I want to search for...
Permit #2007020530
Permit Details
Status: COED
| Parcel Id: 07-11-31-7057-00490-0090 |
| CONDITIONED SPACE: 1908 sqft |
| GARAGE: 464 sqft |
| OPENED PORCH (WITH ROOF) : 200 sqft |
| OPENED PORCH (WITH ROOF) : 90 sqft |
| Total Square Footage: 2662 sqft |
| Block: 00490 |
| Subdivision: - |
| Job Phone: (386)775-4137 |
| Location Address: 9 UNICORN CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/25/2007 |
| NOC: RECORDED |
| Applicant name: GREGORY JOSEPH SEAL |
| Owner: MASTERPIECE HOMES IN |
|
Address 4721 E MODDY BLVE UNIT 5 BLDG 504 BUNNELL, FL 32110 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤136,015.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MASTERPIECE HOMES INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 740618 ORANGE CITY, FL 32763 |
CRC1327666 (Exp: 08/31/2010) | (386)775-4137 | (386)775-1397 |
Sub Contractors
JEFFREY JAY MITCHELL
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 353178 PALM COAST, FL 32135 |
CCC1327078 (Exp: 08/31/2010) | (386)437-3929 | (386)447-2236 |
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 1009 BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2014) | (386) 931-2568 | 386-313-3445 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 10/17/2007 | FINAL APPROVED | DROCKWELL |
| UTILITY COMPANY FINAL | 10/16/2007 | APPROVED | MBACON |
| Note: THIS IS A REINSPECTION 10/16 Gravity sewer ok. | |||
| STORMWATER FINAL INSPECTION | 10/15/2007 | APPROVED - AS NOTED | GLALIMA |
| Note: 24 ' FEET OF ROAD DAMAGE = $ 276.00 Road repaired, per GL, inspected 10/18/07.\\wk | |||
| UTILITY COMPANY FINAL | 10/11/2007 | Disapproved -FEE REQUIRED | MBACON |
| Note: THIS IS A REINSPECTION 4" Cleanout must be on your property. 2nd time for same problem. | |||
| RESIDENTIAL EARLY POWER | 10/09/2007 | APPROVED | LHITES |
| UTILITY COMPANY FINAL | 10/05/2007 | Disapproved -FEE REQUIRED | MBACON |
| Note: Gravity sewer clean out is on neighboring property, must be on your property. | |||
| DRIVEWAY | 09/12/2007 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| DRIVEWAY | 09/11/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| INSULATION INSPECTION | 08/30/2007 | APPROVED | DROCKWELL |
| ALL ROUGH | 08/28/2007 | APPROVED | DROCKWELL |
| ALL ROUGH | 08/27/2007 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: PLUMBING 2ND ROUGH NOT UNDER TEST PRESSURE/CLAMP GROUND WIRE TO ELECTRODES AT METER | |||
| LATH /BRICK FLASHING | 08/15/2007 | APPROVED | PGALLMANN |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 08/09/2007 | APPROVED - AS NOTED | DROCKWELL |
| Note: Provide solid support for post supporting porch roof framing/Remove 2x6 block under sheathing dining area look up | |||
| LINTEL | 07/30/2007 | APPROVED | DROCKWELL |
| FOUNDATION SURVEY APPROVED BY STORMWATER | 07/27/2007 | APPROVED | WKINELL |
| MONOLITHIC SLAB INSPECTION/SLAB | 07/20/2007 | APPROVED | DROCKWELL |
| FIRST ROUGH PLUMBING INSPECTION | 07/18/2007 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 05/17/2007 | 05/22/2007 |
| Note: Released By: LAPTEKAR received revised grading plan///inspection hold will be placed on permit until lot is cleared and erosion control measures in place. | |||
| SW1 | HOLD | 05/08/2007 | 05/10/2007 |
| Note: Held By: LAPTEKAR New lot grading submitted 5/8/07..grading plan needs to have all lot drainage directed to the front swale....the forward fall should start from the top of bank of the rear ditch...the ditch is to remain natural as it is....it appears to be a ditch on the city as builts for the neighboring wetland. The original lot grading plan intent was correct...the initial problem was the two proposed grades of 26.10 at the rear corners that needed to be removed so as not to bury the ditch. | |||
| SW1 | HOLD | 03/22/2007 | 03/23/2007 |
