I want to search for...

Permit #2007030143

Permit Details

Status: COED

Parcel Id: 07-11-31-7009-00220-0070
CONDITIONED SPACE: 3224 sqft
GARAGE: 560 sqft
OPENED PORCH (WITH ROOF) : 451 sqft
OPENED PORCH (WITH ROOF) : 113 sqft
Total Square Footage: 4348 sqft
Block: 00220
Subdivision: -
Job Phone: (386)445-9393
Location Address: 39 FALLEN OAK LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/11/2007
NOC: RECORDED
Applicant name: ANTONIO AMARAL JR
Owner: AMARAL CUSTOM HOMES

Address

13 UTILITY DRIVE

PALM COAST, FL 32137

Lot: 0070
Contracted Stated Job Value: ¤229,900.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

AMARAL CUSTOM HOMES INC.
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32135

CBC058062 (Exp: 08/31/2020) (386)445-9393 (386)446-0403

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 1963

Bunnell, FL 32110

ER0011613 (Exp: 08/31/2008) (386) 437-0607 (386)437-1847
RONALD E BANKS
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353741

PALM COAST, FL 32164

CAC049308 (Exp: 08/31/2010) (386) 437-4800 (386)445-0030
JAMES JOSEPH SAVNIK JR
Status Location Address State License Number Phone
CANCEL

1120 COUNTY RD 305

BUNNELL, 32110

CPC057381 (Exp: 09/30/2008) (386) 445-1253
ANTONIO JR AMARAL
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32137

CCC058004 (Exp: 08/31/2018) (386)445-9393 (386)446-0403

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 10/30/2007 FINAL APPROVED ACOOPER
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 10/26/2007 Disapproved -FEE REQUIRED JGIBSON
Note: GFCI N OT WORKING ON LANI, MISSING SHOCK ARRESSTOR ON DISHWASHER,DUCT WORK IN GARAGE DOES NOT MEET CODE SEE NOTES ON PLANS FIRST PAGE, MUST FILE FOR REVISION ON STAIR TREADS, MISSING EGRESS LIGHT AT FRONT ENTRY. MARK 931-2912
STORMWATER FINAL INSPECTION 10/25/2007 APPROVED DRANDALL
Note: 54 sf for public works, no damage for builder at this time
UTILITY COMPANY FINAL 10/24/2007 APPROVED TSCHWEERS
Note: Gravity ok, no permit to sign.
PRE DRIVEWAY 09/27/2007 CANCELLED BY INSPECTOR DRANDALL
Note: this already passed
RESIDENTIAL EARLY POWER 09/26/2007 APPROVED - AS NOTED LHITES
Note: CHECK SERVICE GROUND ROD: WILL CHECK AT FINAL
PRE DRIVEWAY 08/29/2007 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
PRE DRIVEWAY 08/27/2007 Disapproved -FEE REQUIRED DRANDALL
Note: sidewalk//a/c pad on right side of house too wide, cannot have flat work in 5' utility easement
INSULATION INSPECTION 07/06/2007 APPROVED RMARVEL
Note:
ALL ROUGH 07/02/2007 APPROVED - AS NOTED JGIBSON
Note: THIS IS A REINSPECTION CHECK PANEL @ INSULATION FOR GROUNDS SEPERATION ON BOOTOM MORE THAN 2 NOT PERMITTED.
ALL ROUGH 06/28/2007 Disapproved -FEE REQUIRED JGIBSON
Note: REMOVE UNRATED FOAM @ KIT. EXHUST AND REPLACE WITH RATED FOAM, INSTALL CHASE FOR ELECTRICAL TO ISLAND AND HAVE 2`` OF COVERAGE, FIRE BLOCK GUEST BATH DROP AND A/C CHASE UPSTAIRS
LATH /BRICK FLASHING 06/25/2007 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
LATH /BRICK FLASHING 06/18/2007 Disapproved -FEE REQUIRED JGIBSON
Note: MISSING TRANSITION JOINT BETWEEN MASONRY AND FRAME WALL.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 06/06/2007 APPROVED - AS NOTED CMINI
Note: NEED TO BLOCK AND NAIL VALLEY STRAPS IN MASTER BATH.
LINTEL 05/17/2007 APPROVED RMARVEL
Note:
FOUNDATION SURVEY APPROVED BY STORMWATER 05/11/2007 APPROVED WKINELL
MONOLITHIC SLAB INSPECTION/SLAB 05/02/2007 APPROVED ACOOPER
FIRST ROUGH PLUMBING INSPECTION 04/27/2007 APPROVED JGIBSON
Note:
R.O.W. DAMAGE INSPECTION 03/14/2007 APPROVED - AS NOTED DRANDALL
Note: P/W needs to refix 54 sq ft of road damage

Review History

Department Status Date In Date Out
BLD COMPLETE 06/19/2007 06/21/2007
Note: Released By: CCOTE Approved for Release. Review by Fred R. REVISION: Truss repair T13HT13, T12, T29.
BLD COMPLETE 04/04/2007 04/04/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
BLD HOLD 03/27/2007 03/29/2007
Note: Held By: JJOSEPH 1.Please provide beam connectors 2. IndicateTruss connectors to wood wall 3. Verify 1/2 inch plywood at the tile roof , typically 5/8
BLD HOLD 03/13/2007 03/14/2007
Note: Held By: JJOSEPH The beams size sheet must be signed and sealed.
BLD HOLD 03/09/2007 03/12/2007
Note: Held By: JJOSEPH 1- Provide the beam size (B1and B2) and Post connectors details (Uplift) or how the beams will be attached to bearing wall.
SW1 COMPLETE 03/08/2007 03/08/2007
Note: Released By: LAPTEKAR
ZON COMPLETE 03/06/2007 03/08/2007
Note: Released By: ECOYNE

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 10/30/2007
EARLY POWER INSPECTION ¤40.00 10/30/2007
REINSPECTION FEE ¤40.00 10/30/2007
REINSPECTION FEE ¤40.00 10/30/2007
REINSPECTION FEE ¤40.00 10/30/2007
REVISION ¤40.00 10/30/2007
STORMWATER REINSPECTION FEE ¤35.00 10/30/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 04/11/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 04/11/2007
STORM WATER PERMIT FEES ¤80.00 04/11/2007
ADMIN FEE ¤20.00 04/11/2007
ARC HOUSE REVIEW ¤125.00 04/11/2007
BUILDING CODE ADMIN FUND ¤21.74 04/11/2007
ELECTRIC FEE ¤217.20 04/11/2007
FIRE IMPACT FEE 4-1-06 ¤179.37 04/11/2007
MECHANICAL FEE ¤217.20 04/11/2007
PERMIT FEE ¤1,216.80 04/11/2007
PARKS IMPACT FEE 4/1/06 ¤1,159.02 04/11/2007
PLAN CHECK FEE ¤124.80 04/11/2007
PLUMBING FEE ¤217.20 04/11/2007
RADON FEE ¤21.74 04/11/2007
Fees Total Due: ¤0.00 Total Paid: ¤11,106.90