Permit #2006120155

Permit Details

Status: COED

Parcel Id: 06-12-31-5815-00000-0200
COMMERCIAL SQUARE FOOTAGE: 6257 sqft
Total Square Footage: 6257 sqft
Block: 00000
Subdivision: 2118 - Town Center Phase I
Job Phone: (904)260-2900
Location Address: 21 HOSPITAL DR
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 02/06/2007
NOC: RECORDED
Applicant name: RONALD H FOSTER
Owner: PALM COAST MEDICAL SPECIALISTS LTD

Address

21 HOSPITAL DR STE 200

PALM COAST, 0

Lot: 0200
Contracted Stated Job Value: ¤544,838.00
Job Description: INTERIOR BUILD-OUT SUITE 110 "ALTER ORTHOPAEDICS"
Type: CN

Contractor

STELLAR GROUP INC
Status Location Address State License Number Phone
INACTIVE

2900 HARTLEY ROAD

JACKSONVILLE, FL 32257

CGC052029 (Exp: 08/31/2024) 904-899-9214

Sub Contractors

RONALD A AUTREY
Status Location Address State License Number Phone
CANCEL

PO Box 1799

Jacksonville, Fl., 32201

ECOOOO388 (Exp: 08/31/2018) (904) 388-8000
ERIC TIMOTHY HOLCOMB
Status Location Address State License Number Phone Fax
CANCEL

101 MUNDY MEMORIAL

MT JULIET, TN 37122

CMC1249492 (Exp: 09/30/2008) (800)222-1819 (615)773-8108
GARY S WELBORN
Status Location Address State License Number Phone Fax
CANCEL

1709 North Nova Road

Holly Hill, FL 32117

CFC037140 (Exp: 08/31/2018) (386) 257-1172 (386)252-5979
ANTHONY JAMES PARETE
Status Location Address State License Number Phone Fax
INACTIVE

6900 PHILLIPS INDUSTRIAL BLVD.

JACKSONVILLE, FL 32256

CCC044057 (Exp: 08/31/2026) (904)880-6005 (904)880-3377
WILLIAM W GAY
Status Location Address State License Number Phone Fax
DECEASED

524 STOCKTON STREET

JACKSONVILLE, FL 32204

CMC008140 (Exp: 08/31/2020) (904)388-2696 904-394-7944
JOHN W BARBER JR
Status Location Address State License Number Phone Fax
INACTIVE

1514 BERNITA STREET

JACKSONVILLE, FL 32211

CCC057141 (Exp: 08/31/2020) (904)744-4067 (904)744-4209

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 04/14/2008 FINAL APPROVED JLEVRAULT
FINAL COMPLETE BUILDING INSPECTION 04/08/2008 FINAL APPROVED JLEVRAULT
Note: requested by contractor
FIRE FINAL 04/04/2008 APPROVED JPATTEE
ELECTRICAL FINAL 03/28/2008 APPROVED RMARVEL
PLUMBING FINAL 03/19/2008 FINAL APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
PLUMBING FINAL 03/18/2008 Disapproved - NO FEE PGALLMANN
Note: THIS IS A REINSPECTION
PLUMBING FINAL 03/14/2008 Disapproved -FEE REQUIRED PGALLMANN
Note: NO HOT WATER.
H.V.A.C. FINAL 03/14/2008 APPROVED JLEVRAULT
ABOVE CEILING 10/17/2007 APPROVED JMCGOWEN
COMMERCIAL POWER INSPECTION 09/12/2007 APPROVED LHITES
Note: UNIT 110 PLACED CITY STICKER FOR POWER APPROVAL ON METER CAN NO LIGHTING OR RECEPTICALS ARE GOING TO BE ENERGIZED UNTIL INSTALLED AND INSPECTED. SERVICE PANELS WILL BE LOCKED UNLESS QUALIFIED ELECTRICIAN IS WORKING ON CIRCUITS OF SAID PANELS
FIREWALL FINAL INSPECTION 07/05/2007 APPROVED JLEWIS
FIREWALL INSPECTION 06/05/2007 APPROVED JPATTEE
H.V.A.C. ROUGH 06/05/2007 Disapproved - NO FEE JLEVRAULT
Note: THIS WAS INSPECTED AND APPROVED YESTERDAY.
H.V.A.C. ROUGH 06/04/2007 APPROVED JLEVRAULT
Note:
H.V.A.C. ROUGH 06/01/2007 APPROVED - AS NOTED JLEVRAULT
Note: DRYER VENT.
INSULATION INSPECTION 05/31/2007 APPROVED JHINDMAN
H.V.A.C. ROUGH 05/21/2007 Disapproved - NO FEE JMCGOWEN
Note: COURTESY INSPECTION FOR HVAC,NO INSPECTION MADE.
FRAMING 05/21/2007 CANCELLED BY APPLICANT JHINDMAN
2ND ROUGH ELECTRICAL 05/18/2007 APPROVED LHITES
Note: WALLS ONLY UNIT 110
FRAMING 05/16/2007 APPROVED - AS NOTED JHINDMAN
Note: walls only
2ND ROUGH ELECTRICAL 05/15/2007 Disapproved - NO FEE LHITES
Note: OWNER IS MAKING CHANGES AND I'M UNABLE TO COMPLETE INSPECTION
FIRE SPRINKLER 2ND ROUGH HYDROSTATIC PRESSURE TEST 05/15/2007 APPROVED JPATTEE
SECOND ROUGH PLUMBING INSPECTION 05/10/2007 APPROVED - AS NOTED JGIBSON
Note: partial inspection on walls only.

