I want to search for...
Permit #2007040082
Permit Details
Status: COED
| Parcel Id: 07-11-31-7024-00370-0260 |
| CONDITIONED SPACE: 2920 sqft |
| GARAGE: 560 sqft |
| Total Square Footage: 3480 sqft |
| Block: 00370 |
| Subdivision: - |
| Job Phone: (904)296-1490 |
| Location Address: 11 PRESS WAY |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/31/2007 |
| NOC: RECORDED |
| Applicant name: KENNETH WAYNE CAMPBELL JR |
| Owner: MARONDA HOMES, INC |
|
Address 11200 ST. JOHNS INDUSTRIAL PKWY JACKSONVILLE, FL 32246 |
| Lot: 0260 |
| Contracted Stated Job Value: ¤115,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MARONDA HOMES INC. OF FLORIDA
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6800 SOUTHPOINT PKWAY SUITE 300 JACKSONVILLE, FL 32216 |
CBC058803 (Exp: 08/31/2018) | 904-268-7730 | 904-268-7740 |
Sub Contractors
HARRY DANIEL LONG JR
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
955 KELLIER ROAD ALTAMONTE SPRINGS, FL 32714 |
SUITE 1500 ALTAMONTE SPRINGS, FL 32714 |
EC0000726 (Exp: 08/31/2020) | (407)333-1500 | (407)320-1957 |
GARY CARMACK
| Status | State License Number |
| CANCEL | CAC043900 (Exp: 08/31/2010) |
JULIA H CREESE
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
927 CASCADES PARK TRAIL SANFORD, FL 32771 |
CFC1426702 (Exp: 08/31/2010) | (407)333-1509 | (407)320-1957 |
EUGENIA MAY MILHOLEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P. O. Box 2088 Bunnell, FL 32110 |
CCC048174 (Exp: 08/31/2010) | (386) 437-6457 | (386)437-6457 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL COMPLETE BUILDING INSPECTION | 09/28/2007 | FINAL APPROVED | ACOOPER |
| STORMWATER FINAL INSPECTION | 09/27/2007 | APPROVED | DRANDALL |
| Note: road repaired | |||
| STORMWATER FINAL INSPECTION | 09/26/2007 | APPROVED - AS NOTED | DRANDALL |
| Note: 24 sf road ROAD REPAIRED 9/27/07 | |||
| UTILITY COMPANY FINAL | 09/26/2007 | APPROVED | MBACON |
| Note: THIS IS A REINSPECTION | |||
| UTILITY COMPANY FINAL | 09/24/2007 | Disapproved - NO FEE | MBACON |
| Note: NO SOD. NO FINAL GRADE. ALSO NEEDS TO BE TELEVISED BY SEWER DEPT. | |||
| DRIVEWAY | 09/20/2007 | APPROVED | DRANDALL |
| Note: THIS IS A REINSPECTION | |||
| DRIVEWAY | 09/19/2007 | CANCELLED BY APPLICANT | DRANDALL |
| Note: THIS IS A REINSPECTION Cancel per Nathan due to rain | |||
| DRIVEWAY | 09/14/2007 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: washout.....swale stake is removed from right side and pipe is 50 percent full of water...need to reset and check elevations | |||
| UTILITY COMPANY FINAL | 09/13/2007 | Disapproved - NO FEE | TSCHWEERS |
| Note: FAILED NO SOD NO FINAL GRADE | |||
| RESIDENTIAL EARLY POWER | 09/04/2007 | APPROVED | LHITES |
| INSULATION INSPECTION | 08/06/2007 | APPROVED | JGIBSON |
| LATH /BRICK FLASHING | 08/06/2007 | APPROVED | JGIBSON |
| ALL ROUGH | 08/01/2007 | APPROVED | ACOOPER |
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/23/2007 | APPROVED - AS NOTED | ACOOPER |
| Note: Requested by contractor APPROVED AS NOTES: TURN IN COPIES FOR APPROVAL TO CITY AND POST THEM PRIOR TO NEXT INSPECTION. | |||
| ROOF SHEATHING/BRACES/TIES/ DOWN CELL | 07/19/2007 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: UNABLE TO REINSPECT WITH TYVEK IN PLACE. | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 07/17/2007 | Disapproved -FEE REQUIRED | ACOOPER |
| Note: SOME STAPLED AREAS ARE REDONE PROPERLY WITH NAILS, MANY ARE NOT. | |||
| EXTERIOR WALL SHEATHING/SHEAR WALL | 07/12/2007 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: staples have penetrated the sheathing too deep. | |||
| LINTEL | 07/06/2007 | APPROVED | CMINI |
| Note: | |||
