I want to search for...
Permit #2007010052
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7013-00250-0050 |
| PATIO/DECK (NO ROOF) : 438 sqft |
| Total Square Footage: 858 sqft |
| Block: 00250 |
| Subdivision: - |
| Job Phone: (386)736-2828 |
| Location Address: 75 BRONSON LN |
| Type: PO - POOL |
| Issue Date: 01/12/2007 |
| NOC: Unknown |
| Applicant name: KEITH LANPHEAR |
| Owner: UNGER GERARD R & GAIL C H&W |
|
Address 75 BRONSON LANE PALM COAST, FL 32137 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤39,100.00 |
| Job Description: SPA WITH A SCREEN ENCLOSURE |
| Type: CN |
Contractor
FREEDOM HOMES POOLS & SPAS INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2001 LARACHMONT DRIVE DELAND, FL 32724 |
CPC025522 (Exp: 09/30/2008) | (904)824-8499 | (386)734-8070 |
Sub Contractors
THOMAS M HENRY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
85-B S. HWY.17-92 DE BARY, FL 32713 |
EC0002683 (Exp: 08/31/2026) | (386)668-0691 | (386)668-8908 |
Inspection History
| Type | Request Date | Result | Inspector |
| STORMWATER FINAL INSPECTION | 05/23/2007 | Disapproved -FEE REQUIRED | DRANDALL |
| Note: remove all concrete washout from across street adj. property.....seed & straw same area | |||
| UTILITY COMPANY FINAL | 05/23/2007 | APPROVED | TSCHWEERS |
| POOL DECK INSPECTION | 02/13/2007 | APPROVED | ACOOPER |
| Note: THIS IS A REINSPECTION | |||
| POOL DECK INSPECTION | 02/09/2007 | Disapproved - NO FEE | MMOORE |
| Note: 1. NATIONAL ELECTRIC CODE (NEC) # 680.26 .... "BONDING EQUIPOTENTIAL PLANE" 2. ONE #5 REBAR TO BE RUN AROUND THE POOL PERIMETER AT 3' FROM THE POOL EDGE 3. 30" OF LAP REQUIRED AT REBAR 4. BOND REBAR TO THE POOL BONDING WIRE OR THE POOL STEEL 5. REBAR TO BE ELEVATED TO THE CENTER OF THE POOL DECK POUR 6. THIS IS FOR ALL POOL DECK POURS FOR NOW ON 7. WHEN 3' ISN'T AVAILABLE THEN RUN THE REBAR ABOVE THE OUTSIDE PERIMETER EDGE REBAR MAINTAINING 2" FROM THE OUTSIDE FORM AND STILL ELEVATED TO THE CENTER OF THE DECK POUR. 9. NO FEE | |||
| STEEL & GROUND | 01/29/2007 | APPROVED | ACOOPER |
| Note: THIS IS A REINSPECTION | |||
| STEEL & GROUND | 01/22/2007 | CANCELLED BY APPLICANT | MMOORE |
| POOL - FINAL | |||
| STORMWATER FINAL INSPECTION | |||
| Note: THIS IS A REINSPECTION |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/10/2007 | 01/11/2007 |
| Note: Released By: CCOTE Approved for Release. Review by Auba. | |||
| SW1 | COMPLETE | 01/08/2007 | 01/09/2007 |
| Note: Released By: WKINELL | |||
| ZON | COMPLETE | 01/04/2007 | 01/08/2007 |
| Note: Released By: DRAMIREZ |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ARC POOL/SCREEN REVIEW | ¤50.00 | 01/12/2007 |
| ELECTRIC FEE | ¤54.00 | 01/12/2007 |
| PERMIT FEE | ¤240.00 | 01/12/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/12/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | |
| Fees | Total Due: ¤35.00 | Total Paid: ¤424.00 |