I want to search for...

Permit #2007040082

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00370-0260
CONDITIONED SPACE: 2920 sqft
GARAGE: 560 sqft
Total Square Footage: 3480 sqft
Block: 00370
Subdivision: -
Job Phone: (904)296-1490
Location Address: 11 PRESS WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/31/2007
NOC: RECORDED
Applicant name: KENNETH WAYNE CAMPBELL JR
Owner: MARONDA HOMES, INC

Address

11200 ST. JOHNS INDUSTRIAL PKWY

JACKSONVILLE, FL 32246

Lot: 0260
Contracted Stated Job Value: ¤115,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MARONDA HOMES INC. OF FLORIDA
Status Location Address State License Number Phone Fax
CANCEL

6800 SOUTHPOINT PKWAY SUITE 300

JACKSONVILLE, FL 32216

CBC058803 (Exp: 08/31/2018) 904-268-7730 904-268-7740

Sub Contractors

HARRY DANIEL LONG JR
Status Location Address Mailing Address State License Number Phone Fax
CANCEL

955 KELLIER ROAD

ALTAMONTE SPRINGS, FL 32714

SUITE 1500

ALTAMONTE SPRINGS, FL 32714

EC0000726 (Exp: 08/31/2020) (407)333-1500 (407)320-1957
GARY CARMACK
Status State License Number
CANCEL CAC043900 (Exp: 08/31/2010)
JULIA H CREESE
Status Location Address State License Number Phone Fax
CANCEL

927 CASCADES PARK TRAIL

SANFORD, FL 32771

CFC1426702 (Exp: 08/31/2010) (407)333-1509 (407)320-1957
EUGENIA MAY MILHOLEN
Status Location Address State License Number Phone Fax
CANCEL

P. O. Box 2088

Bunnell, FL 32110

CCC048174 (Exp: 08/31/2010) (386) 437-6457 (386)437-6457

Inspection History

Type Request Date Result Inspector
FINAL COMPLETE BUILDING INSPECTION 09/28/2007 FINAL APPROVED ACOOPER
STORMWATER FINAL INSPECTION 09/27/2007 APPROVED DRANDALL
Note: road repaired
STORMWATER FINAL INSPECTION 09/26/2007 APPROVED - AS NOTED DRANDALL
Note: 24 sf road ROAD REPAIRED 9/27/07
UTILITY COMPANY FINAL 09/26/2007 APPROVED MBACON
Note: THIS IS A REINSPECTION
UTILITY COMPANY FINAL 09/24/2007 Disapproved - NO FEE MBACON
Note: NO SOD. NO FINAL GRADE. ALSO NEEDS TO BE TELEVISED BY SEWER DEPT.
DRIVEWAY 09/20/2007 APPROVED DRANDALL
Note: THIS IS A REINSPECTION
DRIVEWAY 09/19/2007 CANCELLED BY APPLICANT DRANDALL
Note: THIS IS A REINSPECTION Cancel per Nathan due to rain
DRIVEWAY 09/14/2007 Disapproved -FEE REQUIRED GLALIMA
Note: washout.....swale stake is removed from right side and pipe is 50 percent full of water...need to reset and check elevations
UTILITY COMPANY FINAL 09/13/2007 Disapproved - NO FEE TSCHWEERS
Note: FAILED NO SOD NO FINAL GRADE
RESIDENTIAL EARLY POWER 09/04/2007 APPROVED LHITES
INSULATION INSPECTION 08/06/2007 APPROVED JGIBSON
LATH /BRICK FLASHING 08/06/2007 APPROVED JGIBSON
ALL ROUGH 08/01/2007 APPROVED ACOOPER
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/23/2007 APPROVED - AS NOTED ACOOPER
Note: Requested by contractor APPROVED AS NOTES: TURN IN COPIES FOR APPROVAL TO CITY AND POST THEM PRIOR TO NEXT INSPECTION.
ROOF SHEATHING/BRACES/TIES/ DOWN CELL 07/19/2007 Disapproved -FEE REQUIRED ACOOPER
Note: UNABLE TO REINSPECT WITH TYVEK IN PLACE.
EXTERIOR WALL SHEATHING/SHEAR WALL 07/17/2007 Disapproved -FEE REQUIRED ACOOPER
Note: SOME STAPLED AREAS ARE REDONE PROPERLY WITH NAILS, MANY ARE NOT.
EXTERIOR WALL SHEATHING/SHEAR WALL 07/12/2007 Disapproved -FEE REQUIRED JHINDMAN
Note: staples have penetrated the sheathing too deep.
LINTEL 07/06/2007 APPROVED CMINI
Note:
LINTEL 06/29/2007 Disapproved -FEE REQUIRED CMINI
Note: STILL NEED TO REPLACE OR GET ENGINEERED LETTER ON MORTOR JOINTS BEING LARGER THAN 3/8"F.B.C. 21041.2.1
LINTEL 06/27/2007 Disapproved -FEE REQUIRED CMINI
Note: 1)NEED TO HAVE A UNIFORM 3/8" MOTOR JOINTS IN BLOCK WORK,F.B.C. 2104.1.2.1..MANY AREAS. 2)NEED TO HAVE A MIN. OF 25" LAP OF ALL BARS. 3)NEED TO DRILL UPRIGHT INTO CORRECT CELL AT FRONT DOOR WAY SO THAT THERE IS CORRECT COVERAGE AROUND REBAR. 4)NEED LETTER FROM LINTEL COMPANY STATING THAT BROKEN LINTEL OVER FRONT DOOR IS ACCEPTABLE.
FOUNDATION SURVEY APPROVED BY STORMWATER 06/26/2007 APPROVED LAPTEKAR
MONOLITHIC SLAB INSPECTION/SLAB 06/20/2007 APPROVED ACOOPER
FIRST ROUGH PLUMBING INSPECTION 06/19/2007 APPROVED ACOOPER
Note:

