I want to search for...

Permit #2006120151

Permit Details

Status: COED

Parcel Id: 22-11-31-5914-00000-0260
CONDITIONED SPACE: 3676 sqft
GARAGE: 597 sqft
OPENED PORCH (WITH ROOF) : 241 sqft
OPENED PORCH (WITH ROOF) : 48 sqft
OPENED PORCH (WITH ROOF) : 243 sqft
Total Square Footage: 4805 sqft
Subdivision: 2068 - Village G-2 at Grand Haven
Job Phone: (732)610-6681
Location Address: 82 RIVER TRAIL DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/08/2007
NOC: RECORDED
Applicant name: WILLIAM VALENTINE GROFF
Owner: R.F.P. ASSOCIATES LLC

Address

NEW JERSEY LIMITED LIABILITY CO.

LAKEWOOD, NJ 08701

Address

1980 SWARTHMORE AVENUE

LAKEWOOD, NJ 08701

Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

COUNTRY CLUB HOMES OF FLORIDA, INC.
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

4440 N. Oceanshore Blvd

Palm Coast, FL 32137

SUITE 101

Palm Coast, FL 32137

CRC043737 (Exp: 08/31/2012) (386) 445-4747 (386)445-5955

Sub Contractors

STEVEN DUANE DENSLOW
Status Location Address State License Number Phone Fax
CANCEL

400 N. US # 1

Ormond Beach, FL 32174

EC0001678 (Exp: 08/31/2012) (386) 672-8494 (386)673-7856
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
GARY S WELBORN
Status Location Address State License Number Phone Fax
CANCEL

1709 North Nova Road

Holly Hill, FL 32117

CFC037140 (Exp: 08/31/2018) (386) 257-1172 (386)252-5979
WAYNE STEED
Status Location Address State License Number Phone
CANCEL

318 N. PINE AVENUE

IVERNESS, FL 34450

CCC058299 (Exp: 08/31/2010) (352)637-2422

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 11/08/2007 FINAL APPROVED JGIBSON
Note: Updated Energy Calc to be submitted before CO issued. AC units are 14.2 SEER.
STORMWATER FINAL INSPECTION 11/07/2007 APPROVED DRANDALL
UTILITY COMPANY FINAL 11/02/2007 APPROVED TSCHWEERS
Note: Gravity ok.
RESIDENTIAL EARLY POWER 07/31/2007 APPROVED LHITES
Note: callled by contractor
INSULATION INSPECTION 04/23/2007 APPROVED ACOOPER
Note:
GAS ROUGH 04/23/2007 APPROVED ACOOPER
Note:
INSULATION INSPECTION 04/20/2007 Disapproved -FEE REQUIRED RMARVEL
Note: MISSING FIRE CAULK IN MULTIPLE LOCATIONS. ALSO USED WRONG FIRE FOAM UPSTAIRS. NEEDS TO BE RATED FOR FIRE.
LATH /BRICK FLASHING 04/19/2007 APPROVED RMARVEL
Note:
LATH /BRICK FLASHING 04/18/2007 Disapproved -FEE REQUIRED RMARVEL
Note: MISSING LATH ON BACK OF HOUSE.
ALL ROUGH 04/17/2007 APPROVED - AS NOTED JMCGOWEN
Note: NEED TO ADD NAIL PLATES WHERE NEEDED.....CHECK FOR SCREWS IN ARCH WINDOWS....TIGHTEN THREADED RODS..FIRE BLOCK....
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/13/2007 APPROVED RMARVEL
Note:
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 03/21/2007 Disapproved -FEE REQUIRED JGIBSON
Note: LETTER OF REPAIR ON BOND BEAM ON LANI @ MASTER BEDROOM SLIDER, VALLEY STRAPS NOT DONE, JACK NOT STRAPED HJ07, VALLEY FLASHING NOT COMPLETED, EXSPOSE ALL COVERED OPENING 2 ENTRY FOR INSPECTION TO CMU
LINTEL 02/14/2007 APPROVED JGIBSON
FLOOD ZONE 'A' ELEVATION CERTIFICATE APPROVAL 02/13/2007 APPROVED CBENTLEY
MONOLITHIC SLAB INSPECTION/SLAB 02/05/2007 APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB INSPECTION/SLAB 02/02/2007 CANCELLED BY APPLICANT JGIBSON
FIRST ROUGH PLUMBING INSPECTION 01/31/2007 APPROVED JMCGOWEN
TEMPORARY POLE 01/31/2007 APPROVED LHITES
Note: release of meter for temp pole i called susan at 9:30 a.m.

Review History

Department Status Date In Date Out
BLD COMPLETE 11/08/2007 11/08/2007
Note: Released By: CCOTE Approved for Release. REVISION: Revised energy calcs.
PLFM COMPLETE 01/03/2007 01/05/2007
Note: Released By: CBENTLEY
BLD COMPLETE 12/29/2006 01/03/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
BLD HOLD 12/21/2006 12/21/2006
Note: Held By: JJOSEPH Provide an HVAC sizing calculation performed on the building as required by Florida Building Code Section 13-607.1.ABC.1. ( At least version 4.0 or manual J 8th edition). Note: Since December 8, 2006, the Energy form 600A-2004 is no longer acceptable . According to the 2006 supplement Florida Building Code, The new energy form 600A-04Ror 600B-04R or 600C-04R must be provided using the Computer program FLA/RES-04 version 4.5 .
ZON COMPLETE 12/19/2006 12/19/2006
Note: Released By: ECOYNE walkway is to be removed - received letter from contractor giving 60 days (Feb 12, 2007) ecoyne
URB COMPLETE 12/19/2006 12/20/2006
Note: Released By: JBEAUDET to check barricades in place for existing trees per Carol Hamilton 12/19/06
ZON HOLD 12/07/2006 12/11/2006
Note: Held By: ECOYNE Need setbacks on survey (unclear) 4' concrete walkway ? Concrete monument?
SW1 COMPLETE 12/20/2006
Note: Released By: LAPTEKAR Flood Zone AE and X...foundation inspection removed..elevation certificate req.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 11/09/2007
REINSPECTION FEE ¤40.00 11/09/2007
REINSPECTION FEE ¤40.00 11/09/2007
REINSPECTION FEE ¤40.00 11/09/2007
REVISION ¤40.00 11/09/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 01/08/2007
STORM WATER PERMIT FEES ¤80.00 01/08/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 01/08/2007
ADMIN FEE ¤20.00 01/08/2007
BUILDING CODE ADMIN FUND ¤24.03 01/08/2007
ELECTRIC FEE ¤240.60 01/08/2007
FIRE IMPACT FEE 4-1-06 ¤179.37 01/08/2007
MECHANICAL FEE ¤240.60 01/08/2007
PERMIT FEE ¤1,368.90 01/08/2007
PARKS IMPACT FEE 4/1/06 ¤1,159.02 01/08/2007
PLAN CHECK FEE ¤140.40 01/08/2007
PLUMBING FEE ¤240.60 01/08/2007
RADON FEE ¤24.03 01/08/2007
Fees Total Due: ¤0.00 Total Paid: ¤11,149.38