I want to search for...

Permit #2007020406

Permit Details

Status: COED

Parcel Id: 29-10-31-5540-01010-1280
CONDITIONED SPACE: 2700 sqft
GARAGE: 618 sqft
OPENED PORCH (WITH ROOF) : 316 sqft
OPENED PORCH (WITH ROOF) : 90 sqft
Total Square Footage: 3724 sqft
Block: 1010
Subdivision: 1005 - SANCTUARY
Job Phone: (386) 445-5239
Location Address: 9 SABAL BEND
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/07/2007
NOC: RECORDED
Applicant name: KEITH M PARKER
Owner: DILLARD CONSTRUCTION, LLC

Address

1 FLORIDA PARK DRIVE

PALM COAST, FL 32137

Address

# 108

PALM COAST, FL 32137

Lot: 1280
Contracted Stated Job Value: ¤210,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

DILLARD CONSTRUCTION LLC.
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 355007

PALM COAST, FL 32137

CGC1510399 (Exp: 09/30/2010) 386-864-1320 (386)986-3054

Sub Contractors

ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
MARTIN JOHN EVANS
Status Location Address State License Number
ACTIVE

14 FORT CAROLINE CT

BUNNELL, FL 32110

CFC057676 (Exp: 08/31/2026)
MILLARD K KELLER
Status Location Address State License Number Phone Fax
CANCEL

313 S. VOLUSIA AVENUE

DELAND, FL 32724

CCC1325778 (Exp: 08/31/2010) (386) 774-9961 (386)774-2388
BOB BELL
Status Location Address State License Number Phone Fax
CANCEL

20 UTILITY DRIVE

PALM COAST, FL 32137

13878 (Exp: 08/31/2012) (386)437-4404 (386)446-2191
TRENT MIHALIC
Status Location Address State License Number Phone Fax
CANCEL

P.O. BOX 606

ZELWOOD, FL 32798

EC0003150 (Exp: 08/31/2012) (321) 229-1241 (386)698-2956

Inspection History

Type Request Date Result Inspector
GAS FINAL 11/19/2007 APPROVED DROCKWELL
FINAL COMPLETE BUILDING INSPECTION 11/19/2007 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 11/16/2007 Disapproved -FEE REQUIRED DROCKWELL
Note: GAS WATER HEATER NOT COMPLETED.VACUME BREAKERS AT HOSE BIBBS AND LAUNDRY TUB.SEAL PENETRATIONS THRU GARAGE CEILING.INCOMPLETE INSPECTION.GAS FINAL NOT CALLED IN.
RESIDENTIAL EARLY POWER 11/02/2007 APPROVED LHITES
STORMWATER FINAL INSPECTION 10/25/2007 APPROVED DRANDALL
UTILITY COMPANY FINAL 10/25/2007 APPROVED CBOEHME
Note: Gravity ok.
INSULATION INSPECTION 06/21/2007 APPROVED JGIBSON
Note: THIS IS A REINSPECTION
INSULATION INSPECTION 06/20/2007 Disapproved -FEE REQUIRED JGIBSON
Note: MISSING FIRE BLOCKING @ SEVERAL AREAS IN FRONT OF HOUSE AND @ BACK BED ROOM.
GAS ROUGH 06/08/2007 APPROVED - AS NOTED JMCGOWEN
Note: INSTALL BOND CLAMP ON PIPE.CHECK ON INSULATION.
ALL ROUGH 06/08/2007 APPROVED JMCGOWEN
Note:
ALL ROUGH 06/01/2007 Disapproved -FEE REQUIRED JMCGOWEN
Note: 1)MISSING FIREBLOCKING....2)NEED TO TIGHTEN LOOSE NUTS AND TIGHTEN LOOSE THREADED RODS...3)2ND BED RM. REC. NEEDS TO BE 6` OFF DOOR.4)MISSING REC. IN FOYER..5)NEED TO CALL IN GAS ROUGH...
LATH /BRICK FLASHING 05/14/2007 APPROVED JGIBSON
Note: Dillard called to schedule a lath/brick flashing for 5/14/07
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/17/2007 APPROVED RMARVEL
Note: CALLED BY SIMONE
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 04/16/2007 Disapproved - NO FEE RMARVEL
Note: NOT READY.
LINTEL 03/21/2007 APPROVED JGIBSON
Note: THIS IS A REINSPECTION called insp Simone
LINTEL 03/20/2007 Disapproved -FEE REQUIRED RMARVEL
Note: need a revision showing less than 4in bearing on headers. rebar on top cell needs to be continuous. down cell rebar next to front window needsto be continuos to the footer.
FOUNDATION SURVEY APPROVED BY STORMWATER 03/19/2007 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 03/12/2007 APPROVED RMARVEL
FIRST ROUGH PLUMBING INSPECTION 03/08/2007 APPROVED JGIBSON
Note:

