103.20 | 01/24/2007 |
| PLUMBING FEE | ¤184.80 | 01/24/2007 |
| RADON FEE | ¤16.21 | 01/24/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 01/24/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/24/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 01/24/2007 |
| REINSPECTION FEE | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| RENEW PERMIT FEES | ¤40.00 | |
| Fees | Total Due: ¤120.00 | Total Paid: ¤10,491.44 |