I want to search for...
Permit #2006120183
Permit Details
Status: COED
| Parcel Id: 06-12-31-5815-00000-0200 |
| Total Square Footage: 1973 sqft |
| Block: 00000 |
| Subdivision: 2118 - Town Center Phase I |
| Job Phone: (904)260-2900 |
| Location Address: 21 HOSPITAL DR |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 02/27/2007 |
| NOC: RECORDED |
| Applicant name: RONALD H FOSTER |
| Owner: PALM COAST MEDICAL SPECIALISTS LTD |
|
Address 21 HOSPITAL DR STE 200 PALM COAST, FL 32164 |
| Lot: 0200 |
| Contracted Stated Job Value: ¤209,407.00 |
| Job Description: GOODWIN INTERNAL MEDICINE BUILD-OUT SUITE 280 |
| Type: CN |
Contractor
STELLAR GROUP INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
2900 HARTLEY ROAD JACKSONVILLE, FL 32257 |
CGC052029 (Exp: 08/31/2024) | 904-899-9214 |
Sub Contractors
RONALD A AUTREY
| Status | Location Address | State License Number | Phone |
| CANCEL |
PO Box 1799 Jacksonville, Fl., 32201 |
ECOOOO388 (Exp: 08/31/2018) | (904) 388-8000 |
ERIC TIMOTHY HOLCOMB
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
101 MUNDY MEMORIAL MT JULIET, TN 37122 |
CMC1249492 (Exp: 09/30/2008) | (800)222-1819 | (615)773-8108 |
GARY S WELBORN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1709 North Nova Road Holly Hill, FL 32117 |
CFC037140 (Exp: 08/31/2018) | (386) 257-1172 | (386)252-5979 |
ANTHONY JAMES PARETE
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
6900 PHILLIPS INDUSTRIAL BLVD. JACKSONVILLE, FL 32256 |
CCC044057 (Exp: 08/31/2026) | (904)880-6005 | (904)880-3377 |
WILLIAM W GAY
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
524 STOCKTON STREET JACKSONVILLE, FL 32204 |
CMC008140 (Exp: 08/31/2020) | (904)388-2696 | 904-394-7944 |
JOHN W BARBER JR
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1514 BERNITA STREET JACKSONVILLE, FL 32211 |
CCC057141 (Exp: 08/31/2020) | (904)744-4067 | (904)744-4209 |
Inspection History
| Type | Request Date | Result | Inspector |
| UTILITY COMMERCIAL FINAL | 04/08/2008 | APPROVED | DSPENCER |
| FINAL COMPLETE BUILDING INSPECTION | 04/08/2008 | FINAL APPROVED | JLEVRAULT |
| FIRE FINAL | 04/04/2008 | APPROVED | JPATTEE |
| H.V.A.C. FINAL | 04/02/2008 | FINAL APPROVED | JLEVRAULT |
| Note: THIS IS A REINSPECTION | |||
| ELECTRICAL FINAL | 04/02/2008 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ELECTRICAL FINAL | 03/24/2008 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: NEED REVISIONS WHERE RECEPTACLES ARE ADDED. | |||
| PLUMBING FINAL | 03/19/2008 | FINAL APPROVED | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING FINAL | 03/18/2008 | Disapproved - NO FEE | PGALLMANN |
| Note: THIS IS A REINSPECTION | |||
| H.V.A.C. FINAL | 03/14/2008 | Disapproved -FEE REQUIRED | JLEVRAULT |
| Note: BATH EXHAUST FANS NOT OPERATING. | |||
| PLUMBING FINAL | 03/14/2008 | Disapproved - NO FEE | PGALLMANN |
| Note: 1) NO HOT WATER. 2) SUITE 120? FLUSH VALVE TAIL PIECE LEAKING DUE TO LACK OF SUPPORT. SET SCREW MISSING FROM WALL BRACKET. | |||
| ABOVE CEILING | 01/02/2008 | APPROVED | RMARVEL |
| FIREWALL FINAL INSPECTION | 12/14/2007 | APPROVED | JPATTEE |
| FIREWALL INSPECTION | 12/10/2007 | Disapproved -FEE REQUIRED | JPATTEE |
| Note: Penetrations not sealed throughout, spray application not heavy enough | |||
| COMMERCIAL POWER INSPECTION | 12/07/2007 | APPROVED | JHINDMAN |
| 2ND ROUGH ELECTRICAL | 10/01/2007 | APPROVED | LHITES |
| INSULATION INSPECTION | 10/01/2007 | APPROVED | JHINDMAN |
| 2ND ROUGH ELECTRICAL | 09/27/2007 | APPROVED | LHITES |
| Note: UNIT 280 WALLS ONLY. ALSO MIDDLE CORRIDOR SAME LEVEL | |||
