Permit #2006120435

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00030-0130
CONDITIONED SPACE: 1819 sqft
GARAGE: 257 sqft
OPENED PORCH (WITH ROOF) : 62 sqft
OPENED PORCH (WITH ROOF) : 151 sqft
Total Square Footage: 2289 sqft
Block: 00030
Subdivision: -
Job Phone: (386)423-6670
Location Address: 58 EMERSON DR
Type: BCR - BUILDING COMMERCIAL RESIDENTIAL -CONDO
Issue Date: 02/22/2007
NOC: RECORDED
Applicant name: ADAM M BEATY
Owner: AFFORDABLE FLORIDA HOMES

Address

4070 MONZO DRIVE

NEW SMYRNA BEACH, FL 32168

Lot: 0130
Contracted Stated Job Value: ¤341,148.00
Job Description: 2 UNIT TOWN HOUSE
Type: CN

Contractor

AFFORDABLE FLORIDA HOMES, INC.
Status Location Address State License Number Phone Fax
CANCEL

4070 MONZA DRIVE

NEW SMYRNA BEACH, FL 32168

CRC1328621 (Exp: 09/30/2008) (386)423-6670 (866)721-6888

Sub Contractors

RICHARD R EDWARDS
Status Location Address State License Number Phone
CANCEL

P. O. Box 1637

Bunnell, FL 32110

ER0011603 (Exp: 08/31/2022) (386) 437-1537
SINCLAIR W STICKLE
Status Location Address State License Number Phone Fax
DECEASED

15 HARGROVE GRADE BLD 2 UNIT G

PALM COAST, FL 32137

CAC052428 (Exp: 08/31/2018) 386-446-1114 (386)446-1278
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 11/20/2007 FINAL APPROVED ACOOPER
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 11/15/2007 Disapproved -FEE REQUIRED ACOOPER
Note: Side A: Add light cover in front bedroom closet Side B: Complete receptacle installation and add required plate on island.
LANDSCAPE FINAL 11/08/2007 APPROVED WBUTLER
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 11/05/2007 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 10/29/2007 Disapproved -FEE REQUIRED GLALIMA
Note: WATER IS PONDING 4 '' TO 6'' AT INSIDE CORNER OF HOUSE OR SIDE WALK . I DID CALL BUILDER .
TRAFFIC ENGINEER 10/15/2007 APPROVED KKRUGER
UTILITY COMMERCIAL FINAL 10/15/2007 APPROVED KKING
UTILITY COMPANY FINAL 10/15/2007 APPROVED MBACON
LANDSCAPE FINAL 10/15/2007 Disapproved -FEE REQUIRED WBUTLER
Note: Final is disapproved due to the required shade trees not being the minimum size required of 2" caliper as measured 6" above grade. Trees are 15 gallon container size and need to be 30-gallon. Also the left and right front corners of the house have not been wrapped around the corner with 3 shrubs and this needs to be done. Finally, the shrub variety selected uses crotons very heavily and they are not approved foundation shrubs as they are susceptable to freezing in the winter. Bill Butler
RESIDENTIAL EARLY POWER 10/12/2007 APPROVED LHITES
Note: THIS IS A REINSPECTION
RESIDENTIAL EARLY POWER 10/10/2007 Disapproved -FEE REQUIRED RMARVEL
Note: LOOSEN FIXTURE WIRE IN DINING ROOM LIGHT.
DRIVEWAY 10/04/2007 APPROVED MBRENNAN
Note: This is the second part of a 2 part pour.\\wk
DRIVEWAY 10/03/2007 Disapproved -FEE REQUIRED GLALIMA
Note: THIS IS A REINSPECTION / TOLD BUILDER THAT HE IS TO CALL IN FOR A INSPECTION BEFOR 2nd POUR . THIS is A TO PART POUR . ON OCT 4 TH 2007 WENT BY JOB 4 DRIVEWAYS WERE POURED WITH OUT INSPECTION. NEED CORE TEST.
DRIVEWAY 10/01/2007 Disapproved -FEE REQUIRED GLALIMA
INSULATION INSPECTION 07/26/2007 APPROVED DROCKWELL
Note: Requested by Adam
FIREWALL INSPECTION 07/26/2007 APPROVED DROCKWELL
Note: Requested by Adam
ALL ROUGH 06/29/2007 APPROVED JHINDMAN
Note: Requested by Adam permits and paperwork need to be for both sides on job site
LATH /BRICK FLASHING 06/22/2007 APPROVED DROCKWELL
Note: per the request of ADam
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/19/2007 APPROVED - AS NOTED DROCKWELL
Note: T-101 T102 T107 T109 TRUSS STRAPS ARE OFFSET . SOME AS MUCH AS 11/2.REPAIR BEFORE ALL ROUGH
LINTEL 05/10/2007 APPROVED RMARVEL
Note: Adam called to schedule a lintel inspection for 5/10/07
FOUNDATION SURVEY APPROVED BY STORMWATER 04/09/2007 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 03/30/2007 APPROVED DROCKWELL
Note: ADAM CALLED TO SCHEDULE A MONO SLAB INSPECTION FOR 3/30/07
FIRST ROUGH PLUMBING INSPECTION 03/22/2007 APPROVED PGALLMANN

