Permit #2007020274

Permit Details

Status: COED

Parcel Id: 07-11-31-7063-00630-0040
CONDITIONED SPACE: 2028 sqft
GARAGE: 446 sqft
SCREEN PORCH (SOLID ROOF) : 200 sqft
OPENED PORCH (WITH ROOF) : 48 sqft
Total Square Footage: 2722 sqft
Block: 00630
Subdivision: -
Job Phone: (386)775-4137
Location Address: 11 ZEPHYR LILY PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/16/2007
NOC: RECORDED
Applicant name: JOHN THOMAS GARVER II
Owner: MASTERPIECE HOMES INC

Address

4721 E MOODY BLVD

BUNNELL, FL 32110

Lot: 0040
Contracted Stated Job Value: ¤124,531.00
Job Description: SINGLE FAMILY
Type: CN

Contractor

MASTERPIECE HOMES, INC.
Status Location Address State License Number Phone Fax
CANCEL

300 TREEMONTE DRIVE

ORANGE CITY, FL 32763

CGC1511952 (Exp: 08/31/2010) (386)775-4137 (386)775-1397

Sub Contractors

GLEN STEWART COLE
Status Location Address State License Number Phone Fax
HOLD

P. O. Box 1677

Palm Coast, FL 32136

EC0002522 (Exp: 08/31/2010) (386) 437-4364 (386)437-0412
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
JEFFREY JAY MITCHELL
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353178

PALM COAST, FL 32135

CCC1327078 (Exp: 08/31/2010) (386)437-3929 (386)447-2236
EDWARD DOUGLAS TENNANT
Status Location Address State License Number Phone Fax
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

ST. AUGUSTINE , FL 32092

CAC1813372 (Exp: 08/31/2026) (904)829-8898 (904)829-6587

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 06/22/2007 FINAL APPROVED JGIBSON
Note: UNABLE TO HOT CHECK HOUSE.
STORMWATER FINAL INSPECTION 06/15/2007 APPROVED GLALIMA
UTILITY COMPANY FINAL 06/15/2007 APPROVED MBACON
DRIVEWAY 05/24/2007 APPROVED DRANDALL
INSULATION INSPECTION 04/27/2007 APPROVED DROCKWELL
Note:
LATH /BRICK FLASHING 04/27/2007 APPROVED DROCKWELL
Note:
ALL ROUGH 04/26/2007 APPROVED JMCGOWEN
Note: THIS IS A REINSPECTION
ALL ROUGH 04/25/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: NEED TO REPLACE BOX AT SLIDER WITH BIGGER CU.IN.... TUB WALL NEEDS SOLE PLATE.. NEED TO CAP OFF UNUSED N.M.T AT PANEL.
ALL ROUGH 04/24/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: NEED TO COMPLETE CARRIGE LIGHT ROUGH IN....WIRES AT ATTIC ACCESS NEEDS TO BE 6` AWAY FROM HOLE....NAIL PLATES AND BLOCKING NEEDED AT TUB WALL AND AT KITCHEN ISLAND WALL....OVER FILL AT BOX NEXT TO SLIDER DOOR.....SERVICE CABLE IN MASTER NEEDS TO BE SUPPORTED EVERY 4-1/2`
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/17/2007 APPROVED DROCKWELL
Note: called by Steve
LINTEL 04/04/2007 APPROVED PGALLMANN
Note:
FOUNDATION SURVEY APPROVED BY STORMWATER 04/02/2007 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 03/28/2007 APPROVED DROCKWELL
Note:
FIRST ROUGH PLUMBING INSPECTION 03/23/2007 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
BLD COMPLETE 03/13/2007 03/15/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
BLD HOLD 02/28/2007 03/05/2007
Note: Held By: JJOSEPH 1. Exterior Finish. Indicate how the finish over wood framed walls will be provided and installed to comply with the Florida Building Code 2005 Supplement Section “R703.11 Weather Protection”. All wall surfaces that are not masonry or concrete shall be provided with weather protection per one of the approved building materials listed in Florida Building Code 2005 Supplement Table R703.11. Stucco, as indicated on the drawings, is acceptable if applied per ASTM C926 and the following criteria: i. Exterior Stucco shall be installed to prevent bonding to water resistive barrier per FRC, Section R703.2.1. ii. Exterior stucco shall be installed per ASTM C926; 3 coats with a minimum thickness of 7/8-inch per FRC, Section R703.6 & Table R703.11. iii. Installation of exterior lathing shall be installed to meet the requirements of ASTM C1063 per FRC, Section R703.6.2. The drawings indicate a cementituous coating. The Florida Building Code 2006 supplement section 1403.2 was modified to state “…that a weather-resistant exterior wall envelope shall not be required over concrete or non-porous masonry walls…” This means that, decorative cementituous coating CAN NOT, be used over exterior concrete or masonry walls, unless the they can be shown to be non-porous. Based on this information the drawings need to be revised to list one of the approved wall coverings per section R703.11 or testing must be provided showing that wall construction is non-porous. Stucco or Exterior Cement Portland Plaster are the acceptable terms from this code section.
ZON COMPLETE 02/28/2007 02/28/2007
Note: Released By: JGONZALEZ
ZON HOLD 02/12/2007 02/15/2007
Note: Held By: JGONZALEZ need survey showing landscaping in front and rear of property include plant schedule
SW1 COMPLETE 02/13/2007
Note: Released By: WKINELL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/27/2007
REINSPECTION FEE ¤40.00 06/27/2007
ADDITIONAL FEE ¤40.00 05/17/2007
ADMIN FEE ¤20.00 03/16/2007
ARC HOUSE REVIEW ¤125.00 03/16/2007
BUILDING CODE ADMIN FUND ¤13.61 03/16/2007
ELECTRIC FEE ¤148.80 03/16/2007
FIRE IMPACT FEE 4-1-06 ¤179.37 03/16/2007
MECHANICAL FEE ¤148.80 03/16/2007
PERMIT FEE ¤772.20 03/16/2007
PARKS IMPACT FEE 4/1/06 ¤1,159.02 03/16/2007
PLAN CHECK FEE ¤79.20 03/16/2007
PLUMBING FEE ¤148.80 03/16/2007
RADON FEE ¤13.61 03/16/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 03/16/2007
STORM WATER PERMIT FEES ¤80.00 03/16/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 03/16/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,240.24