I want to search for...
Permit #2007020315
Permit Details
Status: COED
| Parcel Id: 07-11-31-7029-00560-0010 |
| CONDITIONED SPACE: 2282 sqft |
| GARAGE: 431 sqft |
| SCREEN PORCH (SOLID ROOF) : 240 sqft |
| OPENED PORCH (WITH ROOF) : 48 sqft |
| Total Square Footage: 3001 sqft |
| Block: 00560 |
| Subdivision: - |
| Job Phone: (386)775-4137 |
| Location Address: 54 RYARBOR DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/29/2007 |
| NOC: RECORDED |
| Applicant name: JOHN THOMAS GARVER II |
| Owner: MASTERPIECE HOMES INC |
|
Address 54 RYARBOR DRIVE PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤135,659.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MASTERPIECE HOMES, INC.
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
300 TREEMONTE DRIVE ORANGE CITY, FL 32763 |
CGC1511952 (Exp: 08/31/2010) | (386)775-4137 | (386)775-1397 |
Sub Contractors
GLEN STEWART COLE
| Status | Location Address | State License Number | Phone | Fax |
| HOLD |
P. O. Box 1677 Palm Coast, FL 32136 |
EC0002522 (Exp: 08/31/2010) | (386) 437-4364 | (386)437-0412 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
JEFFREY JAY MITCHELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 353178 PALM COAST, FL 32135 |
CCC1327078 (Exp: 08/31/2010) | (386)437-3929 | (386)447-2236 |
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 08/02/2007 | FINAL APPROVED | ACOOPER |
| FINAL COMPLETE BUILDING INSPECTION | 08/01/2007 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: ARC-FAULT BREAKER #13 IS INOPERABLE AND THERE ARE SEVERAL RECEPTICALS IN BONUS BEDROOM THAT ARE LIVE WHEN ARC-FAULTS ARE TURNED OFF. | |||
| UTILITY COMPANY FINAL | 07/26/2007 | APPROVED | MBACON |
| STORMWATER FINAL INSPECTION | 07/23/2007 | APPROVED | GLALIMA |
| DRIVEWAY | 07/05/2007 | APPROVED | GLALIMA |
| Note: BUILDER WAS TOLD TO RECHECK ELEVATION . | |||
| RESIDENTIAL EARLY POWER | 06/28/2007 | APPROVED | LHITES |
| Note: Steve called in inspection | |||
| INSULATION INSPECTION | 05/18/2007 | APPROVED | JHINDMAN |
| LATH /BRICK FLASHING | 05/16/2007 | APPROVED | DROCKWELL |
| ALL ROUGH | 05/16/2007 | APPROVED | DROCKWELL |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 05/04/2007 | APPROVED | PGALLMANN |
| EXTERIOR WALL SHEATHING/SHEAR WALL | 04/30/2007 | APPROVED | ACOOPER |
| Note: | |||
| LINTEL | 04/25/2007 | APPROVED | ACOOPER |
| Note: | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 04/24/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 04/17/2007 | APPROVED | PGALLMANN |
| FIRST ROUGH PLUMBING INSPECTION | 04/13/2007 | APPROVED | JHINDMAN |
| Note: |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 03/22/2007 | 03/23/2007 |
| Note: Released By: WKINELL Received Builders driveway detail.\\wk | |||
| SW1 | HOLD | 03/14/2007 | 03/14/2007 |
| Note: Held By: WKINELL Need original driveway detail sheet, not generic City copy. | |||
| BLD | COMPLETE | 03/13/2007 | 03/14/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| BLD | HOLD | 02/28/2007 | 03/05/2007 |
| Note: Held By: JJOSEPH 1. Exterior Finish. Indicate how the finish over wood framed walls will be provided and installed to comply with the Florida Building Code 2005 Supplement Section “R703.11 Weather Protection”. All wall surfaces that are not masonry or concrete shall be provided with weather protection per one of the approved building materials listed in Florida Building Code 2005 Supplement Table R703.11. Stucco, as indicated on the drawings, is acceptable if applied per ASTM C926 and the following criteria: i. Exterior Stucco shall be installed to prevent bonding to water resistive barrier per FRC, Section R703.2.1. ii. Exterior stucco shall be installed per ASTM C926; 3 coats with a minimum thickness of 7/8-inch per FRC, Section R703.6 & Table R703.11. iii. Installation of exterior lathing shall be installed to meet the requirements of ASTM C1063 per FRC, Section R703.6.2. The drawings indicate a cementituous coating. The Florida Building Code 2006 supplement section 1403.2 was modified to state “…that a weather-resistant exterior wall envelope shall not be required over concrete or non-porous masonry walls…” This means that, decorative cementituous coating CAN NOT, be used over exterior concrete or masonry walls, unless the they can be shown to be non-porous. Based on this information the drawings need to be revised to list one of the approved wall coverings per section R703.11 or testing must be provided showing that wall construction is non-porous. Stucco or Exterior Cement Portland Plaster are the acceptable terms from this code section. | |||
| ZON | COMPLETE | 02/28/2007 | 02/28/2007 |
| Note: Released By: JGONZALEZ | |||
| ZON | HOLD | 02/13/2007 | 02/15/2007 |
| Note: Held By: JGONZALEZ need survey showing landscaping in front and rear of home with plant schedule |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 08/03/2007 |
| REINSPECTION FEE | ¤40.00 | 08/03/2007 |
| ADDITIONAL FEE | ¤40.00 | 05/17/2007 |
| ADMIN FEE | ¤20.00 | 03/29/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 03/29/2007 |
| BUILDING CODE ADMIN FUND | ¤15.01 | 03/29/2007 |
| ELECTRIC FEE | ¤162.00 | 03/29/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/29/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/29/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 03/29/2007 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 03/29/2007 |
| MECHANICAL FEE | ¤162.00 | 03/29/2007 |
| PERMIT FEE | ¤858.00 | 03/29/2007 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 03/29/2007 |
| PLAN CHECK FEE | ¤88.00 | 03/29/2007 |
| PLUMBING FEE | ¤162.00 | 03/29/2007 |
| RADON FEE | ¤15.01 | 03/29/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,377.24 |