Review History

Department Status Date In Date Out
ZON COMPLETE 09/24/2007 09/27/2007
Note: Released By: JGONZALEZ
SW1 COMPLETE 09/20/2007 09/24/2007
Note: Released By: LAPTEKAR widening driveway 4' to 16' wide
SW1 COMPLETE 09/07/2007 09/07/2007
Note: Released By: WKINELL Reveived new topo survey/LGP.\\wk
SW1 HOLD 08/23/2007 08/23/2007
Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are different than we expected. This is part of an extended depth swale with very little margin of error allowable. This property shares a common benchmark with lot 12 to the left. There was a discrepancy found on lot 12 requiring that new elevations be shot. Due to the critical nature of this section and the common bench mark it has been requested that both lots elevations be revised together. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised.
UD1 COMPLETE 02/12/2007 02/19/2007
Note: Released By: CJOHNSON
BLD COMPLETE 02/09/2007 02/13/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet.
BLD HOLD 02/02/2007 02/06/2007
Note: Held By: CCOTE CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2006120435 (58 Emerson Dr) 2/06/07 The following items must be submitted/clarified in order to complete the Building Permit Application plan review. 1. Energy Calculations. a. The energy forms submitted reference the Central Climate zone which should be North. Revise forms and resubmit. b. The energy forms submitted indicate an incorrect under attic square footage. Revise this line and verify wall areas and correct value for adjacent concrete wall for area between units. ------------------------------------------------- Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us -------------------------------------------------
BLD HOLD 01/12/2007 01/17/2007
Note: Held By: CCOTE CITY OF PALM COAST BUILDING DIVISION Comments on Permit Application No. 2006120435 (58 Emerson Dr) 1/17/07 The following items must be submitted/clarified in order to complete the Building Permit Application plan review. 1. Party Wall. a. This Section indicates an 18" vertical extension above adjacent roof sheathing which does not meet the code requirement of 30" per Florida Building Code Section 705.6. An alternate acceptable method is outlined in Section 705.6 Exception 4. Please revise drawings as required to meet code compliance. b. This Section indicates an 18" extension at the roof overhang areas. If the exception above is to be used then this detail would require a revision showing how area would be constructed to comply with Florida Building Code Section 705.5.2 Exception 3. c. No indication is made as to where the dryer and bathroom is to be exhausted. Refer to Florida Building Code Section 705 for distances required from fire wall in walls and roof. Indicate location on the drawings. d. The elevations do not match the floor plans. Revise to show correctly. e. The elevations do not show the fire wall extending through the garage roof and lanai/family room roof. i. The overhangs cross the property line which is not allowed. ii. The fire wall must meet the requirements of item 1a above. f. Section does not indicate that the ledger is separated from the concrete with a moisture barrier and it is not indicated as pressure treated. Review and revise as required. g. Section has a note indicating two pre engineered trusses each side of concrete wall however this is not what is shown on this section or on the truss drawings. Revise note as required. h. Section has notes that reference Florida Residential Code Section R317.2 and R317.2.4. These sections do no apply to this permit since it does not meet the requirements of a townhouse. Fire Wall shall comply with Florida Building Code Section 705. 2. Exterior Finish. a. Indicate how the finish over wood framed walls will be provided and installed to comply with the Florida Building Code 2005 Supplement Section "R703.11 Weather Protection". All wall surfaces that are not masonry or concrete shall be provided with weather protection per one of the approved building materials listed in Florida Building Code 2005 Supplement Table R703.11. Stucco, as indicated on the drawings, is acceptable if applied per ASTM C926 and the following criteria: i. Exterior Stucco shall be installed to prevent bonding to water resistive barrier per FRC, Section R703.2.1. ii. Exterior stucco shall be installed per ASTM C926; 3 coats with a minimum thickness of 7/8-inch per FRC, Section R703.6 & Table R703.11. iii. Installation of exterior lathing shall be installed to meet the requirements of ASTM C1063 per FRC, Section R703.6.2. b. The drawings indicate a cementituous coating. The Florida Building Code 2006 supplement section 1403.2 was modified to state "…that a weather-resistant exterior wall envelope shall not be required over concrete or non-porous masonry walls…" This means that, decorative cementituous coating CAN NOT, be used over exterior concrete or masonry walls, unless the they can be shown to be non-porous. Based on this information the drawings need to be revised to list one of the approved wall coverings per section R703.11 or testing must be provided showing that wall construction is non-porous. Stucco or Exterior Cement Portland Plaster are the acceptable terms from this code section. c. Provide detail/information for drainage system required between wood frame wall base over mass wall assembly as required per Florida Residential Code Section 1403.9. 3. Energy Calculations. a. New Energy Form 600A-04R / Computer program FLA/RES-4 version 4.5 must be used. Submit revised forms to comply with the Florida Building Code 2006 Supplement. b. Energy software updated to include jurisdiction for Palm Coast, Jurisdiction 281500. c. Section 13-607.1.ABC.1 states …. "An HVAC sizing calculation shall be performed on the building and shall be attached to the Form 600 submitted when application is made for a building permit,…in accordance with ACCA Manual J, ACCA Manual N, or the ASHRAE Cooling and Heating Load Calculation Manual." In Chapter 13 there is a Subchapter 13-3 titled Referenced Standards and Organizations; In this chapter you will find ACCA with the standard reference number "ACCA Manual J-2003 Residential Load Calculation, Eighth Edition with posed updates/errata" and it states the referenced in code section number as "607.ABC.1". This makes it clear that the eighth edition must be used. Provide a sizing calculation meeting these code requirements. d. Information on energy forms appears to be for both units. Revise to show information for 58 Emerson Drive only. 4. Gable End. a. Provide information for type/size/spacing of fasteners to be used for attaching exterior wall sheathing. b. Provide information for attaching gable end truss to concrete wall below. 5. Floor Sheathing. a. Provide information for type/size/spacing of fasteners to be used for attaching floor sheathing. 6. Interior Bearing Wall Section. a. The floor plans and truss layout do not show any interior bearing walls therefore this section shall be removed. 7. Foundation Plan. a. The foundation detail markers shown on slab plan are incorrect. Review and revise as required. b. Indicate spacing of vertical rods. 8. Sheet 7. a. Windload calculation note references the 2001 building code. Revise to show current code version. b. Windload calculation note references masonry walls. Remove note. 9. Slab. a. The drawings have various references regarding slab specification such as 2500 & 3000 psi, fibermesh & WWM, 3-1/2" & 4". Revise drawings to show consistent information. 10. Roof Sheathing. a. Drawings have various roof sheathing thicknesses specified such as 5/8" CDX, 7/16" OSB, 15/32" C-D plywood. Revise drawings to show consistent information. *Clearly indicate on drawing plans what portion of floor plan and other drawings pertain to this permit for this address. Manually crossing out areas is acceptable. ------------------------------------------------- Carl L. Cote, R.A. Senior Plans Examiner City of Palm Coast - Building Department 2 Commerce Boulevard Palm Coast, Florida 32164-3216 [tel]: (386) 986-4753 [fax]: (386) 986-3781 [email]: ccote@ci.palm-coast.fl.us -------------------------------------------------
SW1 COMPLETE 01/08/2007 01/08/2007
Note: Released By: LAPTEKAR
ZON HOLD 01/05/2007 01/08/2007
Note: Held By: ECOYNE need plant schedule survey states lot 13 warranty states lots 12 & 13
DSD COMPLETE 12/21/2006 01/05/2007
Note: Released By: DCHAUDOIN Held By: DCHAUDOIN awaiting addresses from E-911. Sent file to zoning for review
SW1 HOLD 12/21/2006 12/22/2006
Note: Held By: LAPTEKAR Topo survey is missing a clearly identified benchmark. The FFE of the house on lot #14 is missing and the pipe inverts of lot #14 are missing.
ZON HOLD 01/09/2007
Note: Held By: ECOYNE received plant schedule need DSD to imput addresses
ZON COMPLETE 01/12/2007
Note: Released By: ECOYNE sent to building - address needs to be corrected with DSD

