Permit #2006120165
Permit Details
Status: COED
| Parcel Id: 06-12-31-5815-00000-0200 |
| COMMERCIAL SQUARE FOOTAGE: 6291 sqft |
| Total Square Footage: 6291 sqft |
| Block: 00000 |
| Subdivision: 2118 - Town Center Phase I |
| Job Phone: (904)260-2900 |
| Location Address: 21 HOSPITAL DR |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 02/06/2007 |
| NOC: RECORDED |
| Applicant name: RONALD H FOSTER |
| Owner: PALM COAST MEDICAL SPECIALISTS LTD |
|
Address 21 HOSPITAL DR STE 200 PALM COAST, FL 32164 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤599,182.00 |
| Job Description: BUILD-OUT SUITE 160 - TOMOKA EYE ASSOCIATES |
| Type: CN |
Contractor
STELLAR GROUP INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
2900 HARTLEY ROAD JACKSONVILLE, FL 32257 |
CGC052029 (Exp: 08/31/2024) | 904-899-9214 |
Sub Contractors
RONALD A AUTREY
| Status | Location Address | State License Number | Phone |
| CANCEL |
PO Box 1799 Jacksonville, Fl., 32201 |
ECOOOO388 (Exp: 08/31/2018) | (904) 388-8000 |
ERIC TIMOTHY HOLCOMB
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
101 MUNDY MEMORIAL MT JULIET, TN 37122 |
CMC1249492 (Exp: 09/30/2008) | (800)222-1819 | (615)773-8108 |
GARY S WELBORN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1709 North Nova Road Holly Hill, FL 32117 |
CFC037140 (Exp: 08/31/2018) | (386) 257-1172 | (386)252-5979 |
ANTHONY JAMES PARETE
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
6900 PHILLIPS INDUSTRIAL BLVD. JACKSONVILLE, FL 32256 |
CCC044057 (Exp: 08/31/2026) | (904)880-6005 | (904)880-3377 |
WILLIAM W GAY
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
524 STOCKTON STREET JACKSONVILLE, FL 32204 |
CMC008140 (Exp: 08/31/2020) | (904)388-2696 | 904-394-7944 |
JOHN W BARBER JR
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1514 BERNITA STREET JACKSONVILLE, FL 32211 |
CCC057141 (Exp: 08/31/2020) | (904)744-4067 | (904)744-4209 |
Inspection History
| Type | Request Date | Result | Inspector |
| UTILITY COMMERCIAL FINAL | 04/08/2008 | APPROVED | DSPENCER |
| FINAL COMPLETE BUILDING INSPECTION | 04/08/2008 | FINAL APPROVED | JLEVRAULT |
| FIRE FINAL | 04/04/2008 | APPROVED | JPATTEE |
| ELECTRICAL FINAL | 04/02/2008 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING FINAL | 03/28/2008 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS IS A REINSPECTION NEED DRAIN UNGLOGGED BEFORE BUILDING FINAL. | |||
| ELECTRICAL FINAL | 03/24/2008 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION NEED REVISIONS WHERE RECEPTACLES ARE ADDED. | |||
| PLUMBING FINAL | 03/11/2008 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: MISSING SINK @ FRONT OF OFFICE...........MARK 931-2912 | |||
| ELECTRICAL FINAL | 03/11/2008 | Disapproved -FEE REQUIRED | LHITES |
| Note: REVISED PLANS ARE NOT CORRECT TO THE UNIT. THERE ARE EXTRA OUTLETS AND PANEL POSITION IS NOT ACCORDING TO PLAN | |||
| H.V.A.C. FINAL | 03/11/2008 | APPROVED | JLEVRAULT |
| ABOVE CEILING | 11/27/2007 | APPROVED | JLEVRAULT |
| ABOVE CEILING | 11/26/2007 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: CEILING NOT READY. | |||
| FIREWALL FINAL INSPECTION | 11/26/2007 | APPROVED | JLEWIS |
| FLOOR OR WALL PENETRATION | 11/16/2007 | APPROVED | JPATTEE |