Review History

Department Status Date In Date Out
BLD COMPLETE 06/04/2007 06/04/2007
Note: Released By: LWOODROME Revision: Add gas to permit
BLD COMPLETE 03/20/2007 03/20/2007
Note: Released By: CCOTE Approved for Release. REVISION: Engineer letter regarding lintel bearing at front wall.
BLD COMPLETE 02/20/2007 02/21/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
BLD HOLD 02/19/2007 02/20/2007
Note: Held By: JJOSEPH The following items must be submitted in order to complete the Building Permit Application plan review. 1.The Residential System Sizing Calculation sheet was performed by an outdated version of the EnergyGauge software. Any version lower than 4.0 will not be accepted for either code compliance or system sizing. This software is definitely outdated and should be replaced with version 4.5. The ACCA Manual J is 7 in version 3.3 and WILL NOT be accepted any longer. Version 4.0 of the software has ACCA Manual J 8 and should be accepted as it is certified by ACCA as referenced in the current Florida Building Code. 2- Provide the mittered glass details.
URB COMPLETE 02/19/2007 02/23/2007
Note: Released By: JBEAUDET
ZON COMPLETE 02/16/2007 02/19/2007
Note: Released By: ECOYNE
SW1 COMPLETE 02/16/2007
Note: Released By: WKINELL

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADDITIONAL FEE ¤40.00 11/28/2007
ADDITIONAL FEE ¤40.00 11/28/2007
ADDITIONAL FEE ¤40.00 11/28/2007
ADDITIONAL FEE (¤40.00) 11/28/2007
ADDITIONAL FEE ¤40.00 11/28/2007
ADDITIONAL FEE (¤40.00) 11/28/2007
ADDITIONAL FEE ¤40.00 11/28/2007
ADDITIONAL FEE (¤40.00) 11/28/2007
ADDITIONAL FEE ¤40.00 11/28/2007
EARLY POWER INSPECTION ¤40.00 11/28/2007
EARLY POWER INSPECTION (¤40.00) 11/28/2007
EARLY POWER INSPECTION ¤40.00 11/28/2007
REINSPECTION FEE ¤40.00 11/28/2007
REINSPECTION FEE (¤40.00) 11/28/2007
REINSPECTION FEE ¤40.00 11/28/2007
REINSPECTION FEE (¤40.00) 11/28/2007
REINSPECTION FEE ¤40.00 11/28/2007
REINSPECTION FEE (¤40.00) 11/28/2007
REINSPECTION FEE ¤40.00 11/28/2007
REINSPECTION FEE ¤40.00 11/28/2007
REINSPECTION FEE ¤40.00 11/28/2007
REINSPECTION FEE (¤40.00) 11/28/2007
REINSPECTION FEE ¤40.00 11/28/2007
REINSPECTION FEE ¤40.00 11/28/2007
REVISION ¤40.00 11/28/2007
REVISION ¤40.00 11/28/2007
REVISION (¤40.00) 11/28/2007
REVISION ¤40.00 11/28/2007
REVISION (¤40.00) 11/28/2007
REVISION ¤40.00 11/28/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 03/07/2007
STORM WATER PERMIT FEES ¤80.00 03/07/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 03/07/2007
FIRE IMPACT FEE 4-1-06 ¤179.37 03/07/2007
MECHANICAL FEE ¤190.20 03/07/2007
PERMIT FEE ¤1,041.30 03/07/2007
PARKS IMPACT FEE 4/1/06 ¤1,159.02 03/07/2007
PLAN CHECK FEE ¤106.80 03/07/2007
PLUMBING FEE ¤190.20 03/07/2007
RADON FEE ¤18.62 03/07/2007
ADMIN FEE ¤20.00 03/07/2007
BUILDING CODE ADMIN FUND ¤18.62 03/07/2007
ELECTRIC FEE ¤190.20 03/07/2007
Fees Total Due: ¤0.00 Total Paid: ¤10,826.16