Permit #2006120165

Permit Details

Status: COED

Parcel Id: 06-12-31-5815-00000-0200
COMMERCIAL SQUARE FOOTAGE: 6291 sqft
Total Square Footage: 6291 sqft
Block: 00000
Subdivision: 2118 - Town Center Phase I
Job Phone: (904)260-2900
Location Address: 21 HOSPITAL DR
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 02/06/2007
NOC: RECORDED
Applicant name: RONALD H FOSTER
Owner: PALM COAST MEDICAL SPECIALISTS LTD

Address

21 HOSPITAL DR STE 200

PALM COAST, FL 32164

Lot: 0020
Contracted Stated Job Value: ¤599,182.00
Job Description: BUILD-OUT SUITE 160 - TOMOKA EYE ASSOCIATES
Type: CN

Contractor

STELLAR GROUP INC
Status Location Address State License Number Phone
INACTIVE

2900 HARTLEY ROAD

JACKSONVILLE, FL 32257

CGC052029 (Exp: 08/31/2024) 904-899-9214

Sub Contractors

RONALD A AUTREY
Status Location Address State License Number Phone
CANCEL

PO Box 1799

Jacksonville, Fl., 32201

ECOOOO388 (Exp: 08/31/2018) (904) 388-8000
ERIC TIMOTHY HOLCOMB
Status Location Address State License Number Phone Fax
CANCEL

101 MUNDY MEMORIAL

MT JULIET, TN 37122

CMC1249492 (Exp: 09/30/2008) (800)222-1819 (615)773-8108
GARY S WELBORN
Status Location Address State License Number Phone Fax
CANCEL

1709 North Nova Road

Holly Hill, FL 32117

CFC037140 (Exp: 08/31/2018) (386) 257-1172 (386)252-5979
ANTHONY JAMES PARETE
Status Location Address State License Number Phone Fax
INACTIVE

6900 PHILLIPS INDUSTRIAL BLVD.

JACKSONVILLE, FL 32256

CCC044057 (Exp: 08/31/2026) (904)880-6005 (904)880-3377
WILLIAM W GAY
Status Location Address State License Number Phone Fax
DECEASED

524 STOCKTON STREET

JACKSONVILLE, FL 32204

CMC008140 (Exp: 08/31/2020) (904)388-2696 904-394-7944
JOHN W BARBER JR
Status Location Address State License Number Phone Fax
INACTIVE

