Permit #2007020186

Permit Details

Status: COED

Parcel Id: 07-11-31-7063-00450-0050
CONDITIONED SPACE: 1908 sqft
GARAGE: 464 sqft
SCREEN PORCH (SOLID ROOF) : 250 sqft
OPENED PORCH (WITH ROOF) : 165 sqft
Total Square Footage: 2787 sqft
Block: 00450
Subdivision: -
Job Phone: (386)775-4137
Location Address: 44 ZAUN TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/29/2007
NOC: RECORDED
Applicant name: JOHN THOMAS GARVER II
Owner: MASTERPIECE HOMES

Address

44 ZAUN TRAIL

PALM COAST, FL 32164

Lot: 0050
Contracted Stated Job Value: ¤136,015.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MASTERPIECE HOMES, INC.
Status Location Address State License Number Phone Fax
CANCEL

300 TREEMONTE DRIVE

ORANGE CITY, FL 32763

CGC1511952 (Exp: 08/31/2010) (386)775-4137 (386)775-1397

Sub Contractors

GLEN STEWART COLE
Status Location Address State License Number Phone Fax
HOLD

P. O. Box 1677

Palm Coast, FL 32136

EC0002522 (Exp: 08/31/2010) (386) 437-4364 (386)437-0412
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
JEFFREY JAY MITCHELL
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353178

PALM COAST, FL 32135

CCC1327078 (Exp: 08/31/2010) (386)437-3929 (386)447-2236
EDWARD DOUGLAS TENNANT
Status Location Address State License Number Phone Fax
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

ST. AUGUSTINE , FL 32092

CAC1813372 (Exp: 08/31/2026) (904)829-8898 (904)829-6587

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 07/12/2007 FINAL APPROVED DROCKWELL
STORMWATER FINAL INSPECTION 07/11/2007 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 07/06/2007 Disapproved -FEE REQUIRED GLALIMA
UTILITY COMPANY FINAL 07/03/2007 APPROVED TSCHWEERS
DRIVEWAY 06/22/2007 APPROVED - AS NOTED GLALIMA
Note: CLEAN OUT LEFT CORNER OF DRIVEWAY AND ROAD , SEE PAINT .
INSULATION INSPECTION 05/29/2007 APPROVED - AS NOTED DROCKWELL
Note: PLANS SHOW PRIVACY DOOR TO BED#2.AIR RETURN IS SITUATED DIRECTLY ABOVE SAID WALL IF INSTALLED.FYI
LATH /BRICK FLASHING 05/25/2007 APPROVED DROCKWELL
Note:
ALL ROUGH 05/24/2007 APPROVED JMCGOWEN
Note:
ALL ROUGH 05/23/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: NEED TO NAIL EXTERIOR WALL SHEATHING AT FRONT PORCH AND STRAP STUDS TO TOP AND BOTTOM PLATE,ALSO ANCHOR FOR IT IS AN EXTERIOR WALL.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 05/22/2007 APPROVED - AS NOTED DROCKWELL
Note: WALL SHEATHING AT FRONT PORCH NOT NAILED-OFF.DO NOT INSTALL WIRE LATH UNTIL AFTER THIS INSPECTION HAS BEEN APPROVED(FYI)WILL CHECK AT ALL ROUGH.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 05/21/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: NOT READY,ITEMS FROM LAST INSPECTION NOT COMPLETE.
ALL ROUGH 05/21/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: THIS INSPECTION SHOULD NOT BE CALLED IN UNTIL ROOF SHEATHING IS PASSED.
ALL ROUGH 05/18/2007 Disapproved - NO FEE JMCGOWEN
Note: ROOF SHEATHING HAS A HIGHER PRIORITY THAN ALL ROUGH, YOU MUST PASS SHEATHING FIRST.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 05/18/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: LOOSE SHEETS OVER BACK SLIDER,NEED TO BLOCK AND NAIL ALSO WHERE SHEATHING STOPS.....NEED TO REMOVE PAPER TO EXPOSE 2X12 HEADES ACROSS BACK PORCH.....NEED TO STRAP AND BOLT ENTIRE KNEE WALL ACROSS FRONT LINTEL AND REMOVE PAPER TO EXPOSE NAILING PATTERN.....
LINTEL 05/01/2007 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
LINTEL 04/30/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: Dowel work not complete
FOUNDATION SURVEY APPROVED BY STORMWATER 04/27/2007 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 04/20/2007 APPROVED PGALLMANN
FIRST ROUGH PLUMBING INSPECTION 04/19/2007 APPROVED DROCKWELL
Note:

Review History

Department Status Date In Date Out
SW1 COMPLETE 03/22/2007 03/23/2007
Note: Released By: LAPTEKAR received revised driveway detail plan
SW1 HOLD 03/14/2007 03/14/2007
Note: Held By: LAPTEKAR Driveway detail should not be city sample, please use driveway detail Masterpiece used on previous permits or incorporate company logo and modify city sample.
BLD COMPLETE 03/13/2007 03/14/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
BLD HOLD 02/28/2007 03/02/2007
Note: Held By: JJOSEPH 1. Exterior Finish. Indicate how the finish over wood framed walls will be provided and installed to comply with the Florida Building Code 2005 Supplement Section “R703.11 Weather Protection”. All wall surfaces that are not masonry or concrete shall be provided with weather protection per one of the approved building materials listed in Florida Building Code 2005 Supplement Table R703.11. Stucco, as indicated on the drawings, is acceptable if applied per ASTM C926 and the following criteria: i. Exterior Stucco shall be installed to prevent bonding to water resistive barrier per FRC, Section R703.2.1. ii. Exterior stucco shall be installed per ASTM C926; 3 coats with a minimum thickness of 7/8-inch per FRC, Section R703.6 & Table R703.11. iii. Installation of exterior lathing shall be installed to meet the requirements of ASTM C1063 per FRC, Section R703.6.2. The drawings indicate a cementituous coating. The Florida Building Code 2006 supplement section 1403.2 was modified to state “…that a weather-resistant exterior wall envelope shall not be required over concrete or non-porous masonry walls…” This means that, decorative cementituous coating CAN NOT, be used over exterior concrete or masonry walls, unless the they can be shown to be non-porous. Based on this information the drawings need to be revised to list one of the approved wall coverings per section R703.11 or testing must be provided showing that wall construction is non-porous. Stucco or Exterior Cement Portland Plaster are the acceptable terms from this code section.
ZON COMPLETE 02/28/2007 02/28/2007
Note: Released By: JGONZALEZ
ZON HOLD 02/08/2007 02/12/2007
Note: Held By: JGONZALEZ Need plant schedule and survey showing landscaping

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 07/16/2007
REINSPECTION FEE ¤40.00 07/16/2007
REINSPECTION FEE ¤40.00 07/16/2007
REINSPECTION FEE ¤40.00 07/16/2007
REINSPECTION FEE ¤40.00 07/16/2007
STORMWATER REINSPECTION FEE ¤35.00 07/16/2007
ADDITIONAL FEE ¤40.00 05/17/2007
ADMIN FEE ¤20.00 03/29/2007
ARC HOUSE REVIEW ¤125.00 03/29/2007
BUILDING CODE ADMIN FUND ¤13.94 03/29/2007
ELECTRIC FEE ¤145.80 03/29/2007
FIRE IMPACT FEE 4-1-06 ¤179.37 03/29/2007
MECHANICAL FEE ¤145.80 03/29/2007
PERMIT FEE ¤752.70 03/29/2007
PARKS IMPACT FEE 4/1/06 ¤1,159.02 03/29/2007
PLAN CHECK FEE ¤77.20 03/29/2007
PLUMBING FEE ¤145.80 03/29/2007
RADON FEE ¤13.94 03/29/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 03/29/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 03/29/2007
STORM WATER PERMIT FEES ¤80.00 03/29/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,365.40