| Note: Held By: LAPTEKAR Received new detail plan. Received new lot grading plan?....changing the flow of the original grading plan....which was not the problem. The original grading plan's intent was correct, but the proposals of grade should start from the top of bank and fall forward.to the front swale. The original grading plan needed to remove the proposed 26.10 elevations from the rear lot corners in the ditch. The ditch elevations cannot be changed. | |||
| BLD | COMPLETE | 03/13/2007 | 03/14/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Fred R. | |||
| BLD | HOLD | 02/23/2007 | 02/26/2007 |
| Note: Held By: FREODICA 1. Exterior Finish. Indicate how the finish over wood framed walls will be provided and installed to comply with the Florida Building Code 2005 Supplement Section “R703.11 Weather Protection”. All wall surfaces that are not masonry or concrete shall be provided with weather protection per one of the approved building materials listed in Florida Building Code 2005 Supplement Table R703.11. Stucco, as indicated on the drawings, is acceptable if applied per ASTM C926 and the following criteria: i. Exterior Stucco shall be installed to prevent bonding to water resistive barrier per FRC, Section R703.2.1. ii. Exterior stucco shall be installed per ASTM C926; 3 coats with a minimum thickness of 7/8-inch per FRC, Section R703.6 & Table R703.11. iii. Installation of exterior lathing shall be installed to meet the requirements of ASTM C1063 per FRC, Section R703.6.2. The drawings indicate a cementituous coating. The Florida Building Code 2006 supplement section 1403.2 was modified to state “…that a weather-resistant exterior wall envelope shall not be required over concrete or non-porous masonry walls…” This means that, decorative cementituous coating CAN NOT, be used over exterior concrete or masonry walls, unless the they can be shown to be non-porous. Based on this information the drawings need to be revised to list one of the approved wall coverings per section R703.11 or testing must be provided showing that wall construction is non-porous. Stucco or Exterior Cement Portland Plaster are the acceptable terms from this code section. | |||
| ZON | COMPLETE | 02/22/2007 | 02/23/2007 |
| Note: Released By: ECOYNE | |||
| SW1 | HOLD | 02/26/2007 | |
| Note: Held By: LAPTEKAR Topo survey indicates a 10' ditch at rear property line....grading plan cannot change the elevation of this existing ditch..having site checked by an inspector. 2/28 per site inspection by BC...there is a ditch...the elevations of this ditch cannot be changed. Please submit a new lot grading plan. Driveway detail plan should incorporate company logo ...not a direct copy of the city sample. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 11/07/2007 |
| REINSPECTION FEE | ¤40.00 | 11/07/2007 |
| REINSPECTION FEE | ¤40.00 | 11/07/2007 |
| REINSPECTION FEE | ¤40.00 | 11/07/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 11/07/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 11/07/2007 |
| ADDITIONAL FEE | ¤40.00 | 07/26/2007 |
| ADMIN FEE | ¤20.00 | 05/25/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 05/25/2007 |
| BUILDING CODE ADMIN FUND | ¤13.31 | 05/25/2007 |
| ELECTRIC FEE | ¤144.00 | 05/25/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 05/25/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/25/2007 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 05/25/2007 |
| MECHANICAL FEE | ¤144.00 | 05/25/2007 |
| PERMIT FEE | ¤741.00 | 05/25/2007 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 05/25/2007 |
| PLAN CHECK FEE | ¤76.00 | 05/25/2007 |
| PLUMBING FEE | ¤144.00 | 05/25/2007 |
| RADON FEE | ¤13.31 | 05/25/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 05/25/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,340.84 |