1514 BERNITA STREET

JACKSONVILLE, FL 32211

CCC057141 (Exp: 08/31/2020) (904)744-4067 (904)744-4209

Inspection History

Type Request Date Result Inspector
UTILITY COMMERCIAL FINAL 04/08/2008 APPROVED DSPENCER
FINAL COMPLETE BUILDING INSPECTION 04/08/2008 FINAL APPROVED JLEVRAULT
FIRE FINAL 04/04/2008 APPROVED JPATTEE
ELECTRICAL FINAL 04/02/2008 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
PLUMBING FINAL 03/28/2008 APPROVED - AS NOTED JGIBSON
Note: THIS IS A REINSPECTION NEED DRAIN UNGLOGGED BEFORE BUILDING FINAL.
ELECTRICAL FINAL 03/24/2008 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION NEED REVISIONS WHERE RECEPTACLES ARE ADDED.
PLUMBING FINAL 03/11/2008 Disapproved -FEE REQUIRED JGIBSON
Note: MISSING SINK @ FRONT OF OFFICE...........MARK 931-2912
ELECTRICAL FINAL 03/11/2008 Disapproved -FEE REQUIRED LHITES
Note: REVISED PLANS ARE NOT CORRECT TO THE UNIT. THERE ARE EXTRA OUTLETS AND PANEL POSITION IS NOT ACCORDING TO PLAN
H.V.A.C. FINAL 03/11/2008 APPROVED JLEVRAULT
ABOVE CEILING 11/27/2007 APPROVED JLEVRAULT
ABOVE CEILING 11/26/2007 Disapproved -FEE REQUIRED JLEVRAULT
Note: CEILING NOT READY.
FIREWALL FINAL INSPECTION 11/26/2007 APPROVED JLEWIS
FLOOR OR WALL PENETRATION 11/16/2007 APPROVED JPATTEE
COMMERCIAL POWER INSPECTION 10/23/2007 APPROVED LHITES
2ND ROUGH ELECTRICAL 08/24/2007 APPROVED RMARVEL
SECOND ROUGH PLUMBING INSPECTION 08/17/2007 APPROVED JGIBSON
H.V.A.C. ROUGH 08/14/2007 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
FRAMING 08/10/2007 APPROVED JHINDMAN
H.V.A.C. ROUGH 08/09/2007 CANCELLED BY INSPECTOR JLEVRAULT
Note: THIS IS A REINSPECTION CALLED IN BY MISTAKE.
INSULATION INSPECTION 08/09/2007 APPROVED JLEVRAULT
H.V.A.C. ROUGH 08/08/2007 Disapproved -FEE REQUIRED JLEVRAULT
Note: 1. TWO CONDENSATE PANS ARE TOO SMALL. 2. TRUNK LINE IS SIGNIFICANTLY OUT OF PLANE.
H.V.A.C. ROUGH 08/07/2007 Disapproved - NO FEE JLEVRAULT
Note: CANCELLED BY CONTRACTOR.
FIRE SPRINKLER 2ND ROUGH HYDROSTATIC PRESSURE TEST 07/18/2007 APPROVED JPATTEE
Note: THIS IS A REINSPECTION
FIRE SPRINKLER 1ST ROUGH 07/12/2007 APPROVED JPATTEE
FIRE SPRINKLER 2ND ROUGH HYDROSTATIC PRESSURE TEST 07/12/2007 CANCELLED BY APPLICANT JPATTEE

