Permit #2006110484
Permit Details
Status: COED
| Parcel Id: 18-11-31-4961-00000-0010 |
| Block: 00000 |
| Subdivision: 1156 - PALM HARBOR COM. CENTER II |
| Job Phone: (386) 445-5239 |
| Location Address: 7 OLD KINGS RD N |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 03/12/2007 |
| NOC: RECORDED |
| Applicant name: KEITH M PARKER |
| Owner: IRT PROPERTY COMPANY % TREASURY DEPARTMENT |
|
Address 1600 NE MIAMI GARDENS DR NORTH MIAMI BEACH, FL 33179 |
|
Address EQUITY ONE INC NORTH MIAMI BEACH, FL 33179 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤6,000.00 |
| Job Description: UNIT 8 - INTERIOR BUILDOUT - VIP NAILS AT KING PLAZA |
| Type: CN |
Contractor
DILLARD CONSTRUCTION LLC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 355007 PALM COAST, FL 32137 |
CGC1510399 (Exp: 09/30/2010) | 386-864-1320 | (386)986-3054 |
Sub Contractors
HAROLD C WINTZ
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1613 LAKE DRIVE DELAND, FL 32724 |
EC13001593 (Exp: 09/30/2008) | (386)931-4431 | (386)437-9178 |
MARTIN JOHN EVANS
| Status | Location Address | State License Number |
| ACTIVE |
14 FORT CAROLINE CT BUNNELL, FL 32110 |
CFC057676 (Exp: 08/31/2026) |
JESUS AMORO
| Status | Location Address | State License Number | Phone |
| CANCEL |
8327 GOLDEN CHICKASAW CIR ORLAND, FL 32825 |
CAC1814250 (Exp: 09/30/2008) | (407)766-2207 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 07/18/2007 | FINAL APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 07/17/2007 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: requested by contractor please call contractor 931-5018 MISSING THREE RECEPTACLES. USE HARD PIPE ON DRYER EXHAUST. | |||
| FIRE FINAL | 07/16/2007 | APPROVED | JPATTEE |
| Note: THIS IS A REINSPECTION | |||
| H.V.A.C. ROUGH | 07/16/2007 | APPROVED | JLEVRAULT |
| SECOND ROUGH PLUMBING INSPECTION | 07/12/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: NEED ACCESS FOR ALL STUDOR VENTS IN WALL AND ID | |||
| FIRE FINAL | 07/12/2007 | Disapproved - NO FEE | JPATTEE |
| Note: Replace (2) painted FS heads and covers certify fire extinguisher | |||
| UTILITY COMMERCIAL FINAL | 07/10/2007 | APPROVED | KKING |
| FRAMING | 05/31/2007 | APPROVED | JLEVRAULT |
| Note: | |||
| H.V.A.C. ROUGH | 05/30/2007 | APPROVED - AS NOTED | JLEVRAULT |
| Note: called by Antonio Look at exhaust system as well. ABOVE CEILING HVAC | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 05/17/2007 | APPROVED | JLEVRAULT |
| Note: SQUEDULE PER MARK | |||
| FIRST ROUGH PLUMBING INSPECTION | 05/15/2007 | APPROVED - AS NOTED | JGIBSON |
| Note: ALL UNDER GROUND PLUMBING IS OK MUST FILE FOR REVISION FOR RELOCATING ADA LOCATION AND USE OF AUTO VENTS IN LIEU OF VENTS THRU ROOF | |||
| 2ND ROUGH ELECTRICAL | 05/01/2007 | APPROVED | LHITES |
| Note: CALLED BY OWNER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/16/2007 | 05/17/2007 |
| Note: Released By: CCOTE Approved for Release per plan notes. REVISION: Existing plans indicated bathroom as existing Handicap Bathroom however bathroom was being reconfigured as part of this renovation. Due to this the bathroom must fully comply with ADA requirements. Plumbing changes. | |||
| BLD | COMPLETE | 02/26/2007 | 03/01/2007 |
| Note: Released By: CCOTE Approved for Release. | |||
| BLD | HOLD | 12/21/2006 | 01/08/2007 |
| Note: Held By: CCOTE CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2006110484 (VIP Nails) 1/08/2007 The following items must be submitted/clarified in order to complete the Building Permit Application plan review. 1. Provide mechanical layout plan showing location of existing supply diffusers, return diffusers and exhaust diffusers. Indicate which items are new and provide sizes of all new ductwork. Indicate all cfm for each diffuser. 2. Provide mechanical system calculation showing compliance with Florida Mechanical Code Section 403.1. 3. Sheet AR1: There is a detail mark to 13/A9.1f however this detail could not be found. Either provide detail or revise/remove detail mark. 4. Provide energy calculation package showing compliance based on mechanical system modifications. 5. Indicate location of intake and exhaust openings to show compliance of 10-foot separation per Florida Mechanical Code Section 401.5.1 and exhaust openings shall not be directed onto walkways per Section 401.5.2. 6. Provide information for cable noted on radius section detail. Indicate cable type, thickness and method of attachment to blocking and to existing structure. In addition the existing structure must be analyzed for this additional load; if the structure can withstand this load a note shall be added to the drawings indicating this. Also provide length of redhead to be used at the base of the column. 7. Provide minimum clear height below radius ceiling and floor level. 8. If the raised floor area is to contain a function such as a cashier then a ramp is required to access this area. In addition, this raised area must have at least a 4" change in elevation per Florida Building Code Section 1009.3. A 3'-0" clear path around this raised floor area must be maintained. 9. Remove all references to the Florida Residential Code. Indicate the proper code references a. 2004 Florida Building Code, Building. b. 2004 Florida Building Code, Mechanical. c. 2004 Florida Building Code, Plumbing. 10. Provide electrical load calculation and panel schedule. 11. Indicate electric circuits on plan. 12. Provide mechanical subcontractor and license information. 13. Provide plumbing subcontractor and license information. 14. Provide electrical subcontractor and license information. 15. Provide UL Assembly Number and detail for new penetrations of existing fire rated walls. 16. Provide information for venting of dryer. ------------------------------------------------- Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us ------------------------------------------------- | |||
| UD1 | COMPLETE | 12/14/2006 | 12/21/2006 |
| Note: Released By: CJOHNSON | |||
| FI1 | COMPLETE | 12/11/2006 | 12/20/2006 |
| Note: Released By: JPATTEE | |||
| DSD | COMPLETE | 12/04/2006 | 12/11/2006 |
| Note: Released By: DCHAUDOIN |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADDITIONAL FEE | ¤40.00 | 09/26/2007 |
| ADDITIONAL FEE | ¤40.00 | 09/26/2007 |
| ADDITIONAL FEE | ¤40.00 | 09/26/2007 |
| REINSPECTION FEE | ¤40.00 | 09/26/2007 |
| REVISION | ¤40.00 | 09/26/2007 |
| ADMIN FEE | ¤20.00 | 03/12/2007 |
| ELECTRIC FEE | ¤33.60 | 03/12/2007 |
| FIRE PLANS REVIEW | ¤25.00 | 03/12/2007 |
| MECHANICAL FEE | ¤33.60 | 03/12/2007 |
| PERMIT FEE | ¤50.00 | 03/12/2007 |
| PLAN CHECK FEE | ¤100.00 | 03/12/2007 |
| PLUMBING FEE | ¤33.60 | 03/12/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤495.80 |