Permit #2007010134
Permit Details
Status: COED
| Parcel Id: 07-11-31-7031-00170-0030 |
| CONDITIONED SPACE: 1840 sqft |
| GARAGE: 397 sqft |
| OPENED PORCH (WITH ROOF) : 190 sqft |
| OPENED PORCH (WITH ROOF) : 63 sqft |
| Total Square Footage: 2490 sqft |
| Block: 00170 |
| Subdivision: - |
| Job Phone: (386)423-6670 |
| Location Address: 14 RIDDLE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/22/2007 |
| NOC: RECORDED |
| Applicant name: ADAM M BEATY |
| Owner: HARWOOD DONNA |
|
Address 12 CLEMENT COURT HAVERHILL, MA 01832 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤179,796.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
AFFORDABLE FLORIDA HOMES, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
4070 MONZA DRIVE NEW SMYRNA BEACH, FL 32168 |
CRC1328621 (Exp: 09/30/2008) | (386)423-6670 | (866)721-6888 |
Sub Contractors
RICHARD R EDWARDS
| Status | Location Address | State License Number | Phone |
| CANCEL |
P. O. Box 1637 Bunnell, FL 32110 |
ER0011603 (Exp: 08/31/2022) | (386) 437-1537 |
SINCLAIR W STICKLE
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
15 HARGROVE GRADE BLD 2 UNIT G PALM COAST, FL 32137 |
CAC052428 (Exp: 08/31/2018) | 386-446-1114 | (386)446-1278 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
GREGORY THOMAS BEATY
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
4070 MONZA DRIVE NEW SMYRNA BEACH, FL 32168 |
CCC1326955 (Exp: 08/31/2010) | (386)423-6670 | (866)721-6888 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 07/26/2007 | FINAL APPROVED | JHINDMAN |
| Note: Requested by Adam | |||
| FINAL COMPLETE BUILDING INSPECTION | 07/25/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: NEED ARC SHIELDS ON MIRROR RECEPTICLES, OPEN JACUZZI ACCESS FOR INSPECTION | |||
| STORMWATER FINAL INSPECTION | 07/24/2007 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| FINAL - PARTIAL | 07/17/2007 | Disapproved - NO FEE | JHINDMAN |
| Note: CALLED IN IN ERROR | |||
| RESIDENTIAL EARLY POWER | 07/17/2007 | APPROVED | JHINDMAN |
| ELECTRICAL FINAL | 07/17/2007 | Disapproved - NO FEE | JHINDMAN |
| Note: scheduled in error | |||
| STORMWATER FINAL INSPECTION | 07/16/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: DRAINAGE . RIGHT SIDE , DID TALK TO BUILDER 3:01 PM. MIKE . B | |||
| UTILITY COMPANY FINAL | 07/13/2007 | APPROVED | MBACON |
| Note: per request of Adam | |||
| DRIVEWAY | 06/15/2007 | APPROVED | GLALIMA |
| Note: passed on my way home june 14 , 2007 | |||
| DRIVEWAY | 06/13/2007 | CANCELLED BY INSPECTOR | GLALIMA |
| Note: THIS IS A REINSPECTION CANCELLED , DAMAGE FORMS / SEE GARY LALIMA . 931-0208 | |||
| DRIVEWAY | 06/12/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: NEED TO HAVE A 90 deg/ CUT AT ROAD AND 5 '' MIN OF CONCRETE OVER CULVERT PIPE , AND AT STREET. | |||
| INSULATION INSPECTION | 05/03/2007 | APPROVED | JHINDMAN |
| Note: CALLED BY ADAM | |||
| ALL ROUGH | 05/01/2007 | APPROVED - AS NOTED | JMCGOWEN |
| Note: NEED TO FIREBLOCK AT FRONT ENTRANCE.......HAVE REPAIR LETTER FROM CITY FOR TRUSS BY INSULATION... | |||
| LATH /BRICK FLASHING | 04/25/2007 | APPROVED | JHINDMAN |
| Note: | |||
| ALL ROUGH | 04/24/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: CALLED BY ADAM NEED TO GET LETTER OF REPAIR FOR TRUSS T-24 CRACKED AT BOTTOM CORD....DROP CEILING FIRE BLOCK NEEDS TO BE SOLID TO CONCRETE WALL...NAIL PLATES NEEDED AT BLOCK AT MASTER TUB.... CHARLIE.....931-1251 | |||
| INSULATION INSPECTION | 04/23/2007 | Disapproved - NO FEE | JHINDMAN |