Review History

Department Status Date In Date Out
ELEC COMPLETE 03/31/2008 04/01/2008
Note: Released By: SKNOPF Approved for Release. REVISION -1600 duplex added ckt #3 -1639 duplex removed -1638 (2) duplex's removed ckt 73, 79 -1640 duplex added ckt #73 -Added undercounter light and switch at Dictation area Corridor 1607 -Added undercounter light and switch at Dictation area Corridor 1616
ELEC COMPLETE 03/20/2008 03/20/2008
Note: Released By: SKNOPF Approved for Release. Revision: Various electrical changes (see Electrical Comments 3-13-2008). Released per L.W.
ELEC HOLD 03/11/2008 03/13/2008
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2006120165 (Suite 160 Tomoka Eye Assoc. @ 21 Hospital Dr) 3/13/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E001-160: a. Identify load (KVA) requirements, or remove, equipment listed in Panel Schedule circuits 61, 63, 65 and 79. b. Was supplemental heat required for AHU's in this suite, and if so, please provide KVA load for Load Calculation verification. c. The following circuits are showing undersized loads. Please review and revise. Panel 160: 5,7,8,9,11,13,15,16,17,18,19,21,22,24,25,26,27,29,36,39. d. Water Heater load in panel schedule should be 9000VA to match P001-160. Please review and revise load, circuit breaker, disconnect and wire size. e. Revise Load Calculations to conform to NEC standards showing actual lighting, receptacle, largest motor, equipment and HVAC per NEC 220. f. Please note that the panel schedule labeling for room identification is not correct for all circuits. 2. E101-160: a. Lighting plan shows (14) type 'A', (12) type 'M', plus (5) type 'UC3' fixtures totaling 2146VA on circuit 8. Maximum allowable load on a 20A lighting circuit is 1920VA per NEC 210.19(A)(1). Please review and revise. b. Clarify switching on plan sheet for Janitor closet 1609. c. Identify ceiling fan load in fixture schedule and add load to respective circuits for rooms 1625, 1636 and 1637. d. Identify fixture load in fixture schedule for Owner-furnished recess fixtures shown in Optical Retail 1602 (quantity 39) for Load Calculation verification. e. Provide wall switch 'd' on plan sheet, and identify circuit for (3) switchleg 'd' type 'M' fixtures shown in Optical Retail 1602. Add load for fixtures in panel schedule. f. Verify switching for undercounter lights in Optical Lab 1603. Switching not shown. 3. E102-160: a. Identify receptacle circuit west wall Dilution Waiting room 1610, and add load into panel schedule. b. Identify receptacle circuit northeast corner Exam 7 room 1614, and add load into panel schedule. c. Identify actual equipment loads (nameplate) for refrigerator circuit 35, microwave circuit 28, and copier circuit 33. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
BLD COMPLETE 12/12/2007 12/13/2007
Note: Released By: FREODICA Rev.- Misc. revisions. See listing on file. Changes are "clouded". Sheets A101/102/201/501/601/602, M101, E001/101/102.
FI1 COMPLETE 01/23/2007 01/25/2007
Note: Released By: JPATTEE one(1) set of plan sent to FD on 1/8/2007.
BLD COMPLETE 01/16/2007 02/01/2007
Note: Released By: CCOTE Approved for Release. Review by Fred R.
BLD HOLD 12/14/2006 01/04/2007
Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2006120165 - Tomoka Eye Associates - Suite160 1. Dwg. No. M001-160: a. VAV-1-8-A5 was indicated on VAV Box Unit Schedule but can not be found on plan. b. BD-1-8-A was shown on plan but not indicated on VAV Box Unit Schedule. 2. Dwg. No. M101-160: a. Return air from Ascan 1631 was missing. b. Location of space sensor for VAV-1-8-B5 was not shown on plan. 3. Dwg. No. P101-160: a. Provide reference information on condensate lines tied to existing system. b. Show on plan AHU's and condensate lines. 4. Dwg. No. P101-160/P801-160: a. Plumbing fixtures for Exam 5 (1618), Exam 12 (1620) and Contact Lens 1601 did not match with sanitary riser diagram. b. Floor drain, FD-1 for handicapped toilet 1646 was missing on sanitary riser diagram. 5. Dwg. No. E102-160: a. Electrical supply to Exhaust fan EF-1-8-A was missing. Instead, there were exhaust fans for all toilets but none of these were shown on mechanical drawing. Please clarify. b. Location of water heater on janitor's closet 1609 did not match with plumbing, mechanical and architectural drawings.
DSD COMPLETE 01/30/2007
Note: Released By: DCHAUDOIN
UD1 COMPLETE 01/25/2007
Note: Released By: CJOHNSON
BLD COMPLETE 03/27/2008
Note: Released By: JJOSEPH Revision: paper towel dispensers pass through cabinet at reception 1645 desk area deleted pass through from waiting room to reception is 1-10' planter in waiting area room 1600 has been removed.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADDITIONAL FEE ¤40.00 04/04/2008
ADDITIONAL FEE ¤40.00 04/04/2008
REINSPECTION FEE ¤40.00 04/04/2008
REINSPECTION FEE ¤40.00 04/04/2008
REINSPECTION FEE ¤40.00 04/04/2008
REINSPECTION FEE ¤40.00 04/04/2008
REINSPECTION FEE ¤40.00 04/04/2008
REVISION ¤40.00 04/04/2008
REVISION ¤80.00 04/04/2008
REVISION ¤80.00 04/04/2008
ADMIN FEE ¤20.00 02/06/2007
ELECTRIC FEE ¤390.00 02/06/2007
FIRE PLANS REVIEW ¤62.91 02/06/2007
MECHANICAL FEE ¤390.00 02/06/2007
PERMIT FEE ¤4,200.00 02/06/2007
PLAN CHECK FEE ¤690.00 02/06/2007
PLUMBING FEE ¤390.00 02/06/2007
Fees Total Due: ¤0.00 Total Paid: ¤6,622.91