Permit #2006120164

Permit Details

Status: COED

Parcel Id: 06-12-31-5815-00000-0200
COMMERCIAL SQUARE FOOTAGE: 1996 sqft
Total Square Footage: 1996 sqft
Block: 00000
Subdivision: 2118 - Town Center Phase I
Job Phone: (904)260-2900
Location Address: 21 HOSPITAL DR
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 02/06/2007
NOC: RECORDED
Applicant name: RONALD H FOSTER
Owner: PALM COAST MEDICAL SPECIALISTS LTD

Address

21 HOSPITAL DR STE 200

PALM COAST, FL 32164

Lot: 0200
Contracted Stated Job Value: ¤200,788.00
Job Description: BUILD-OUT SUITE 150 "ATLANTIC PODIATRY"
Type: CN

Contractor

STELLAR GROUP INC
Status Location Address State License Number Phone
INACTIVE

2900 HARTLEY ROAD

JACKSONVILLE, FL 32257

CGC052029 (Exp: 08/31/2024) 904-899-9214

Sub Contractors

RONALD A AUTREY
Status Location Address State License Number Phone
CANCEL

PO Box 1799

Jacksonville, Fl., 32201

ECOOOO388 (Exp: 08/31/2018) (904) 388-8000
ERIC TIMOTHY HOLCOMB
Status Location Address State License Number Phone Fax
CANCEL

101 MUNDY MEMORIAL

MT JULIET, TN 37122

CMC1249492 (Exp: 09/30/2008) (800)222-1819 (615)773-8108
GARY S WELBORN
Status Location Address State License Number Phone Fax
CANCEL

1709 North Nova Road

Holly Hill, FL 32117

CFC037140 (Exp: 08/31/2018) (386) 257-1172 (386)252-5979
ANTHONY JAMES PARETE
Status Location Address State License Number Phone Fax
INACTIVE

6900 PHILLIPS INDUSTRIAL BLVD.

JACKSONVILLE, FL 32256

CCC044057 (Exp: 08/31/2026) (904)880-6005 (904)880-3377
JOHN W BARBER JR
Status Location Address State License Number Phone Fax
INACTIVE

1514 BERNITA STREET

JACKSONVILLE, FL 32211

CCC057141 (Exp: 08/31/2020) (904)744-4067 (904)744-4209
WILLIAM W GAY
Status Location Address State License Number Phone Fax
DECEASED

524 STOCKTON STREET

JACKSONVILLE, FL 32204

CMC008140 (Exp: 08/31/2020) (904)388-2696 904-394-7944

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 04/10/2008 FINAL APPROVED LWOODROME
Note: per Larry - 99 permit
FINAL COMPLETE BUILDING INSPECTION 04/08/2008 FINAL APPROVED JLEVRAULT
UTILITY COMMERCIAL FINAL 04/08/2008 APPROVED DSPENCER
FIRE FINAL 04/04/2008 APPROVED JPATTEE
ELECTRICAL FINAL 03/24/2008 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
ELECTRICAL FINAL 03/10/2008 CANCELLED BY APPLICANT LHITES
PLUMBING FINAL 03/10/2008 Disapproved -FEE REQUIRED JGIBSON
Note: EQUIPMENT NOT INSTALLED [PROSSESOR]...........MARK..........931-2912
H.V.A.C. FINAL 03/10/2008 APPROVED JLEVRAULT
ABOVE CEILING 11/14/2007 APPROVED JLEVRAULT
FIREWALL INSPECTION 11/06/2007 APPROVED JPATTEE
FIRE SPRINKLER 1ST ROUGH 10/31/2007 APPROVED JPATTEE
2ND ROUGH ELECTRICAL 10/12/2007 APPROVED LHITES
FIREWALL INSPECTION 09/21/2007 Disapproved -FEE REQUIRED JPATTEE
SECOND ROUGH PLUMBING INSPECTION 08/17/2007 APPROVED JGIBSON
2ND ROUGH ELECTRICAL 08/13/2007 APPROVED RMARVEL
INSULATION INSPECTION 08/09/2007 APPROVED JLEVRAULT
INSULATION INSPECTION 08/08/2007 Disapproved - NO FEE JHINDMAN
Note: CANCELLED BY JOHN
H.V.A.C. ROUGH 08/07/2007 APPROVED JLEVRAULT
FRAMING 08/02/2007 APPROVED JHINDMAN
FIRE SPRINKLER 2ND ROUGH HYDROSTATIC PRESSURE TEST 07/18/2007 APPROVED JPATTEE
Note: THIS IS A REINSPECTION
FIRE SPRINKLER 2ND ROUGH HYDROSTATIC PRESSURE TEST 07/12/2007 CANCELLED BY APPLICANT JPATTEE
FIRE SPRINKLER 1ST ROUGH 07/12/2007 APPROVED JPATTEE

