I want to search for...

Permit #2006120166

Permit Details

Status: COED

Parcel Id: 06-12-31-5815-00000-0200
COMMERCIAL SQUARE FOOTAGE: 6291 sqft
Total Square Footage: 6291 sqft
Block: 00000
Subdivision: 2118 - Town Center Phase I
Job Phone: (904)260-2900
Location Address: 21 HOSPITAL DR
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 02/06/2007
NOC: RECORDED
Applicant name: RONALD H FOSTER
Owner: PALM COAST MEDICAL SPECIALISTS LTD

Address

21 HOSPITAL DR STE 200

PALM COAST, 0

Lot: 0200
Contracted Stated Job Value: ¤374,553.00
Job Description: BUILD-OUT SUITE 170 "DRC PAIN MANAGEMENT"
Type: CN

Contractor

STELLAR GROUP INC
Status Location Address State License Number Phone
INACTIVE

2900 HARTLEY ROAD

JACKSONVILLE, FL 32257

CGC052029 (Exp: 08/31/2024) 904-899-9214

Sub Contractors

ERIC TIMOTHY HOLCOMB
Status Location Address State License Number Phone Fax
CANCEL

101 MUNDY MEMORIAL

MT JULIET, TN 37122

CMC1249492 (Exp: 09/30/2008) (800)222-1819 (615)773-8108
GARY S WELBORN
Status Location Address State License Number Phone Fax
CANCEL

1709 North Nova Road

Holly Hill, FL 32117

CFC037140 (Exp: 08/31/2018) (386) 257-1172 (386)252-5979
ANTHONY JAMES PARETE
Status Location Address State License Number Phone Fax
INACTIVE

6900 PHILLIPS INDUSTRIAL BLVD.

JACKSONVILLE, FL 32256

CCC044057 (Exp: 08/31/2026) (904)880-6005 (904)880-3377
RONALD A AUTREY
Status Location Address State License Number Phone
CANCEL

PO Box 1799

Jacksonville, Fl., 32201

ECOOOO388 (Exp: 08/31/2018) (904) 388-8000
WILLIAM W GAY
Status Location Address State License Number Phone Fax
DECEASED

524 STOCKTON STREET

JACKSONVILLE, FL 32204

CMC008140 (Exp: 08/31/2020) (904)388-2696 904-394-7944
JOHN W BARBER JR
Status Location Address State License Number Phone Fax
INACTIVE

1514 BERNITA STREET

JACKSONVILLE, FL 32211

CCC057141 (Exp: 08/31/2020) (904)744-4067 (904)744-4209

Inspection History

Type Request Date Result Inspector
UTILITY COMMERCIAL FINAL 04/08/2008 APPROVED DSPENCER
FINAL COMPLETE BUILDING INSPECTION 04/08/2008 FINAL APPROVED JLEVRAULT
FIRE FINAL 04/04/2008 APPROVED JPATTEE
ELECTRICAL FINAL 04/02/2008 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
ELECTRICAL FINAL 03/31/2008 Disapproved -FEE REQUIRED LHITES
Note: NEED APPROVED REVISIONS AT JOB SITE BEFORE IT CAN BE INSPECTED
H.V.A.C. FINAL 03/19/2008 APPROVED JLEVRAULT
PLUMBING FINAL 03/19/2008 FINAL APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
PLUMBING FINAL 03/18/2008 Disapproved -FEE REQUIRED PGALLMANN
Note: WATER EXCEEDS MAX TEMP CODE RRQUIREMENT OF 120 DEGREES....PAUL..........931-7400
ABOVE CEILING 12/10/2007 APPROVED JLEVRAULT
Note: THIS IS A REINSPECTION
ABOVE CEILING 11/26/2007 Disapproved -FEE REQUIRED JLEVRAULT
Note: CEILING NOT READY.
FIREWALL FINAL INSPECTION 11/26/2007 APPROVED JLEWIS
FLOOR OR WALL PENETRATION 11/16/2007 APPROVED JPATTEE
COMMERCIAL POWER INSPECTION 10/23/2007 APPROVED LHITES
2ND ROUGH ELECTRICAL 10/01/2007 APPROVED - AS NOTED LHITES
Note: WALLS ONLY
INSULATION INSPECTION 09/12/2007 APPROVED JHINDMAN
2ND ROUGH ELECTRICAL 09/11/2007 APPROVED - AS NOTED LHITES
Note: UN-BUNDLE MC WHERE BEFORE ENTRY TO PANEL
FRAMING 09/04/2007 APPROVED JHINDMAN
SECOND ROUGH PLUMBING INSPECTION 08/22/2007 APPROVED JGIBSON
FRAMING 08/21/2007 APPROVED JHINDMAN
H.V.A.C. ROUGH 08/21/2007 CANCELLED BY INSPECTOR JLEVRAULT
Note: ALREADY APPROVED.
H.V.A.C. ROUGH 08/14/2007 APPROVED JLEVRAULT
FIRE SPRINKLER 2ND ROUGH HYDROSTATIC PRESSURE TEST 07/18/2007 APPROVED JPATTEE
Note: THIS IS A REINSPECTION
FIRE SPRINKLER 1ST ROUGH 07/12/2007 APPROVED JPATTEE
FIRE SPRINKLER 2ND ROUGH HYDROSTATIC PRESSURE TEST 07/12/2007 CANCELLED BY APPLICANT JPATTEE