Review History

Department Status Date In Date Out
BLD COMPLETE 03/27/2008 03/27/2008
Note: Released By: FREODICA Revision: paper towel dispenser fire extinguisher cabinet in waiting area room in conflict with seating arrangement and wall framing.
ELEC COMPLETE 03/25/2008 03/25/2008
Note: Released By: SKNOPF Approved for Release. Revision: Various Electrical changes (see Electrical Comments 3-17-2008). Released by L.W.
ELEC HOLD 03/11/2008 03/17/2008
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Permit #2006120155 (Suite 110 Alter Orthopedics @ 21 Hospital Dr) 3/17/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E001-110: a. The following circuits have undersized loads in the panel schedule: 51, 55, 57, 59, 60, 61, 63, and 73. Please review and revise. b. The following circuits show no load for their identification in the panel schedule: 74, 76, 78, 80, and 82. Please review and revise. c. Please provide nameplate loads for the following equipment (circuit) for load calculation verification: X-ray viewing (1), X-ray machine (3), copier (5), refrigerator (7), washer (11), dryer (15:17), coffee maker (41), x-ray feeder (79:81:83), X-ray PIR (80). d. The load shown for circuit 23:25:27 is undersized. Please review and revise. e. Provide the nameplate load for the following equipment: CU-1-1-A, CU-1-1-B, AHU-1-1-A, AHU-1-1-B. Mechanical schedule has insufficient electrical data for load calculation verification. f. Revise Load Calculation to conform to NEC 220 using actual lighting, receptacle, equipment, HVAC and largest motor loads. g. It appears the Demand Load may be significantly larger than both the Suite feeder and the Meter/Circuit Breaker size given on the Riser. Please review and revise. 2. E101-110: a. Waiting 1100 shows conflicting circuit identification for fixtures on switchlegs 'a' and 'c'. Please review and revise. 3. E102-110: a. CU-1-1-A is not within 25' of a receptacle for servicing equipment per NEC 210.63. Please review and revise. b. VAV-1-1-A1 is shown in Mechanical schedule as 12KW @ 208V 3ph yielding 33A. The local disconnect for this equipment shows it to be fused at 20A. Please review and revise. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
FI1 COMPLETE 01/23/2007 01/25/2007
Note: Released By: JPATTEE One(1) set sent to FD on 1/8/2007.
BLD COMPLETE 01/16/2007 02/01/2007
Note: Released By: CCOTE Approved for Release. Review by Fred R.
BLD HOLD 12/14/2006 12/18/2006
Note: Held By: FREODICA 1. Dwg. Shts. A101- 110 and G101-110: a. Revise wall type between suites 110 and 120 to match with dwg. sht. A102 of shell building. Also, indicate the door to be fire rated. 2. Dwg. Sht. M101-110: a. The roof access was shown blocked by 8" diameter toilet exhaust duct. Provide clear access. 3. Dwg. Sht. P001-130: a. Remove this drawing from the drawing set as this drawing belong to suite 130. 4. Dwg. Sht. P101-110: a. Condensate drains from AHU-1-1-A, AHU-1-1-B, RTU-1-1-A and RTU-1-1-B were shown connected to existing drain system but those existing drains were not referenced and can not be found. 5. Dwg. Sht. E102-110: a. Roof plan note 2 says coordinate exact location of mechanical units with mechanical plan. Both plans (mechanical & electrical) are not coordinated. Revise accordingly. Show only those equipments intended to be on the roof plan. b. Electrical supply for exhaust fans on roof are missing. c. Provide additional GFCI receptacle outlet for servicing equipments on roof to comply with NEC 2005 Sec 210.63.
DSD COMPLETE 01/30/2007
Note: Released By: DCHAUDOIN
UD1 COMPLETE 01/25/2007
Note: Released By: CJOHNSON

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADDITIONAL FEE ¤40.00 04/04/2008
ADDITIONAL FEE ¤40.00 04/04/2008
REINSPECTION FEE ¤40.00 04/04/2008
REVISION ¤120.00 04/04/2008
REVISION ¤40.00 04/04/2008
ADMIN FEE ¤20.00 02/06/2007
ELECTRIC FEE ¤357.00 02/06/2007
FIRE PLANS REVIEW ¤62.57 02/06/2007
MECHANICAL FEE ¤357.00 02/06/2007
PERMIT FEE ¤3,815.00 02/06/2007
PLAN CHECK FEE ¤626.75 02/06/2007
PLUMBING FEE ¤357.00 02/06/2007
Fees Total Due: ¤0.00 Total Paid: ¤5,875.32