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 01/09/2008
EARLY POWER INSPECTION ¤40.00 01/09/2008
FIRE RESIDENTIAL IMPACT FEE ¤179.37 01/09/2008
PARKS IMPACT FEE ¤1,159.02 01/09/2008
REINSPECTION FEE ¤40.00 01/09/2008
REINSPECTION FEE ¤40.00 01/09/2008
REINSPECTION FEE ¤40.00 01/09/2008
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 01/09/2008
STORMWATER REINSPECTION FEE ¤35.00 01/09/2008
STORMWATER REINSPECTION FEE ¤35.00 01/09/2008
STORMWATER REINSPECTION FEE ¤35.00 01/09/2008
SW REVISION ¤40.00 01/09/2008
TRANSPORTATION IMPACT FEE ¤3,631.83 01/09/2008
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 02/22/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 02/22/2007
STORM WATER PERMIT FEES ¤80.00 02/22/2007
PARKS IMPACT FEE 4/1/06 ¤1,159.02 02/22/2007
PLAN CHECK FEE ¤136.80 02/22/2007
PLUMBING FEE ¤235.20 02/22/2007
RADON FEE ¤11.45 02/22/2007
FIRE IMPACT FEE 4-1-06 ¤179.37 02/22/2007
MECHANICAL FEE ¤235.20 02/22/2007
PERMIT FEE ¤1,333.80 02/22/2007
ADMIN FEE ¤20.00 02/22/2007
BUILDING CODE ADMIN FUND ¤11.45 02/22/2007
ELECTRIC FEE ¤235.20 02/22/2007
Fees Total Due: ¤0.00 Total Paid: ¤19,784.54