I want to search for...

Permit #2007030641

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00320-0260
CONDITIONED SPACE: 3038 sqft
GARAGE: 467 sqft
OPENED PORCH (WITH ROOF) : 218 sqft
OPENED PORCH (WITH ROOF) : 76 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
Total Square Footage: 3849 sqft
Block: 00320
Subdivision: -
Job Phone: (386)445-8489
Location Address: 9 PRETORIA LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/18/2007
NOC: RECORDED
Applicant name: JAMES CARTWRIGHT HOPE
Owner: PORTEE HERMAN & TALITHA H&W

Address

52 BARKLEY LANE

PALM COAST, FL 32137

Lot: 0260
Contracted Stated Job Value: ¤300,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

Cornerstone Custom Homes, Inc. (Residential Contra
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 730384

Ormond Beach, FL 32173

CRC046828 (Exp: 09/30/2008) (386)439-2062 (386)439-2419

Sub Contractors

JOHN RENTON
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 1726

New Smyrna Beach, 32168

EC0002679 (Exp: 08/31/2014) (386)423-9314 (386)000-0000
RONALD E BANKS
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 353741

PALM COAST, FL 32164

CAC049308 (Exp: 08/31/2010) (386) 437-4800 (386)445-0030
THOMAS WALTER ALBANO
Status Location Address State License Number Phone Fax
INACTIVE

P. O. BOX 352075

Palm Coast, FL 32135

CFC045991 (Exp: 08/31/2024) 386-437-2795 (386)437-2781
JAMES CARTWRIGHT HOPE
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 730384

Ormond Beach, FL 32173

CRC046828 (Exp: 09/30/2008) (386)439-2062 (386)439-2419

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 02/05/2008 FINAL APPROVED ACOOPER
Note: THIS IS A REINSPECTION
FINAL COMPLETE BUILDING INSPECTION 02/04/2008 Disapproved -FEE REQUIRED JLEVRAULT
Note: requested by contractor
STORMWATER FINAL INSPECTION 01/31/2008 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
STORMWATER FINAL INSPECTION 01/30/2008 Disapproved -FEE REQUIRED GLALIMA
Note: Right rear side is draining to the rear. Back needs regrading. Remove concrete at end of driveway. Concrete cannot be used for road repair. 44 sq ft road damage.
UTILITY COMPANY FINAL 01/28/2008 APPROVED MBACON
Note: THIS IS A REINSPECTION
RESIDENTIAL EARLY POWER 01/25/2008 APPROVED LHITES
Note: THIS IS A REINSPECTION
RESIDENTIAL EARLY POWER 01/24/2008 Disapproved -FEE REQUIRED LHITES
Note: THIS IS A REINSPECTION MASTER CLOSET FLORESCENT LIGHT FIXTURE NEEDS MINIMUM OF 6" CLEARANCE HORIZONTALLY SHOULD NOT HAVE GROUND WIRE IN METER CAN. NEED ENGINEER DRAWINGS AND EXPLANATION FOR GROUND IN METER CAN
UTILITY COMPANY FINAL 01/24/2008 Disapproved - NO FEE TSCHWEERS
Note: No sod down yet.
PRE DRIVEWAY 01/17/2008 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION NEED TO BE 6'' UNDER CULVERT PIPE.
PRE DRIVEWAY 01/16/2008 Disapproved -FEE REQUIRED DRANDALL
Note: cut underlayment at road edge to a 90* cut, not a 45* [see pink paint]
RESIDENTIAL EARLY POWER 01/15/2008 Disapproved -FEE REQUIRED RMARVEL
Note: requested by contractor NEED ACCESS TO SPA TUB TO CHECK FOR HOOK UP. BOX OFF AND BLANK POOL FEEDER.
INSULATION INSPECTION 09/28/2007 APPROVED MMOORE
Note: THIS IS A REINSPECTION
INSULATION INSPECTION 09/26/2007 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION strap nm cable within 12in. of panel. all whit conductors being used as hots need to be marked as such.
INSULATION INSPECTION 09/10/2007 Disapproved -FEE REQUIRED ACOOPER
Note: STAPLE WIRING ABOVE ELECTRICAL BOXES, STRAP WIRING EVERY 4 1/2 FEET, ADD STEEL PROTECTION PLATES TO SHOWER PIPING (UPSTAIRS) TO AVOID DRYWALL SCREWS OR NAILS, INSULATION MISSING IN ARCH ABOVE STAQIRWELL, PLUMBER NOT FINISHED INSTALLING OUTSIDE SHOWER VALVE.
LATH /BRICK FLASHING 08/06/2007 APPROVED ACOOPER
ALL ROUGH 08/03/2007 APPROVED - AS NOTED ACOOPER
Note: STAPLE WIRING ABOVE ELECTRICAL BOXES, STRAP WIRING EVERY 4 1/2 FEET, ADD STEEL PROTECTION PLATES TO SHOWER PIPING (UPSTAIRS) TO AVOID DRYWALL SCREWS OR NAILS. WILL CHECK ON INSULATION INSPECTION.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/30/2007 APPROVED CMINI
Note: ROOF SHEATHING DEFICIENCIES TAKEN CARE OF.O.K. FOR ALL ROUGH.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/20/2007 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION NEED TO FILL EMPTY CELLS,TIGHTEN 1 THREADED ROD 2ND FL.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/06/2007 Disapproved -FEE REQUIRED CMINI
Note: NEED TO TIGHTEN THREADED RODS. NEED TO LOCATE LVL DETAIL. FLOOR JOIST 104 AND TRUSS T37 NEEDS TO HAVE BEARING POINTS ETABLISHED. NEED TO TIE IN BEARING WALL TOP PLATES TO INTERSECTING WALLS(STAIRWELL).
LINTEL 06/05/2007 APPROVED ACOOPER
Note:
FOUNDATION SURVEY APPROVED BY STORMWATER 05/24/2007 APPROVED WKINELL
TEMPORARY POLE 05/18/2007 APPROVED LHITES
MONOLITHIC SLAB INSPECTION/SLAB 05/10/2007 APPROVED CMINI
Note:
FIRST ROUGH PLUMBING INSPECTION 05/07/2007 APPROVED PGALLMANN

