Permit #2007020274
Permit Details
Status: COED
| Parcel Id: 07-11-31-7063-00630-0040 |
| CONDITIONED SPACE: 2028 sqft |
| GARAGE: 446 sqft |
| SCREEN PORCH (SOLID ROOF) : 200 sqft |
| OPENED PORCH (WITH ROOF) : 48 sqft |
| Total Square Footage: 2722 sqft |
| Block: 00630 |
| Subdivision: - |
| Job Phone: (386)775-4137 |
| Location Address: 11 ZEPHYR LILY PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/16/2007 |
| NOC: RECORDED |
| Applicant name: JOHN THOMAS GARVER II |
| Owner: MASTERPIECE HOMES INC |
|
Address 4721 E MOODY BLVD BUNNELL, FL 32110 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤124,531.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
MASTERPIECE HOMES, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
300 TREEMONTE DRIVE ORANGE CITY, FL 32763 |
CGC1511952 (Exp: 08/31/2010) | (386)775-4137 | (386)775-1397 |
Sub Contractors
GLEN STEWART COLE
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
P. O. Box 1677 Palm Coast, FL 32136 |
EC0002522 (Exp: 08/31/2010) | (386) 437-4364 | (386)437-0412 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
JEFFREY JAY MITCHELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 353178 PALM COAST, FL 32135 |
CCC1327078 (Exp: 08/31/2010) | (386)437-3929 | (386)447-2236 |
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 06/22/2007 | FINAL APPROVED | JGIBSON |
| Note: UNABLE TO HOT CHECK HOUSE. | |||
| STORMWATER FINAL INSPECTION | 06/15/2007 | APPROVED | GLALIMA |
| UTILITY COMPANY FINAL | 06/15/2007 | APPROVED | MBACON |
| DRIVEWAY | 05/24/2007 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 04/27/2007 | APPROVED | DROCKWELL |
| Note: | |||
| LATH /BRICK FLASHING | 04/27/2007 | APPROVED | DROCKWELL |
| Note: | |||
| ALL ROUGH | 04/26/2007 | APPROVED | JMCGOWEN |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 04/25/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NEED TO REPLACE BOX AT SLIDER WITH BIGGER CU.IN.... TUB WALL NEEDS SOLE PLATE.. NEED TO CAP OFF UNUSED N.M.T AT PANEL. | |||
| ALL ROUGH | 04/24/2007 | Disapproved -FEE REQUIRED | JMCGOWEN |
| Note: NEED TO COMPLETE CARRIGE LIGHT ROUGH IN....WIRES AT ATTIC ACCESS NEEDS TO BE 6` AWAY FROM HOLE....NAIL PLATES AND BLOCKING NEEDED AT TUB WALL AND AT KITCHEN ISLAND WALL....OVER FILL AT BOX NEXT TO SLIDER DOOR.....SERVICE CABLE IN MASTER NEEDS TO BE SUPPORTED EVERY 4-1/2` | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 04/17/2007 | APPROVED | DROCKWELL |
| Note: called by Steve | |||
| LINTEL | 04/04/2007 | APPROVED | PGALLMANN |
| Note: | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 04/02/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 03/28/2007 | APPROVED | DROCKWELL |
| Note: | |||
| FIRST ROUGH PLUMBING INSPECTION | 03/23/2007 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/13/2007 | 03/15/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| BLD | HOLD | 02/28/2007 | 03/05/2007 |
| Note: Held By: JJOSEPH 1. Exterior Finish. Indicate how the finish over wood framed walls will be provided and installed to comply with the Florida Building Code 2005 Supplement Section “R703.11 Weather Protection”. All wall surfaces that are not masonry or concrete shall be provided with weather protection per one of the approved building materials listed in Florida Building Code 2005 Supplement Table R703.11. Stucco, as indicated on the drawings, is acceptable if applied per ASTM C926 and the following criteria: i. Exterior Stucco shall be installed to prevent bonding to water resistive barrier per FRC, Section R703.2.1. ii. Exterior stucco shall be installed per ASTM C926; 3 coats with a minimum thickness of 7/8-inch per FRC, Section R703.6 & Table R703.11. iii. Installation of exterior lathing shall be installed to meet the requirements of ASTM C1063 per FRC, Section R703.6.2. The drawings indicate a cementituous coating. The Florida Building Code 2006 supplement section 1403.2 was modified to state “…that a weather-resistant exterior wall envelope shall not be required over concrete or non-porous masonry walls…” This means that, decorative cementituous coating CAN NOT, be used over exterior concrete or masonry walls, unless the they can be shown to be non-porous. Based on this information the drawings need to be revised to list one of the approved wall coverings per section R703.11 or testing must be provided showing that wall construction is non-porous. Stucco or Exterior Cement Portland Plaster are the acceptable terms from this code section. | |||
| ZON | COMPLETE | 02/28/2007 | 02/28/2007 |
| Note: Released By: JGONZALEZ | |||
| ZON | HOLD | 02/12/2007 | 02/15/2007 |
| Note: Held By: JGONZALEZ need survey showing landscaping in front and rear of property include plant schedule | |||
| SW1 | COMPLETE | 02/13/2007 | |
| Note: Released By: WKINELL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 06/27/2007 |
| REINSPECTION FEE | ¤40.00 | 06/27/2007 |
| ADDITIONAL FEE | ¤40.00 | 05/17/2007 |
| ADMIN FEE | ¤20.00 | 03/16/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 03/16/2007 |
| BUILDING CODE ADMIN FUND | ¤13.61 | 03/16/2007 |
| ELECTRIC FEE | ¤148.80 | 03/16/2007 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 03/16/2007 |
| MECHANICAL FEE | ¤148.80 | 03/16/2007 |
| PERMIT FEE | ¤772.20 | 03/16/2007 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 03/16/2007 |
| PLAN CHECK FEE | ¤79.20 | 03/16/2007 |
| PLUMBING FEE | ¤148.80 | 03/16/2007 |
| RADON FEE | ¤13.61 | 03/16/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/16/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/16/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 03/16/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,240.24 |