| COMMERCIAL POWER INSPECTION | 10/23/2007 | APPROVED | LHITES |
| 2ND ROUGH ELECTRICAL | 08/24/2007 | APPROVED | RMARVEL |
| SECOND ROUGH PLUMBING INSPECTION | 08/17/2007 | APPROVED | JGIBSON |
| H.V.A.C. ROUGH | 08/14/2007 | APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| FRAMING | 08/10/2007 | APPROVED | JHINDMAN |
| H.V.A.C. ROUGH | 08/09/2007 | CANCELLED BY INSPECTOR | JLEVRAULT |
| Note: THIS IS A REINSPECTION CALLED IN BY MISTAKE. | |||
| INSULATION INSPECTION | 08/09/2007 | APPROVED | JLEVRAULT |
| H.V.A.C. ROUGH | 08/08/2007 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: 1. TWO CONDENSATE PANS ARE TOO SMALL. 2. TRUNK LINE IS SIGNIFICANTLY OUT OF PLANE. | |||
| H.V.A.C. ROUGH | 08/07/2007 | Disapproved - NO FEE | JLEVRAULT |
| Note: CANCELLED BY CONTRACTOR. | |||
| FIRE SPRINKLER 2ND ROUGH HYDROSTATIC PRESSURE TEST | 07/18/2007 | APPROVED | JPATTEE |
| Note: THIS IS A REINSPECTION | |||
| FIRE SPRINKLER 1ST ROUGH | 07/12/2007 | APPROVED | JPATTEE |
| FIRE SPRINKLER 2ND ROUGH HYDROSTATIC PRESSURE TEST | 07/12/2007 | CANCELLED BY APPLICANT | JPATTEE |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 03/31/2008 | 04/01/2008 |
| Note: Released By: SKNOPF Approved for Release. REVISION -1600 duplex added ckt #3 -1639 duplex removed -1638 (2) duplex's removed ckt 73, 79 -1640 duplex added ckt #73 -Added undercounter light and switch at Dictation area Corridor 1607 -Added undercounter light and switch at Dictation area Corridor 1616 | |||
| ELEC | COMPLETE | 03/20/2008 | 03/20/2008 |
| Note: Released By: SKNOPF Approved for Release. Revision: Various electrical changes (see Electrical Comments 3-13-2008). Released per L.W. | |||
| ELEC | HOLD | 03/11/2008 | 03/13/2008 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application #2006120165 (Suite 160 Tomoka Eye Assoc. @ 21 Hospital Dr) 3/13/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E001-160: a. Identify load (KVA) requirements, or remove, equipment listed in Panel Schedule circuits 61, 63, 65 and 79. b. Was supplemental heat required for AHU's in this suite, and if so, please provide KVA load for Load Calculation verification. c. The following circuits are showing undersized loads. Please review and revise. Panel 160: 5,7,8,9,11,13,15,16,17,18,19,21,22,24,25,26,27,29,36,39. d. Water Heater load in panel schedule should be 9000VA to match P001-160. Please review and revise load, circuit breaker, disconnect and wire size. e. Revise Load Calculations to conform to NEC standards showing actual lighting, receptacle, largest motor, equipment and HVAC per NEC 220. f. Please note that the panel schedule labeling for room identification is not correct for all circuits. 2. E101-160: a. Lighting plan shows (14) type 'A', (12) type 'M', plus (5) type 'UC3' fixtures totaling 2146VA on circuit 8. Maximum allowable load on a 20A lighting circuit is 1920VA per NEC 210.19(A)(1). Please review and revise. b. Clarify switching on plan sheet for Janitor closet 1609. c. Identify ceiling fan load in fixture schedule and add load to respective circuits for rooms 1625, 1636 and 1637. d. Identify fixture load in fixture schedule for Owner-furnished recess fixtures shown in Optical Retail 1602 (quantity 39) for Load Calculation verification. e. Provide wall switch 'd' on plan sheet, and identify circuit for (3) switchleg 'd' type 'M' fixtures shown in Optical Retail 1602. Add load for fixtures in panel schedule. f. Verify switching for undercounter lights in Optical Lab 1603. Switching not shown. 