Review History

Department Status Date In Date Out
ELEC COMPLETE 03/20/2008 03/20/2008
Note: Released By: SKNOPF Approved for Release. Revision: Various electrical changes (see electrical comments 3-17-2008). Released by L.W.
ELEC HOLD 03/11/2008 03/17/2008
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Permit #2006120164 (Suite 150 Atlantic Podiatry @ 21 Hospital Dr) 3/17/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E001-150: a. The following circuits in the panel schedule have undersized loads: 3,5,6,7,9,11. Please review and revise. b. The following circuits have no load shown in the panel: 10, 27. Please review and revise. c. Provide the actual nameplate load for the following equipment (circuit): speedclave (15), refrigerator (17), dark room equipment (21), microwave (25), x-ray (35:37). Please review and revise. d. Water Heater (circuit 39:41) in panel schedule is shown as 6KVA. Plumbing schedule shows this equipment as 9KVA. Please review and revise. e. Please provide the nameplate load for the following equipment: AHU-1-5-B, CU-1-5-B, AHU-1-5-A, VAV-1-5-A2, VAV-1-5-A3, BP-1-5-A. Mechanical schedule in incomplete for electrical data. f. Provide Load Calculation to conform to NEC 220 using actual lighting, receptacle, equipment, HVAC and largest motor loads. g. It appears that the Demand load may exceed the circuit breaker size for the feeder to this suite. Please review and revise accordingly. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
FI1 COMPLETE 01/23/2007 01/25/2007
Note: Released By: JPATTEE One(1) set of Plan sent to FD on 1/8/2007.
BLD COMPLETE 01/16/2007 02/01/2007
Note: Released By: CCOTE Approved for Release. Review by Fred R.
BLD HOLD 12/14/2006 01/02/2007
Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2006120164 - Atlantic Podiatry - Suite150 1. Dwg. No. M101-150: a. Return air from waiting room 1500 was missing. b. Roof plan showed two(2) condensing units having the same name designation (CU- 1-5-A and CU-1-5-B). 2. Dwg. No. P101-150: a. Provide information on condensate lines. Indicate what size, material and how are they routed. 3. Dwg. No. P102-150: a. Coordinate layout of hot/cold water supply to sink at nurse station 1513 to match with riser diagram on Dwg. No. P802-150. 4. Dwg. No. E102-150: a. Electrical supply to Exhaust fan EF-1-5-A was missing. Instead, there were exhaust fans for toilets and dark room but none of these were shown on mechanical drawing. Please clarify.
DSD COMPLETE 01/30/2007
Note: Released By: DCHAUDOIN
UD1 COMPLETE 01/25/2007
Note: Released By: CJOHNSON

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADDITIONAL FEE ¤40.00 04/04/2008
ADDITIONAL FEE ¤40.00 04/04/2008
REINSPECTION FEE ¤40.00 04/04/2008
REINSPECTION FEE ¤40.00 04/04/2008
REVISION ¤40.00 04/04/2008
ADMIN FEE ¤20.00 02/06/2007
ELECTRIC FEE ¤150.60 02/06/2007
FIRE PLANS REVIEW ¤25.00 02/06/2007
MECHANICAL FEE ¤150.60 02/06/2007
PERMIT FEE ¤1,407.00 02/06/2007
PLAN CHECK FEE ¤231.15 02/06/2007
PLUMBING FEE ¤150.60 02/06/2007
Fees Total Due: ¤0.00 Total Paid: ¤2,334.95