| Note: ALL ROUGH HAS NOT PASSED | |||
| ALL ROUGH | 04/17/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: per adam request NEED SOLID BLOCKING AT ALL DROP CEILING WHERE 1X4S ARE USED AGAINST TUFF-R INSULATION....NEED TO MOVE SWITCHES FROM INSIDE EDGE OF MASTER TUB.....NEED TO TIE GROUNDS TOGETHER AT KITCHEN BOX....NEED TO SUPPORT WIRES HANGING DOWN BELOW CEILING LINE IN BATH.... | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 03/27/2007 | APPROVED | PGALLMANN |
| Note: per request of Adam | |||
| LINTEL | 03/12/2007 | APPROVED | PGALLMANN |
| Note: | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 03/08/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 02/26/2007 | APPROVED | JHINDMAN |
| Note: | |||
| MONOLITHIC SLAB INSPECTION/SLAB | 02/23/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: YOU NEED THE APPROVED PLANS FOR INSPECTION | |||
| FIRST ROUGH PLUMBING INSPECTION | 02/13/2007 | APPROVED | JHINDMAN |
| Note: |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 05/25/2007 | 05/25/2007 |
| Note: Released By: LAPTEKAR received revised topo survey | |||
| SW1 | HOLD | 05/15/2007 | 05/15/2007 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are higher than we expected by 0.34ft. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised. | |||
| BLD | COMPLETE | 04/30/2007 | 05/01/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Truss Repair T24. | |||
| BLD | COMPLETE | 01/12/2007 | 01/12/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| BLD | HOLD | 01/09/2007 | 01/09/2007 |
| Note: Held By: JJOSEPH 1-The 2006 supplement to the Florida Building Code is effective since December 8, 2006 and shall be complied to the following requirements: a- The Energy form 600A-2004 is no longer acceptable; please provide the new Energy form ( 600A-04R) and the correcte jurisdiction number using the compuer program FLA-RES-04 version 4.5. b- As mentionned in section F (sheet 2 of 5); cementitious coating can not be used over concrete block (exterior masonry walls ),unless the block can be shown to be non-porous. Please change it to the Stucco to meet the code requirement. 2- Provide the lintel schedule 3-Provide the electrical plan | |||
| SW1 | COMPLETE | 01/09/2007 | 01/09/2007 |
| Note: Released By: LAPTEKAR | |||
| ZON | COMPLETE | 01/08/2007 | 01/09/2007 |
| Note: Released By: DRAMIREZ |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 07/30/2007 |
| REINSPECTION FEE | ¤40.00 | 07/30/2007 |
| REINSPECTION FEE | ¤40.00 | 07/30/2007 |
| REINSPECTION FEE | ¤40.00 | 07/30/2007 |
| REINSPECTION FEE | ¤40.00 | 07/30/2007 |
| REVISION | ¤40.00 | 07/30/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 07/30/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 07/30/2007 |
| SW REVISION | ¤40.00 | 07/30/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 01/22/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 01/22/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/22/2007 |
| ADMIN FEE | ¤20.00 | 01/22/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 01/22/2007 |
| BUILDING CODE ADMIN FUND | ¤12.45 | 01/22/2007 |
| ELECTRIC FEE | ¤138.00 | 01/22/2007 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 01/22/2007 |
| MECHANICAL FEE | ¤138.00 | 01/22/2007 |
| PERMIT FEE | ¤702.00 | 01/22/2007 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 01/22/2007 |
| PLAN CHECK FEE | ¤72.00 | 01/22/2007 |
| PLUMBING FEE | ¤138.00 | 01/22/2007 |
| RADON FEE | ¤12.45 | 01/22/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,358.12 |