Permit #2007020272

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00220-0090
CONDITIONED SPACE: 2431 sqft
GARAGE: 444 sqft
SCREEN PORCH (SOLID ROOF) : 240 sqft
OPENED PORCH (WITH ROOF) : 25 sqft
Total Square Footage: 3140 sqft
Block: 00220
Subdivision: -
Job Phone: (386)775-4137
Location Address: 17 ROYAL LEAF LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/16/2007
NOC: RECORDED
Applicant name: JOHN THOMAS GARVER II
Owner: MASTERPIECE HOMES INC

Address

4721 E MOODY BLVD

BUNNELL, FL 32110

Lot: 0090
Contracted Stated Job Value: ¤142,315.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MASTERPIECE HOMES, INC.
Status Location Address State License Number Phone Fax
CANCEL

300 TREEMONTE DRIVE

ORANGE CITY, FL 32763

CGC1511952 (Exp: 08/31/2010) (386)775-4137 (386)775-1397

Sub Contractors

GLEN STEWART COLE
Status Location Address State License Number Phone Fax
HOLD

P. O. Box 1677

Palm Coast, FL 32136

EC0002522 (Exp: 08/31/2010) (386) 437-4364 (386)437-0412
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
JEFFREY JAY MITCHELL
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353178

PALM COAST, FL 32135

CCC1327078 (Exp: 08/31/2010) (386)437-3929 (386)447-2236
EDWARD DOUGLAS TENNANT
Status Location Address State License Number Phone Fax
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

ST. AUGUSTINE , FL 32092

CAC1813372 (Exp: 08/31/2026) (904)829-8898 (904)829-6587

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 06/19/2007 FINAL APPROVED JHINDMAN
Note: THIS IS A REINSPECTION no power on house for hot check
FINAL COMPLETE BUILDING INSPECTION 06/18/2007 Disapproved -FEE REQUIRED JHINDMAN
Note: ahu label does not match breaker, disposer is not wired up
UTILITY COMPANY FINAL 06/15/2007 APPROVED PLAWRENCE
STORMWATER FINAL INSPECTION 06/08/2007 APPROVED GLALIMA
DRIVEWAY 05/14/2007 APPROVED GLALIMA
INSULATION INSPECTION 04/26/2007 APPROVED JHINDMAN
Note:
LATH /BRICK FLASHING 04/26/2007 APPROVED JHINDMAN
Note:
ALL ROUGH 04/24/2007 APPROVED PGALLMANN
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/18/2007 APPROVED PGALLMANN
Note: THIS IS A REINSPECTION
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/17/2007 Disapproved - NO FEE PGALLMANN
Note: INADEQUATE BEARING OF PORCH HEADERS AT OUTSIDE CORNERS.
EXTERIOR WALL SHEATHING/SHEAR WALL 04/09/2007 APPROVED DROCKWELL
Note:
LINTEL 04/03/2007 APPROVED RMARVEL
Note:
FOUNDATION SURVEY APPROVED BY STORMWATER 04/02/2007 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 03/27/2007 APPROVED JHINDMAN
Note:
FIRST ROUGH PLUMBING INSPECTION 03/23/2007 APPROVED JHINDMAN
Note:

Review History

Department Status Date In Date Out
BLD COMPLETE 03/13/2007 03/15/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
ZON COMPLETE 02/28/2007 02/28/2007
Note: Released By: JGONZALEZ
BLD HOLD 02/28/2007 03/05/2007
Note: Held By: JJOSEPH 1. Exterior Finish. Indicate how the finish over wood framed walls will be provided and installed to comply with the Florida Building Code 2005 Supplement Section “R703.11 Weather Protection”. All wall surfaces that are not masonry or concrete shall be provided with weather protection per one of the approved building materials listed in Florida Building Code 2005 Supplement Table R703.11. Stucco, as indicated on the drawings, is acceptable if applied per ASTM C926 and the following criteria: i. Exterior Stucco shall be installed to prevent bonding to water resistive barrier per FRC, Section R703.2.1. ii. Exterior stucco shall be installed per ASTM C926; 3 coats with a minimum thickness of 7/8-inch per FRC, Section R703.6 & Table R703.11. iii. Installation of exterior lathing shall be installed to meet the requirements of ASTM C1063 per FRC, Section R703.6.2. The drawings indicate a cementituous coating. The Florida Building Code 2006 supplement section 1403.2 was modified to state “…that a weather-resistant exterior wall envelope shall not be required over concrete or non-porous masonry walls…” This means that, decorative cementituous coating CAN NOT, be used over exterior concrete or masonry walls, unless the they can be shown to be non-porous. Based on this information the drawings need to be revised to list one of the approved wall coverings per section R703.11 or testing must be provided showing that wall construction is non-porous. Stucco or Exterior Cement Portland Plaster are the acceptable terms from this code section.
SW1 COMPLETE 02/12/2007 02/13/2007
Note: Released By: LAPTEKAR may consider common property line swales with neighboring improved lots
ZON HOLD 02/12/2007 02/14/2007
Note: Held By: JGONZALEZ need a landscaping plan with a plant schedule attached Please make sure landscaping on front and rear of property

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/27/2007
ADDITIONAL FEE ¤40.00 05/17/2007
ADMIN FEE ¤20.00 03/16/2007
ARC HOUSE REVIEW ¤125.00 03/16/2007
BUILDING CODE ADMIN FUND ¤15.70 03/16/2007
ELECTRIC FEE ¤169.80 03/16/2007
FIRE IMPACT FEE 4-1-06 ¤179.37 03/16/2007
MECHANICAL FEE ¤169.80 03/16/2007
PERMIT FEE ¤908.70 03/16/2007
PARKS IMPACT FEE 4/1/06 ¤1,159.02 03/16/2007
PLAN CHECK FEE ¤93.20 03/16/2007
PLUMBING FEE ¤169.80 03/16/2007
RADON FEE ¤15.70 03/16/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 03/16/2007
STORM WATER PERMIT FEES ¤80.00 03/16/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 03/16/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,417.92