Review History

Department Status Date In Date Out
ELEC COMPLETE 03/31/2008 04/01/2008
Note: Released By: SKNOPF Approved for Release. Revision - Added (2) duplex rcpts on ckt 44 in room 1702 - Added a duplex rcpt on ckt 13 in room 1716 - Updated some circuit loads in panel
ELEC COMPLETE 03/20/2008 03/20/2008
Note: Released By: SKNOPF Approved for release. Revision: Various electrical changes (see electrical comments 3-17-2008). Released by L.W.
ELEC HOLD 03/11/2008 03/17/2008
Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Permit #2006120166 (Suite 170 Pain Management @ 21 Hospital Dr) 3/17/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E001-170: a. Provide nameplate load for the following equipment: AHU-1-6-A, CU-1-6-A, VAV-1-6-B2, VAV-1-6-B4, VAV-1-6-B5, BD-1-6-B. Mechanical Schedule has insufficient electrical data for load calculation verification. b. The following circuits in the panel schedule have undersized loads shown: 7, 15, 17. Please review and revise. c. The following circuits in the panel schedule are missing their load: 44, 46, 48, 49, 50, 51, 53, 55. Please review and revise. d. Please identify the nameplate load of the following equipment (circuit) for load calculation verification: copier (25), refrigerator (31), microwave (53). e. Please revise Load Calculation to conform to NEC 220 using actual lighting, receptacle, equipment, HVAC and largest motor loads. 2. E101-170: a. Waiting 1700 and Procedure 1716 both show recess downlights but there is no current fixture identified in the Luminaire Schedule. Identify fixture type for these fixtures and provide total wattage each fixture type for load calculation verification. b. Identify circuit for Corridor 1705/1709 2'x4' and 2'x2' fixtures. 3. E102-170: a. Water Heater is shown in both the panel schedule and on the plumbing schedule as 9000VA @ 208V 1ph yielding over 43A. The Water Heater is shown on E102 with a 30A disconnect. Please review and revise. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us
FI1 COMPLETE 01/23/2007 01/25/2007
Note: Released By: JPATTEE
BLD COMPLETE 01/16/2007 02/01/2007
Note: Released By: CCOTE Approved for Release. Review by Fred R.
BLD HOLD 12/14/2006 01/04/2007
Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2006120166 - PRC Pain Management - Suite170 1. Dwg. No. A101-170: a. Wall separation between Suite 170 and Suite 180 was indicated as 1- hr Type 1 existing exterior wall but on the shell (existing) building that wall was indicated as Type 12, 1-hr rated fire and smoke wall. Please clarify. 2. Dwg. No. M101-170: a. Return air from Utility Room 1723 was missing. 3. Dwg. No. P101-170: a. Provide reference information on condensate lines tied to existing system. b. Show on plan AHU's and condensate lines. 4. Dwg. No. E102-170: a. Electrical supply to Exhaust fan EF-1-6-A was missing. However. there were exhaust fans shown on all toilets but none of them were shown on mechanical drawing. Please clarify.
DSD COMPLETE 01/30/2007
Note: Released By: DCHAUDOIN
UD1 COMPLETE 01/25/2007
Note: Released By: CJOHNSON
BLD COMPLETE 03/27/2008
Note: Released By: JJOSEPH REvision: paper towel dispenser delete the viewbox location Delete - hi-hat in center of soffit on north wall

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADDITIONAL FEE ¤40.00 04/04/2008
ADDITIONAL FEE ¤40.00 04/04/2008
REINSPECTION FEE ¤40.00 04/04/2008
REINSPECTION FEE ¤40.00 04/04/2008
REINSPECTION FEE ¤40.00 04/04/2008
REVISION ¤40.00 04/04/2008
REVISION ¤80.00 04/04/2008
REVISION ¤40.00 04/04/2008
ADMIN FEE ¤20.00 02/06/2007
ELECTRIC FEE ¤255.00 02/06/2007
FIRE PLANS REVIEW ¤62.91 02/06/2007
MECHANICAL FEE ¤255.00 02/06/2007
PERMIT FEE ¤2,625.00 02/06/2007
PLAN CHECK FEE ¤431.25 02/06/2007
PLUMBING FEE ¤255.00 02/06/2007
Fees Total Due: ¤0.00 Total Paid: ¤4,264.16