Review History

Department Status Date In Date Out
SW1 COMPLETE 01/10/2008 01/10/2008
Note: Released By: WKINELL Review revisions for walkways and circular driveway.\\wk
SW1 CANCEL 01/09/2008
ZON HOLD 09/13/2007 09/13/2007
Note: Held By: JGONZALEZ revision turn in to building for an outdoor shower. FR gave to zoning for review need outdoor shower on site plan wtih setback and dimension of concrete pad need to be shielded from public view with a privacy fence draw fencing on sheet and need color and material sheet to tell what type of fence being installed Jgonzalez Mr. Hope stated outdoor shower withdrawn at that location. 10/23/07
BLD COMPLETE 07/25/2007 07/26/2007
Note: Released By: CCOTE Approved for Release. Review by Fred R. REVISION: change front door to double door.
BLD COMPLETE 07/13/2007 07/18/2007
Note: Released By: FREODICA revisions submitted - Added skylight, deleted window; truss repair; revised energy calc. Released per LW.
BLD COMPLETE 06/01/2007 06/07/2007
Note: Released By: LWOODROME Revisions: threaded rod tie down locations and lintel from Lotts to Cast Crete
BLD COMPLETE 04/11/2007 04/12/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
ZON COMPLETE 04/11/2007 04/11/2007
Note: Released By: JGONZALEZ
SW1 COMPLETE 04/11/2007 04/11/2007
Note: Released By: LAPTEKAR Received new topo survey with grading plan adjusted.
ZON HOLD 03/27/2007 04/04/2007
Note: Held By: JGONZALEZ Need landscaping around corners of front of home Need to remove proposed pool from sealed survey and give correct setbacks from house need signed single family affidivate from homeowners
SW1 HOLD 04/04/2007
Note: Held By: LAPTEKAR 1.need two sealed topo surveys..there are no extras in the main file 2.grading plan needs to show all impervious drainage to the front swale, with a slope to the rear canal starting from the rear of the house not the side midway point.
ZON COMPLETE 01/09/2008
Note: Released By: BBARTON

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 02/04/2008
REVISION ¤40.00 01/31/2008
REVISION ¤80.00 01/31/2008
REVISION ¤40.00 01/31/2008
STORMWATER REINSPECTION FEE ¤35.00 01/31/2008
STORMWATER REINSPECTION FEE ¤35.00 01/31/2008
SW REVISION ¤40.00 01/31/2008
EARLY POWER INSPECTION ¤40.00 01/31/2008
EARLY POWER INSPECTION ¤40.00 01/31/2008
EARLY POWER INSPECTION ¤40.00 01/31/2008
REINSPECTION FEE ¤40.00 01/31/2008
REINSPECTION FEE ¤40.00 01/31/2008
REINSPECTION FEE ¤40.00 01/31/2008
REINSPECTION FEE ¤40.00 01/31/2008
REINSPECTION FEE ¤40.00 01/31/2008
ADMIN FEE ¤20.00 04/18/2007
ARC HOUSE REVIEW ¤125.00 04/18/2007
BUILDING CODE ADMIN FUND ¤19.25 04/18/2007
ELECTRIC FEE ¤210.00 04/18/2007
FIRE IMPACT FEE 4-1-06 ¤179.37 04/18/2007
MECHANICAL FEE ¤210.00 04/18/2007
PERMIT FEE ¤1,170.00 04/18/2007
PARKS IMPACT FEE 4/1/06 ¤1,159.02 04/18/2007
PLAN CHECK FEE ¤120.00 04/18/2007
PLUMBING FEE ¤210.00 04/18/2007
RADON FEE ¤19.25 04/18/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 04/18/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 04/18/2007
STORM WATER PERMIT FEES ¤80.00 04/18/2007
Fees Total Due: ¤0.00 Total Paid: ¤11,383.72