3. E102-160: a. Identify receptacle circuit west wall Dilution Waiting room 1610, and add load into panel schedule. b. Identify receptacle circuit northeast corner Exam 7 room 1614, and add load into panel schedule. c. Identify actual equipment loads (nameplate) for refrigerator circuit 35, microwave circuit 28, and copier circuit 33. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| BLD | COMPLETE | 12/12/2007 | 12/13/2007 |
| Note: Released By: FREODICA Rev.- Misc. revisions. See listing on file. Changes are "clouded". Sheets A101/102/201/501/601/602, M101, E001/101/102. | |||
| FI1 | COMPLETE | 01/23/2007 | 01/25/2007 |
| Note: Released By: JPATTEE one(1) set of plan sent to FD on 1/8/2007. | |||
| BLD | COMPLETE | 01/16/2007 | 02/01/2007 |
| Note: Released By: CCOTE Approved for Release. Review by Fred R. | |||
| BLD | HOLD | 12/14/2006 | 01/04/2007 |
| Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2006120165 - Tomoka Eye Associates - Suite160 1. Dwg. No. M001-160: a. VAV-1-8-A5 was indicated on VAV Box Unit Schedule but can not be found on plan. b. BD-1-8-A was shown on plan but not indicated on VAV Box Unit Schedule. 2. Dwg. No. M101-160: a. Return air from Ascan 1631 was missing. b. Location of space sensor for VAV-1-8-B5 was not shown on plan. 3. Dwg. No. P101-160: a. Provide reference information on condensate lines tied to existing system. b. Show on plan AHU's and condensate lines. 4. Dwg. No. P101-160/P801-160: a. Plumbing fixtures for Exam 5 (1618), Exam 12 (1620) and Contact Lens 1601 did not match with sanitary riser diagram. b. Floor drain, FD-1 for handicapped toilet 1646 was missing on sanitary riser diagram. 5. Dwg. No. E102-160: a. Electrical supply to Exhaust fan EF-1-8-A was missing. Instead, there were exhaust fans for all toilets but none of these were shown on mechanical drawing. Please clarify. b. Location of water heater on janitor's closet 1609 did not match with plumbing, mechanical and architectural drawings. | |||
| DSD | COMPLETE | 01/30/2007 | |
| Note: Released By: DCHAUDOIN | |||
| UD1 | COMPLETE | 01/25/2007 | |
| Note: Released By: CJOHNSON | |||
| BLD | COMPLETE | 03/27/2008 | |
| Note: Released By: JJOSEPH Revision: paper towel dispensers pass through cabinet at reception 1645 desk area deleted pass through from waiting room to reception is 1-10' planter in waiting area room 1600 has been removed. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADDITIONAL FEE | ¤40.00 | 04/04/2008 |
| ADDITIONAL FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REVISION | ¤40.00 | 04/04/2008 |
| REVISION | ¤80.00 | 04/04/2008 |
| REVISION | ¤80.00 | 04/04/2008 |
| ADMIN FEE | ¤20.00 | 02/06/2007 |
| ELECTRIC FEE | ¤390.00 | 02/06/2007 |
| FIRE PLANS REVIEW | ¤62.91 | 02/06/2007 |
| MECHANICAL FEE | ¤390.00 | 02/06/2007 |
| PERMIT FEE | ¤4,200.00 | 02/06/2007 |
| PLAN CHECK FEE | ¤690.00 | 02/06/2007 |
| PLUMBING FEE | ¤390.00 | 02/06/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤6,622.91 |