Review History

Department Status Date In Date Out
SW1 COMPLETE 08/14/2007 08/15/2007
Note: Released By: LAPTEKAR Received new topo survey with revised elevations
SW1 HOLD 08/10/2007 08/10/2007
Note: Held By: EBLACKER We cannot complete the swale plan for this property due to a datum elevation discrepancy on the topographic survey. We check the topographic surveys against the city's as-built drawings corrected to the NAVD of 1988. The elevations are lower than expected by an average of 0.41ft. Please submit three signed sealed topographic surveys for this property showing corrected elevations. If we can be of help regarding this issue please call (386) 986-4760. NOTE: When topographic survey elevations are changed, all documents that reference or duplicate those elevations must also be revised.
BLD COMPLETE 07/20/2007 07/24/2007
Note: Released By: CCOTE Approved for Release. REVISION: Truus Repair 19-18-17. Overdriven fasteners.
BLD COMPLETE 07/06/2007 07/10/2007
Note: Released By: LWOODROME revisions submitted: Masonry bed joint
BLD COMPLETE 06/29/2007 07/06/2007
Note: Released By: LWOODROME Revision: Staples in lieu of nails and other connectors.
BLD COMPLETE 05/15/2007 05/22/2007
Note: Released By: CCOTE Approved for Release per plan cover sheet. Review by Auba.
ZON COMPLETE 05/14/2007 05/15/2007
Note: Released By: JGONZALEZ
ZON HOLD 05/03/2007 05/03/2007
Note: Held By: JGONZALEZ plans are still not correct - page 3e state 10 X 18 Opt patio slab page WL1 has 10 X 30 flat screen porch in same location.
ZON HOLD 04/04/2007 04/10/2007
Note: Held By: ECOYNE need plantings to wrap around corners of house 2' porch 10 X 18' on survey on plans shows screen porch 10 X 30' WL1 need 4 index trees plans are still not correct - page 3e state 10 X 18 Opt patio slab page WL1 has 10 X 30 flat screen porch in same location. resubmitted plant/tree schedule okay
SW1 COMPLETE 04/09/2007
Note: Released By: LAPTEKAR

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EARLY POWER INSPECTION ¤40.00 09/28/2007
REINSPECTION FEE ¤40.00 09/28/2007
REINSPECTION FEE ¤40.00 09/28/2007
REINSPECTION FEE ¤40.00 09/28/2007
REINSPECTION FEE ¤40.00 09/28/2007
REINSPECTION FEE ¤40.00 09/28/2007
REVISION ¤40.00 09/28/2007
REVISION ¤40.00 09/28/2007
STORMWATER REINSPECTION FEE ¤35.00 09/28/2007
STORMWATER REINSPECTION FEE ¤35.00 09/28/2007
SW REVISION ¤40.00 09/28/2007
10/06 TRANS IMPACT FEE/MULTI ¤3,631.83 05/31/2007
ADMIN FEE ¤20.00 05/31/2007
ARC HOUSE REVIEW ¤125.00 05/31/2007
BUILDING CODE ADMIN FUND ¤17.40 05/31/2007
ELECTRIC FEE ¤194.40 05/31/2007
SCHOOL BOARD IMPACT FEE RES ¤3,600.00 05/31/2007
STORM WATER PERMIT FEES ¤80.00 05/31/2007
FIRE IMPACT FEE RES 4/1/07 ¤185.11 05/31/2007
MECHANICAL FEE ¤194.40 05/31/2007
PERMIT FEE ¤1,068.60 05/31/2007
PARKS IMPACT FEE 4/1/07 ¤1,196.11 05/31/2007
PLAN CHECK FEE ¤109.60 05/31/2007
PLUMBING FEE ¤194.40 05/31/2007
RADON FEE ¤17.40 05/31/2007
Fees Total Due: ¤0.00 Total Paid: ¤11,064.25