I want to search for...
Permit #2007030203
Permit Details
Status: COED
| CONDITIONED SPACE: 2867 sqft |
| GARAGE: 503 sqft |
| OPENED PORCH (WITH ROOF) : 355 sqft |
| OPENED PORCH (WITH ROOF) : 80 sqft |
| Total Square Footage: 3805 sqft |
| Block: 00270 |
| Subdivision: - |
| Job Phone: (386)931-0468 |
| Location Address: 10 WINTER HAVEN CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/28/2007 |
| NOC: RECORDED |
| Applicant name: ERIC ALLEN |
| Owner: MARCELINE & ZENAIDA REYES |
|
Address 39O MAHOGANY CT APR 606 PALATINE, IL 60067 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤292,000.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
ALLEN HOMES & CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone |
| CANCEL |
18 FORGE LANE PALM COAST, FL 32137 |
CGC1505654 (Exp: 08/31/2014) | 386-931-0468 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
RONALD E BANKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 353741 PALM COAST, FL 32164 |
CAC049308 (Exp: 08/31/2010) | (386) 437-4800 | (386)445-0030 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JEFFREY LUIS CARRASCO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
665 W. COUNTY ROAD 2006 BUNNELL, FL 32110 |
CCC1325557 (Exp: 08/31/2010) | 904-674-4730 | 904-268-0471 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 12/14/2007 | FINAL APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FINAL COMPLETE BUILDING INSPECTION | 12/13/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: NEED ARC SHIELD AND REPLACE MISSING COVER AT KITCHEN COUNTER, WEATHERPROOF COVER MISSING ON GFCI RECEPTACLE BY OUTSIDE PANEL, REAR PORCH CEILING IS NOT COMPLETE | |||
| UTILITY COMPANY FINAL | 12/11/2007 | APPROVED | PLAWRENCE |
| Note: THIS IS A REINSPECTION | |||
| STORMWATER FINAL INSPECTION | 12/07/2007 | APPROVED | DRANDALL |
| UTILITY COMPANY FINAL | 12/04/2007 | Disapproved - NO FEE | TSCHWEERS |
| Note: No Electric to Pep Panel. | |||
| RESIDENTIAL EARLY POWER | 11/28/2007 | APPROVED | LHITES |
| DRIVEWAY | 11/05/2007 | APPROVED | DRANDALL |
| INSULATION INSPECTION | 09/05/2007 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION | |||
| INSULATION INSPECTION | 08/31/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: FIRESTOP TOP PLATES MANY LOCATIONS, FIRE BLOCK AREAS WHERE THERE IS A CHANGE IN CEILING HEIGHTS BETWEEN ROOMS, FIRESTOP EXTERIOR WALLS WHERE NOTCHES HAVE BEEN MADE IN PERIMETER WOOD. | |||
| ALL ROUGH | 08/28/2007 | APPROVED - AS NOTED | MMOORE |
| Note: 1. NO FEE 2. FINISH THESE ITEMS BY INSULATION INSPECTION 3. WIRE OUT OF ROUGH-IN BOX 4. ADD 3 BOLTS ABOVE SLIDER / DRILL-INTO LINTEL 5. AT THIS AREA TIGHTEN ALL BOLTS 6. ACCESS OPENING FOR JACUZZI MOTOR TO BE FRAMED AT MOTOR 7. MASTIC DRYER AND MICROWAVE VENTS AT OSB | |||
| ALL ROUGH | 08/27/2007 | Disapproved - NO FEE | MMOORE |
| Note: 1. NO PLANS IN INSPECTION BOX | |||
| LATH /BRICK FLASHING | 08/02/2007 | APPROVED | JLEVRAULT |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/27/2007 | APPROVED - AS NOTED | CMINI |
| Note: MISSING TWO STRAPS AT FRONT WALL.....NEED FULL BEARING ON SHIMS AT REAR LINTEL. | |||
| LINTEL | 05/16/2007 | APPROVED | PGALLMANN |
| TUG ELECTRIC | 05/03/2007 | APPROVED | LHITES |
| Note: CALLED FPL 5/3 | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 04/26/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 04/19/2007 | APPROVED | PGALLMANN |
| Note: | |||
| FIRST ROUGH PLUMBING INSPECTION | 04/13/2007 | APPROVED | PGALLMANN |
| Note: |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 08/24/2007 | 08/28/2007 |
| Note: Released By: ECOYNE | |||
| BLD | CANCEL | 08/23/2007 | |
| BLD | COMPLETE | 03/26/2007 | 03/28/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| ZON | COMPLETE | 03/26/2007 | 03/28/2007 |
| Note: Released By: JGONZALEZ | |||
| SW1 | COMPLETE | 03/22/2007 | 03/22/2007 |
| Note: Released By: LAPTEKAR received revised topo surveys | |||
| ZON | HOLD | 03/13/2007 | 03/13/2007 |
| Note: Held By: ECOYNE need sample color of roof (apricot walls) | |||
| ZON | HOLD | 03/08/2007 | 03/09/2007 |
| Note: Held By: ECOYNE | |||
| SW1 | HOLD | 03/13/2007 | |
| Note: Held By: LAPTEKAR Need benchmark identified on topo survey. Need Lot 28 adjacent to rear lot line identified as vacant or improved(FFE). Swale elevation proposals? |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 12/14/2007 |
| REINSPECTION FEE | ¤40.00 | 12/14/2007 |
| REINSPECTION FEE | ¤40.00 | 12/14/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 03/28/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/28/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 03/28/2007 |
| ADMIN FEE | ¤20.00 | 03/28/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 03/28/2007 |
| BUILDING CODE ADMIN FUND | ¤19.03 | 03/28/2007 |
| ELECTRIC FEE | ¤205.20 | 03/28/2007 |
| FIRE IMPACT FEE 4-1-06 | ¤179.37 | 03/28/2007 |
| MECHANICAL FEE | ¤205.20 | 03/28/2007 |
| PERMIT FEE | ¤1,138.80 | 03/28/2007 |
| PARKS IMPACT FEE 4/1/06 | ¤1,159.02 | 03/28/2007 |
| PLAN CHECK FEE | ¤116.80 | 03/28/2007 |
| PLUMBING FEE | ¤205.20 | 03/28/2007 |
| RADON FEE | ¤19.03 | 03/28/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,824.48 |