Status: COED

Parcel Id: 18-11-31-4961-00000-0010
Block: 00000
Subdivision: 1156 - PALM HARBOR COM. CENTER II
Job Phone: (386) 445-5239
Location Address: 7 OLD KINGS RD N
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 03/12/2007
NOC: RECORDED
Applicant name: KEITH M PARKER
Owner: IRT PROPERTY COMPANY % TREASURY DEPARTMENT

Address

1600 NE MIAMI GARDENS DR

NORTH MIAMI BEACH, FL 33179

Address

EQUITY ONE INC

NORTH MIAMI BEACH, FL 33179

Lot: 0010
Contracted Stated Job Value: ¤6,000.00
Job Description: UNIT 8 - INTERIOR BUILDOUT - VIP NAILS AT KING PLAZA
Type: CN

Contractor

DILLARD CONSTRUCTION LLC.
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 355007

PALM COAST, FL 32137

CGC1510399 (Exp: 09/30/2010) 386-864-1320 (386)986-3054

Sub Contractors

HAROLD C WINTZ
Status Location Address State License Number Phone Fax
CANCEL

1613 LAKE DRIVE

DELAND, FL 32724

EC13001593 (Exp: 09/30/2008) (386)931-4431 (386)437-9178
MARTIN JOHN EVANS
Status Location Address State License Number
ACTIVE

14 FORT CAROLINE CT

BUNNELL, FL 32110

CFC057676 (Exp: 08/31/2026)
JESUS AMORO
Status Location Address State License Number Phone
CANCEL

8327 GOLDEN CHICKASAW CIR

ORLAND, FL 32825

CAC1814250 (Exp: 09/30/2008) (407)766-2207

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 07/18/2007 FINAL APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 07/17/2007 Disapproved -FEE REQUIRED JLEVRAULT
Note: requested by contractor please call contractor 931-5018 MISSING THREE RECEPTACLES. USE HARD PIPE ON DRYER EXHAUST.
FIRE FINAL 07/16/2007 APPROVED JPATTEE
Note: THIS IS A REINSPECTION
H.V.A.C. ROUGH 07/16/2007 APPROVED JLEVRAULT
SECOND ROUGH PLUMBING INSPECTION 07/12/2007 APPROVED - AS NOTED JGIBSON
Note: NEED ACCESS FOR ALL STUDOR VENTS IN WALL AND ID
FIRE FINAL 07/12/2007 Disapproved - NO FEE JPATTEE
Note: Replace (2) painted FS heads and covers certify fire extinguisher
UTILITY COMMERCIAL FINAL 07/10/2007 APPROVED KKING
FRAMING 05/31/2007 APPROVED JLEVRAULT
Note:
H.V.A.C. ROUGH 05/30/2007 APPROVED - AS NOTED JLEVRAULT
Note: called by Antonio Look at exhaust system as well. ABOVE CEILING HVAC
MONOLITHIC SLAB INSPECTION/SLAB 05/17/2007 APPROVED JLEVRAULT
Note: SQUEDULE PER MARK
FIRST ROUGH PLUMBING INSPECTION 05/15/2007 APPROVED - AS NOTED JGIBSON
Note: ALL UNDER GROUND PLUMBING IS OK MUST FILE FOR REVISION FOR RELOCATING ADA LOCATION AND USE OF AUTO VENTS IN LIEU OF VENTS THRU ROOF
2ND ROUGH ELECTRICAL 05/01/2007 APPROVED LHITES
Note: CALLED BY OWNER

Review History

Department Status Date In Date Out
BLD COMPLETE 05/16/2007 05/17/2007
Note: Released By: CCOTE Approved for Release per plan notes. REVISION: Existing plans indicated bathroom as existing Handicap Bathroom however bathroom was being reconfigured as part of this renovation. Due to this the bathroom must fully comply with ADA requirements. Plumbing changes.
BLD COMPLETE 02/26/2007 03/01/2007
Note: Released By: CCOTE Approved for Release.
BLD HOLD 12/21/2006 01/08/2007
Note: Held By: CCOTE CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2006110484 (VIP Nails) 1/08/2007 The following items must be submitted/clarified in order to complete the Building Permit Application plan review. 1. Provide mechanical layout plan showing location of existing supply diffusers, return diffusers and exhaust diffusers. Indicate which items are new and provide sizes of all new ductwork. Indicate all cfm for each diffuser. 2. Provide mechanical system calculation showing compliance with Florida Mechanical Code Section 403.1. 3. Sheet AR1: There is a detail mark to 13/A9.1f however this detail could not be found. Either provide detail or revise/remove detail mark. 4. Provide energy calculation package showing compliance based on mechanical system modifications. 5. Indicate location of intake and exhaust openings to show compliance of 10-foot separation per Florida Mechanical Code Section 401.5.1 and exhaust openings shall not be directed onto walkways per Section 401.5.2. 6. Provide information for cable noted on radius section detail. Indicate cable type, thickness and method of attachment to blocking and to existing structure. In addition the existing structure must be analyzed for this additional load; if the structure can withstand this load a note shall be added to the drawings indicating this. Also provide length of redhead to be used at the base of the column. 7. Provide minimum clear height below radius ceiling and floor level. 8. If the raised floor area is to contain a function such as a cashier then a ramp is required to access this area. In addition, this raised area must have at least a 4" change in elevation per Florida Building Code Section 1009.3. A 3'-0" clear path around this raised floor area must be maintained. 9. Remove all references to the Florida Residential Code. Indicate the proper code references a. 2004 Florida Building Code, Building. b. 2004 Florida Building Code, Mechanical. c. 2004 Florida Building Code, Plumbing. 10. Provide electrical load calculation and panel schedule. 11. Indicate electric circuits on plan. 12. Provide mechanical subcontractor and license information. 13. Provide plumbing subcontractor and license information. 14. Provide electrical subcontractor and license information. 15. Provide UL Assembly Number and detail for new penetrations of existing fire rated walls. 16. Provide information for venting of dryer. ------------------------------------------------- Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us -------------------------------------------------
UD1 COMPLETE 12/14/2006 12/21/2006
Note: Released By: CJOHNSON
FI1 COMPLETE 12/11/2006 12/20/2006
Note: Released By: JPATTEE
DSD COMPLETE 12/04/2006 12/11/2006
Note: Released By: DCHAUDOIN

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADDITIONAL FEE ¤40.00 09/26/2007
ADDITIONAL FEE ¤40.00 09/26/2007
ADDITIONAL FEE ¤40.00 09/26/2007
REINSPECTION FEE ¤40.00 09/26/2007
REVISION ¤40.00 09/26/2007
ADMIN FEE ¤20.00 03/12/2007
ELECTRIC FEE ¤33.60 03/12/2007
FIRE PLANS REVIEW ¤25.00 03/12/2007
MECHANICAL FEE ¤33.60 03/12/2007
PERMIT FEE ¤50.00 03/12/2007
PLAN CHECK FEE ¤100.00 03/12/2007
PLUMBING FEE ¤33.60 03/12/2007
Fees Total Due: ¤0.00 Total Paid: ¤495.80