| LINTEL | 06/29/2007 | Disapproved -FEE REQUIRED | CMINI |
| Note: STILL NEED TO REPLACE OR GET ENGINEERED LETTER ON MORTOR JOINTS BEING LARGER THAN 3/8"F.B.C. 21041.2.1 | |||
| LINTEL | 06/27/2007 | Disapproved -FEE REQUIRED | CMINI |
| Note: 1)NEED TO HAVE A UNIFORM 3/8" MOTOR JOINTS IN BLOCK WORK,F.B.C. 2104.1.2.1..MANY AREAS. 2)NEED TO HAVE A MIN. OF 25" LAP OF ALL BARS. 3)NEED TO DRILL UPRIGHT INTO CORRECT CELL AT FRONT DOOR WAY SO THAT THERE IS CORRECT COVERAGE AROUND REBAR. 4)NEED LETTER FROM LINTEL COMPANY STATING THAT BROKEN LINTEL OVER FRONT DOOR IS ACCEPTABLE. | |||
| FOUNDATION SURVEY APPROVED BY STORMWATER | 06/26/2007 | APPROVED | LAPTEKAR |
| MONOLITHIC SLAB INSPECTION/SLAB | 06/20/2007 | APPROVED | ACOOPER |
| FIRST ROUGH PLUMBING INSPECTION | 06/19/2007 | APPROVED | ACOOPER |
| Note: |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 08/14/2007 | 08/15/2007 |
| Note: Released By: LAPTEKAR Received new topo survey with revised elevations | |||
| SW1 | HOLD | 08/10/2007 | 08/10/2007 |
| Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are lower than expected by an average of 0.41ft. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised. | |||
| BLD | COMPLETE | 07/20/2007 | 07/24/2007 |
| Note: Released By: CCOTE Approved for Release. REVISION: Truus Repair 19-18-17. Overdriven fasteners. | |||
| BLD | COMPLETE | 07/06/2007 | 07/10/2007 |
| Note: Released By: LWOODROME revisions submitted: Masonry bed joint | |||
| BLD | COMPLETE | 06/29/2007 | 07/06/2007 |
| Note: Released By: LWOODROME Revision: Staples in lieu of nails and other connectors. | |||
| BLD | COMPLETE | 05/15/2007 | 05/22/2007 |
| Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba. | |||
| ZON | COMPLETE | 05/14/2007 | 05/15/2007 |
| Note: Released By: JGONZALEZ | |||
| ZON | HOLD | 05/03/2007 | 05/03/2007 |
| Note: Held By: JGONZALEZ plans are still not correct - page 3e state 10 X 18 Opt patio slab page WL1 has 10 X 30 flat screen porch in same location. | |||
| ZON | HOLD | 04/04/2007 | 04/10/2007 |
| Note: Held By: ECOYNE need plantings to wrap around corners of house 2' porch 10 X 18' on survey on plans shows screen porch 10 X 30' WL1 need 4 index trees plans are still not correct - page 3e state 10 X 18 Opt patio slab page WL1 has 10 X 30 flat screen porch in same location. resubmitted plant/tree schedule okay | |||
| SW1 | COMPLETE | 04/09/2007 | |
| Note: Released By: LAPTEKAR |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EARLY POWER INSPECTION | ¤40.00 | 09/28/2007 |
| REINSPECTION FEE | ¤40.00 | 09/28/2007 |
| REINSPECTION FEE | ¤40.00 | 09/28/2007 |
| REINSPECTION FEE | ¤40.00 | 09/28/2007 |
| REINSPECTION FEE | ¤40.00 | 09/28/2007 |
| REINSPECTION FEE | ¤40.00 | 09/28/2007 |
| REVISION | ¤40.00 | 09/28/2007 |
| REVISION | ¤40.00 | 09/28/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 09/28/2007 |
| STORMWATER REINSPECTION FEE | ¤35.00 | 09/28/2007 |
| SW REVISION | ¤40.00 | 09/28/2007 |
| 10/06 TRANS IMPACT FEE/MULTI | ¤3,631.83 | 05/31/2007 |
| ADMIN FEE | ¤20.00 | 05/31/2007 |
| ARC HOUSE REVIEW | ¤125.00 | 05/31/2007 |
| BUILDING CODE ADMIN FUND | ¤17.40 | 05/31/2007 |
| ELECTRIC FEE | ¤194.40 | 05/31/2007 |
| SCHOOL BOARD IMPACT FEE RES | ¤3,600.00 | 05/31/2007 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/31/2007 |
| FIRE IMPACT FEE RES 4/1/07 | ¤185.11 | 05/31/2007 |
| MECHANICAL FEE | ¤194.40 | 05/31/2007 |
| PERMIT FEE | ¤1,068.60 | 05/31/2007 |
| PARKS IMPACT FEE 4/1/07 | ¤1,196.11 | 05/31/2007 |
| PLAN CHECK FEE | ¤109.60 | 05/31/2007 |
| PLUMBING FEE | ¤194.40 | 05/31/2007 |
| RADON FEE | ¤17.40 | 05/31/2007 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,064.25 |