| FIREWALL INSPECTION | 09/21/2007 | APPROVED - AS NOTED | JPATTEE |
| Note: Floor penetrations | |||
| SECOND ROUGH PLUMBING INSPECTION | 09/10/2007 | APPROVED | JGIBSON |
| H.V.A.C. ROUGH | 09/04/2007 | APPROVED | JMCGOWEN |
| FRAMING | 08/22/2007 | APPROVED | JHINDMAN |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 03/31/2008 | 03/31/2008 |
| Note: Released By: SKNOPF Approved for Release. Revision - Room 2800 TV receptacle added | |||
| ELEC | COMPLETE | 03/20/2008 | 03/20/2008 |
| Note: Released By: SKNOPF Approved for Release. Revision: Various electrical changes (see electrical comments 3-19-2008). Released by L.W. | |||
| ELEC | HOLD | 03/18/2008 | 03/19/2008 |
| Note: Held By: SKNOPF CITY OF PALM COAST BUILDING DIVISION Comments on Revision to Permit #2006120183 (Suite 280 Goodwin Internal Medicine @ 21 Hospital Dr) 3/19/2008 The following items must be resolved in order to complete the Building Permit plan review. Electrical Comments: 1. E001-280: a. The following loads are undersized in the panel schedule: circuits 13, 17. Please review and revise. b. Please provide nameplate loads for the following equipment (circuit): copier (19), and refrigerator (25), for load calculation verification. c. Water Heater circuit 39:41 is listed in the panel schedule as 12KW with a 70A circuit breaker. Please revise load and circuit breaker size in panel. d. Please revise the Load Calculation to conform to NEC 220 using actual lighting, receptacle, equipment, HVAC, and motor loads. 2. E102-280: Floor plan shows BD-2-6A on circuit 21. Panel Schedule lists this circuit as 'spare'. VAV transformer is listed in panel as circuit 31. Please review and revise. …………………………………………… Susan J. Knopf Plans Examiner City of Palm Coast - Building Division 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-2463 [fax]: (386) 986-3781 [email]: sknopf@ci.palm-coast.fl.us | |||
| FI1 | COMPLETE | 01/24/2007 | 02/16/2007 |
| Note: Released By: JPATTEE 1. Sent one (1) set of drawing to FD on 1/16/07. 2. Sent one (1) set of revised drawing to FD on 1/24/07. | |||
| BLD | COMPLETE | 01/16/2007 | 02/23/2007 |
| Note: Released By: LWOODROME | |||
| BLD | HOLD | 12/14/2006 | 01/16/2007 |
| Note: Held By: FREODICA CITY OF PALM COAST BUILDING DIVISION Comment on Permit Application No. 2006120183 - Goodwin Internal Medicine - Suite 280: 1. Dwg. No. E102-280/E103-280: a. Electrical drawing plans showed individual exhaust fan for each toilet and nothing on roof. Mechanical drawing showed only One (1) exhaust fan located on roof. Please clarify. | |||
| DSD | COMPLETE | 01/30/2007 | |
| Note: Released By: DCHAUDOIN | |||
| UD1 | COMPLETE | 01/25/2007 | |
| Note: Released By: CJOHNSON | |||
| BLD | COMPLETE | 03/27/2008 | |
| Note: Released By: JJOSEPH REvision: paper towel dispenser exam room 2 and exam room 4 sections upper cabinetry protruding into windows not installed. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADDITIONAL FEE | ¤40.00 | 04/04/2008 |
| ADDITIONAL FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| REINSPECTION FEE | ¤40.00 | 04/04/2008 |
| RENEW PERMIT FEES | ¤40.00 | 04/04/2008 |
| REVISION | ¤40.00 | 04/04/2008 |
| REVISION | ¤40.00 | 04/04/2008 |
| REVISION | ¤40.00 | 04/04/2008 |
| ADMIN FEE | ¤20.00 | 02/27/2007 |
| ELECTRIC FEE | ¤155.64 | 02/27/2007 |
| FIRE PLANS REVIEW | ¤25.00 | 02/27/2007 |
| MECHANICAL FEE | ¤155.64 | 02/27/2007 |
| PERMIT FEE | ¤1,465.85 | 02/27/2007 |
| PLAN CHECK FEE | ¤240.82 | 02/27/2007 |
| PLUMBING FEE | ¤155.64 | 02/27/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤2,578.59 |