Permit #2007020186
Permit Details
Status: COED
| Parcel Id: 07-11-31-7063-00450-0050 |
| CONDITIONED SPACE: 1908 sqft |
| GARAGE: 464 sqft |
| SCREEN PORCH (SOLID ROOF) : 250 sqft |
| OPENED PORCH (WITH ROOF) : 165 sqft |
| Total Square Footage: 2787 sqft |
| Block: 00450 |
| Subdivision: - |
| Job Phone: (386)775-4137 |
| Location Address: 44 ZAUN TR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/29/2007 |
| NOC: RECORDED |
| Applicant name: JOHN THOMAS GARVER II |
| Owner: MASTERPIECE HOMES |
|
Address 44 ZAUN TRAIL PALM COAST, FL 32164 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤136,015.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MASTERPIECE HOMES, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
300 TREEMONTE DRIVE ORANGE CITY, FL 32763 |
CGC1511952 (Exp: 08/31/2010) | (386)775-4137 | (386)775-1397 |
Sub Contractors
GLEN STEWART COLE
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
P. O. Box 1677 Palm Coast, FL 32136 |
EC0002522 (Exp: 08/31/2010) | (386) 437-4364 | (386)437-0412 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
JEFFREY JAY MITCHELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 353178 PALM COAST, FL 32135 |
CCC1327078 (Exp: 08/31/2010) | (386)437-3929 | (386)447-2236 |
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 07/12/2007 | FINAL APPROVED | DROCKWELL |
| STORMWATER FINAL INSPECTION | 07/11/2007 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 07/06/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| UTILITY COMPANY FINAL | 07/03/2007 | APPROVED | TSCHWEERS |
| DRIVEWAY | 06/22/2007 | APPROVED - AS NOTED | GLALIMA |
| Note: CLEAN OUT LEFT CORNER OF DRIVEWAY AND ROAD , SEE PAINT . | |||
| INSULATION INSPECTION | 05/29/2007 | APPROVED - AS NOTED | DROCKWELL |
| Note: PLANS SHOW PRIVACY DOOR TO BED#2.AIR RETURN IS SITUATED DIRECTLY ABOVE SAID WALL IF INSTALLED.FYI | |||
| LATH /BRICK FLASHING | 05/25/2007 | APPROVED | DROCKWELL |
| Note: | |||
| ALL ROUGH | 05/24/2007 | APPROVED | JMCGOWEN |
| Note: | |||
| ALL ROUGH | 05/23/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NEED TO NAIL EXTERIOR WALL SHEATHING AT FRONT PORCH AND STRAP STUDS TO TOP AND BOTTOM PLATE,ALSO ANCHOR FOR IT IS AN EXTERIOR WALL. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/22/2007 | APPROVED - AS NOTED | DROCKWELL |
| Note: WALL SHEATHING AT FRONT PORCH NOT NAILED-OFF.DO NOT INSTALL WIRE LATH UNTIL AFTER THIS INSPECTION HAS BEEN APPROVED(FYI)WILL CHECK AT ALL ROUGH. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/21/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NOT READY,ITEMS FROM LAST INSPECTION NOT COMPLETE. | |||
| ALL ROUGH | 05/21/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: THIS INSPECTION SHOULD NOT BE CALLED IN UNTIL ROOF SHEATHING IS PASSED. | |||
| ALL ROUGH | 05/18/2007 | Disapproved - NO FEE | JMCGOWEN |
| Note: ROOF SHEATHING HAS A HIGHER PRIORITY THAN ALL ROUGH, YOU MUST PASS SHEATHING FIRST. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/18/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: LOOSE SHEETS OVER BACK SLIDER,NEED TO BLOCK AND NAIL ALSO WHERE SHEATHING STOPS.....NEED TO REMOVE PAPER TO EXPOSE 2X12 HEADES ACROSS BACK PORCH.....NEED TO STRAP AND BOLT ENTIRE KNEE WALL ACROSS FRONT LINTEL AND REMOVE PAPER TO EXPOSE NAILING PATTERN..... | |||
| LINTEL | 05/01/2007 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| LINTEL | 04/30/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Dowel work not complete | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 04/27/2007 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 04/20/2007 | APPROVED | PGALLMANN |
| FIRST ROUGH PLUMBING INSPECTION | 04/19/2007 | APPROVED | DROCKWELL |
| Note: |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 03/22/2007 | 03/23/2007 |
| Note: Released By: LAPTEKAR received revised driveway detail plan | |||
| SW1 | HOLD | 03/14/2007 | 03/14/2007 |
| Note: Held By: LAPTEKAR Driveway detail should not be city sample, please use driveway detail Masterpiece used on previous permits or incorporate company logo and modify city sample. | |||
| BLD | COMPLETE | 03/13/2007 | 03/14/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| BLD | HOLD | 02/28/2007 | 03/02/2007 |
| Note: Held By: JJOSEPH 1. Exterior Finish. Indicate how the finish over wood framed walls will be provided and installed to comply with the Florida Building Code 2005 Supplement Section “R703.11 Weather Protection”. All wall surfaces that are not masonry or concrete shall be provided with weather protection per one of the approved building materials listed in Florida Building Code 2005 Supplement Table R703.11. Stucco, as indicated on the drawings, is acceptable if applied per ASTM C926 and the following criteria: i. Exterior Stucco shall be installed to prevent bonding to water resistive barrier per FRC, Section R703.2.1. ii. Exterior stucco shall be installed per ASTM C926; 3 coats with a minimum thickness of 7/8-inch per FRC, Section R703.6 & Table R703.11. iii. Installation of exterior lathing shall be installed to meet the requirements of ASTM C1063 per FRC, Section R703.6.2. The drawings indicate a cementituous coating. The Florida Building Code 2006 supplement section 1403.2 was modified to state “…that a weather-resistant exterior wall envelope shall not be required over concrete or non-porous masonry walls…” This means that, decorative cementituous coating CAN NOT, be used over exterior concrete or masonry walls, unless the they can be shown to be non-porous. Based on this information the drawings need to be revised to list one of the approved wall coverings per section R703.11 or testing must be provided showing that wall construction is non-porous. Stucco or Exterior Cement Portland Plaster are the acceptable terms from this code section. | |||
| ZON | COMPLETE | 02/28/2007 | 02/28/2007 |
| Note: Released By: JGONZALEZ | |||
| ZON | HOLD | 02/08/2007 | 02/12/2007 |
| Note: Held By: JGONZALEZ Need plant schedule and survey showing landscaping |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/16/2007 |
| REINSPECTION FEE | ¤40.00 | 07/16/2007 |
| REINSPECTION FEE | ¤40.00 | 07/16/2007 |
| REINSPECTION FEE | ¤40.00 | 07/16/2007 |
| REINSPECTION FEE | ¤40.00 | 07/16/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 07/16/2007 |
| ADDITIONAL FEE | ¤40.00 | 05/17/2007 |
| ADMIN FEE | ¤20.00 | 03/29/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 03/29/2007 |
| BUILDING CODE ADMIN FUND | ¤13.94 | 03/29/2007 |
| ELECTRIC FEE | ¤145.80 | 03/29/2007 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 03/29/2007 |
| MECHANICAL FEE | ¤145.80 | 03/29/2007 |
| PERMIT FEE | ¤752.70 | 03/29/2007 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 03/29/2007 |
| PLAN CHECK FEE | ¤77.20 | 03/29/2007 |
| PLUMBING FEE | ¤145.80 | 03/29/2007 |
| RADON FEE | ¤13.94 | 03/29/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 03/29/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/29/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/29/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,365.40 |